AMP® Mini PinnaclePro Black Path & Area Light

Installation & Maintenance Guide

ITEM: APL-3017-4-B-BK

For assistance, call 1-813-978-3900 (Mon-Fri 9am-6pm EST) or email customersupport@amplighting.com.

IMPORTANT SAFETY INSTRUCTIONS: READ BEFORE INSTALLATION

This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage, and void the warranty.

These instructions do not cover all variations in installation, operation, maintenance, or mounting situations.

  • Ensure power is OFF before installing or servicing.
  • WARNING: Risk of electrical shock. Install luminaires 10 feet (3.05 M) or more from pools, spas, or fountains.
  • Use only with a power supply (transformer) rated a maximum of 300 watts (25 AMPS) at 15 volts.
  • Wiring connections must be made with wire connectors suitable for outdoor use.
  • Position the low voltage wire and wire connector within 6 inches (15.2 cm) of a building structure, luminaire, or fitting.
  • The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).
  • For additional lengths of low voltage cable, contact www.amplighting.com or call 1-813-978-3900.

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS: LIGHTED LAMP IS HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:

  • Turn off/unplug and allow to cool before replacing the lamp.
  • Lamps get HOT quickly! Handle only by the switch/plug when turning on.
  • Do not touch the hot lens, guard, or enclosure.
  • Keep the lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage the lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

SAVE THESE INSTRUCTIONS

PACKAGE CONTENTS

  • A. (1) Stem
  • B. (1) Fixture Body
  • C. (1) Stake
  • A. (1) MR11 Bulb

PRODUCT DIMENSIONS

The fixture has a total height of 26.2 inches. The head of the fixture extends 7.5 inches horizontally. The dimensions of the light-emitting part of the fixture are approximately 4.5 inches in height, 3.2 inches in width, and 2.7 inches in depth.

INSTALLATION STEPS

  1. REMOVE LENS AND GLARE GUARD
    Loosen the set screw and remove the glare guard from the lens. Remove the lens from the fixture body.
  2. INSTALL BULB
    Insert the MR11 bulb with the correct wattage and type marked on the fixture label. CAUTION: Do not exceed the maximum wattage marked on the luminaire label. NOTE: DO NOT touch the bulb with bare hands. Use a soft cloth to handle the bulb.
  3. INSTALL LENS AND GLARE GUARD
    Place the shield over the bulb and thread it onto the fixture. Attach the glare guard back onto the shield and secure it with the set screw.
  4. INSTALL STAKE
    Determine the desired location for mounting the fixture. Hammer the stake into the ground until the flange of the stake is flush with the grade. To avoid damage to the stake, place a board on top of the stake while hammering. NOTE: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.
  5. INSTALL FIXTURE
    Clear away an area in the ground at the wireway slot on top of the stake. Lay the luminaire pigtail into the wireway slot and attach the fixture onto the stake.
  6. WIRE CONNECTION
    Strip both leads from the luminaire pigtail. Using two wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads.
  7. ADJUST ANGLE OF FIXTURE
    Using an Allen Wrench, loosen the adjustment screws and modify the fixture body to the desired angle. Then tighten the adjustment screws.

INSTALL/REPLACE LAMP

Remove the glare guard and the lens to expose the MR11 lamp. Replace it with the correct wattage and type marked on the fixture label. Then, reinstall the lens and the glare guard.

IMPORTANT: The MR11 lamp must be protected from moisture and dust at all times. Always reinstall the lens and the glare guard when removed.

Specifications and product details are subject to change without notice. © Copyright 2023, AMP® Lighting, Lutz FL USA 33549. All rights reserved.

Models: APL-3017-4-B-BK Mini PinnaclePro Black Path and Area Light, APL-3017-4-B-BK, Mini PinnaclePro Black Path and Area Light, Black Path and Area Light, Area Light, Light

File Info : application/pdf, 8 Pages, 757.30KB

PDF preview unavailable. Download the PDF instead.

is-apl-3017-ver2

References

Adobe PDF Library 17.0 Adobe InDesign 18.3 (Windows)

Related Documents

Preview AMP Mini PinnaclePro Black Spotlight Installation & Maintenance Guide (AAL-1018-4-B-BK)
Comprehensive installation and maintenance guide for the AMP Mini PinnaclePro Black Spotlight (AAL-1018-4-B-BK) low voltage landscape lighting. Includes safety instructions, package contents, dimensions, and step-by-step installation procedures.
Preview AMP Lighting G2 ArchPro Path & Area Light APL-3031-B-BZ: Installation & Maintenance Guide
Comprehensive installation and maintenance guide for the AMP Lighting G2 ArchPro Path & Area Light (model APL-3031-B-BZ), covering safety, parts, dimensions, and step-by-step setup for low voltage landscape lighting.
Preview AMP TuscanPro Path & Area Light AHT-3517-B-BZ Installation and Maintenance Guide
Detailed installation and maintenance guide for the AMP Lighting TuscanPro Path & Area Light (Model AHT-3517-B-BZ). Learn how to safely install and maintain your low voltage landscape lighting.
Preview AMP G2 EcoPro Low Voltage Landscape Lighting Installation and Maintenance Guide
This guide provides detailed instructions for the installation and maintenance of the AMP G2 EcoPro Low Voltage Landscape Lighting system (Model AAL-1052). It includes essential safety warnings, package contents, product dimensions, and step-by-step procedures for setting up and adjusting the luminaire.
Preview AMP AWL-5012 Core Drill Well Light Installation and Maintenance Guide
Comprehensive installation and maintenance guide for the AMP AWL-5012 Core Drill Well Light, featuring safety instructions, parts list, dimensions, and step-by-step setup for low voltage landscape lighting.
Preview AMP Lighting LucidPro MR16 Spotlight Installation and Maintenance Guide
Comprehensive installation and maintenance guide for the AMP Lighting LucidPro MR16 Spotlight (AAL-1031-4-B-BZ), covering safety, parts, dimensions, and step-by-step setup.
Preview AMP Lighting MarinerPro LED Underwater Light Installation and Maintenance Guide
Installation and maintenance guide for the AMP Lighting MarinerPro LED Underwater Light (AUL-8000-34-B-BZ). Includes safety instructions, product dimensions, and wiring guidance.
Preview AMP Inline Microwave Motion Sensor VAC-MOTION4-PBK Installation and Maintenance Guide
This guide provides detailed instructions for installing and maintaining the AMP Inline Microwave Motion Sensor (Model VAC-MOTION4-PBK). It covers safety precautions, package contents, product dimensions, sensor settings adjustment, and step-by-step installation procedures for both single and multiple fixture setups within AMP Low Voltage Landscape Lighting systems.