Important Safety Instructions
⚠️ Important Safety Instructions: Read Before Installation
This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations.
- Make sure the power is turned OFF before installing or servicing this luminaire.
- WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain.
- This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
- Wiring connections must be made with UL listed wire connectors that are suitable for outdoor use.
- Position the low voltage wire and wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire or fitting.
- The main low voltage cable is intended for shallow burial - less than 6 inches (152 mm).
⚠️ Important Safety Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS.
- Turn off/unplug and allow to cool before replacing lamp.
- Lamp gets HOT quickly! Contact only switch/plug when turning on.
- Do not touch the hot lens, guard or enclosure.
- Keep lamp away from materials that may burn.
- Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
- Do not operate the luminaire fitting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
Product Details
Package Contents
- A. (1) Hat
Parts Sold Separately
- A. (1) Decorative Arm
Product Dimensions
The luminaire features a hexagonal hat with an 11-inch width and 3.5-inch height. The total fixture height is 22.15 inches. The base stake has a diameter of 9.6 inches. A note indicates the decorative arm is sold separately.
Diagram Description: A diagram shows the top view of the luminaire's hexagonal hat with a 9.6-inch diameter and the side view showing the hat's dimensions (11-inch width, 3.5-inch height) and the total fixture height of 22.15 inches. A note indicates that the decorative arm is sold separately.
Installation Steps
Step 1: Remove Stem Top
Loosen the stem top and remove it from the top end of the stem.
Diagram Description: A diagram illustrates loosening and removing the stem top from the stem.
Step 2: Install Decorative Piece (optional)
Place the decorative piece onto the top end of the stem as shown.
Diagram Description: A diagram shows the optional decorative piece being placed onto the top end of the stem.
Step 3: Install Lamp
Insert the lamp with the correct wattage and type marked on the fixture label and push firmly into place.
CAUTION: Do not exceed maximum wattage marked on fixture label.
Diagram Description: A diagram shows a lamp being inserted into the fixture's socket.
Step 4: Remove Washer and Finial
Loosen the finial and remove the finial, coupler, and washer from the stem top.
Diagram Description: A diagram shows the finial, coupler, and washer being loosened and removed from the stem top.
Step 5: Install Stem Top
Place the stem top over the lamp and thread the stem top onto the stem. Hand tighten until snug.
Diagram Description: A diagram shows the stem top being placed over the lamp and threaded onto the stem.
Step 6: Install Coupler to Hat
Thread the coupler onto the hat and hand tighten until snug.
Diagram Description: A diagram shows the coupler being threaded onto the hat.
Step 7: Install Hat
Thread the hat onto the stem top and hand tighten until snug.
Diagram Description: A diagram shows the hat being threaded onto the stem top.
Step 8: Install Stake
Determine the desired location for mounting the stake mount. Hammer the stake into the ground until the flange of the stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.
Diagram Description: A diagram illustrates hammering the stake into the ground until flush with the grade, with a board placed on top to prevent damage. The diagram also depicts the stake driven into the soil.
Step 9: Install Stem to Stake
Clear away an area in the ground at the wireway slot on top of the stake. Lay the luminaire pigtail into the wireway slot and secure the stem onto the stake. Tighten until snug.
Diagram Description: A diagram shows the stem being secured onto the stake, with the luminaire pigtail laid into the wireway slot.
Step 10: Wire Connection
Strip both leads from the luminaire. Using two wire connectors (sold separately), connect the leads from the fixture to the main supply cable leads.
Diagram Description: A diagram illustrates connecting the luminaire's pigtail leads to the main supply cable leads using wire connectors.
Maintenance
Install/Replace Bulb
Remove the hat and stem top to expose the lamp and replace it with the correct wattage and type marked on the fixture label. Then, reinstall the stem top and hat.
IMPORTANT: Lamps must be protected from moisture and dust at all times. Always reinstall the stem top and hat when removed.