Digital Programmable Thermostat
Models: T105, T105RF
Brand: SALUS Controls
Introduction
The SALUS T105/T105RF is a programmable, weekly thermostat designed to control room temperature in heating or cooling systems. It operates using AA 1.5V alkaline batteries. Please read this manual carefully before first use.
Product Compliance and Safety
This product complies with EU Directives: Electromagnetic Compatibility 2004/108/CE, Low Voltage Directive 2006/95/EEC, Directive 93/68/EEC and 99/5/EC. Visit www.saluslegal.com for full information. Use in accordance with national and EU regulations. For indoor use only. Installation must be carried out by a qualified person.
Technical Specifications
Wired Thermostat T105
Feature | Specification |
---|---|
Power Supply | 2 x AA batteries |
Rating Max | 5(3)A |
Outputs | Voltage-free NO/COM relay |
Temperature Range | 7 - 30°C |
Wireless Thermostat T105RF
Feature | Specification |
---|---|
Thermostat Supply | 2 x AA batteries |
Receiver Supply | 230 V AC 50 Hz |
Receiver Rating Max | 16(5)A |
Receiver Outputs | Voltage-free NO/COM relay |
Temperature Range | 7 - 30°C |
Installation and Placement
For optimal performance, the thermostat should be mounted on an internal wall, approximately 150 cm from the floor, away from direct heat sources, sunlight, or drafts.
[Diagram: Proper thermostat placement showing wall mounting at approximately 150 cm height, away from obstructions.]
LCD Icon and Button Functions
LCD Icons:
- [Day of the week indicator]
- [Clock] ⏰
- [Antifrost Mode] ❄️7°C
- [Low battery indicator] ?⬇️
- [Temperature unit] (°C/°F)
- [Room / setpoint temperature]
- [Program timeline indicator]
- [Program number]
- [Temporary override]
- [Eco Mode] ❄️
- [Comfort Mode] ☀️
- [Controlled device working status] (e.g., boiler active)
Buttons:
- [Increase] ⬆️
- [Decrease] ⬇️
- [Economic / Comfort Temperature] ☀️/❄️
- [LCD Backlight] ?
- [Temperature setpoint]
- [Weekly programming] ?️
- [Time set] ⏰
- [Restore factory settings] ?
Wiring Diagrams
T105 Wired Thermostat Wiring Diagram
This diagram shows connections for the T105 thermostat, including power input terminals (L, N) and output terminals (NO, COM) rated for a maximum of 5(3)A.
[Diagram: T105 wiring showing L, N, NO, COM terminals.]
T105RF Wireless Thermostat Wiring Diagram
This diagram illustrates the T105RF thermostat connected to the RXRT505 receiver. The receiver connects to 230V AC power and has output terminals (NO, COM) rated for a maximum of 16(5)A.
[Diagram: T105RF and RXRT505 receiver wiring showing thermostat battery power, receiver 230V AC power, and receiver NO/COM outputs.]
T105RF Wireless Communication Setup
Changing the Communication Code
To prevent interference with other wireless devices, it is recommended to change the communication code from the factory default. This is done using DIP switches numbered 1-5 located inside the thermostat. Ensure the DIP switches are set to the same position on both the transmitter (thermostat) and receiver. After changing the code, press the [RESET] ? button on the receiver.
Features and Operation
Auto-Adapt Feature
The Auto-Adapt function optimizes the heating device's operation to ensure the set comfort temperature is reached precisely on time. It activates only when the current room temperature is lower than the comfort temperature programmed for the upcoming period. The earlier activation time (between 10 and 50 minutes before the program starts) depends on the difference between the current and target temperatures.
Setting the Time
- Press the [Time set] ⏰ button. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to set the day of the week.
- Press the [Time set] ⏰ button again. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to set the hour.
- Press the [Time set] ⏰ button again. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to set the minutes.
- Press the [Time set] ⏰ button or wait 10 seconds for the time setting to be accepted.
Setting Economic / Comfort Temperature
- Press the [Economic / Comfort Temperature] ☀️/❄️ button. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to select the desired temperature. The display will show the current setpoint.
- To change the temperature, press the [Increase] ⬆️ or [Decrease] ⬇️ buttons.
- Press the [Economic / Comfort Temperature] ☀️/❄️ button or wait 10 seconds for the temperature setting to be accepted.
Programming
There are 9 available programs: Programs 1-6 are pre-set factory programs, while Programs 7-9 can be defined by the user.
Selecting Factory Programs (1-6)
- Press the [Weekly programming] ?️ button. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to choose how to program the days:
- Each day separately (1, 2, 3, 4, 5, 6 or 7)
- Business days and weekend (5+2)
- Whole week (7)
- Press the [Weekly programming] ?️ button again. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to select program 1-6 for the chosen day(s).
- Press the [Weekly programming] ?️ button to confirm the selection.
Choosing and Programming User Programs (7-9)
- Press the [Weekly programming] ?️ button. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to choose how to program the days:
- Each day separately (1, 2, 3, 4, 5, 6 or 7)
- Business days and weekend (5+2)
- Whole week (7)
- Press the [Weekly programming] ?️ button again. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to select program 7-9 for the chosen day(s).
- Press the [Weekly programming] ?️ button. Use the [Increase] ⬆️ or [Decrease] ⬇️ buttons to change the hours. Use the [Economic / Comfort Temperature] ☀️/❄️ button to assign a comfortable or economical temperature for the specified hour.
- Press the [Weekly programming] ?️ button to finish defining the program.
Antifrost Mode
To activate the 7°C Antifrost Mode (for heating mode only), simultaneously hold down the [Increase] ⬆️ and [Decrease] ⬇️ buttons. This mode will remain active until the next scheduled program change. To exit Antifrost Mode, press any button on the thermostat.
Service Parameters
Service parameters are adjusted using DIP switches located inside the thermostat.
DIP Switch Configuration:
- DIP Switch #3: Heating/Cooling Mode Selection
- Upper position (ON): Heating mode
- Lower position (OFF): Cooling mode
- DIP Switches #1 and #2: Span Control (Hysteresis)
DIP 1 DIP 2 Span ON ON 0.4°C OFF ON 0.8°C ON OFF 1.4°C OFF OFF 1.4°C