Salus Controls 091FL / 091FLRF Programmable Thermostat Quick Guide
Modelos: 091FL, 091FLRF
Date: 08/2018
Introduction
The 091FL / 091FLRF is a programmable, weekly thermostat used to control room temperature in heating or cooling systems. Before use, please read this manual carefully. Use only AA 1.5V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Product Compliance
This product complies with the following EU Directives:
- 091FL: 2014/30/EU, 2014/35/EU, 2011/65/EU
- 091FLRF: 2011/65/EU, 2014/53/EU 868.0 MHz - 868.6 MHz; <13dBm
Full information is available on the website www.saluslegal.com.
Safety Information
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Proper Thermostat Placement
Diagram description: Thermostat should be placed at a height of 150 cm, with a minimum distance of 20 cm from corners.
Technical Specifications
Wired thermostat 091FL | Wireless thermostat 091FLRF | |
---|---|---|
Power Supply | 2 x AA batteries | Thermostat: 2 x AA batteries Receiver: 230 V AC 50 Hz |
Rating max | 5 (3) A | Receiver: 16 (5) A |
Output | Voltage-free NO/COM relay | Receiver outputs: Voltage-free NO/COM relay |
Temperature range | 5 - 30°C | 5 - 30°C |
Button Functions
Button | Function |
---|---|
D | Set the day of the week |
H | Set the hour |
M | Set the minutes |
Temp | Comfort temperature or changing parameters (up) / Economic temperature or changing parameters (down) |
Prog | Weekly programming |
Prog # | Program selection |
OK | Confirm function |
Reset | Factory Reset |
LCD Icon Description
- Day of the week indicator
- Heating Mode ON
- Cooling Mode ON
- Room / setpoint temperature
- Temperature unit
- Controlled device working status (e.g., boiler)
- Temporary override
- Eco Mode
- Program number
- Antifrost Mode
- Comfort Mode
- Program timeline indicator
- Clock
- Low battery indicator
- AM/PM
Wiring Diagrams
091FL Wiring Diagram: Shows a thermostat (091FL) connected to a receiver (RXRT505) using L, COM, and NO terminals. The thermostat is powered by 2x AA batteries and has a rating of 5(3)A.
091FLRF Wiring Diagram: Shows a wireless thermostat (091FLRF) communicating wirelessly with a receiver (RXRT505). The receiver is powered by 230V AC 50Hz and has a rating of 16(5)A. Connections are shown using L, COM, and NO terminals for both the thermostat and receiver.
Changing the Communication Code of 091FLRF
Note: To prevent interference from other wireless devices, it is recommended to change the communication code from the factory setting.
- Use DIP switches (numbered 1-5) to change the communication code.
- Set DIP switches randomly – they need to be in the same position on both the receiver and the transmitter.
- Press the Reset button after changing the communication code.
Setting Time
- Press the OK button to highlight the display.
- Press D to set the day of the week.
- Press H to set the hour.
- Press M to set the minutes.
Setting the Comfort Temperature
- Press the OK button to highlight the display.
- Press the Temp button and then press the Temp button again to adjust the comfort temperature.
- To confirm, press the OK button.
Setting the Economic Temperature
- Press the OK button to highlight the display.
- Press the Temp button and then press the Temp button again to adjust the economic temperature.
- To confirm, press the OK button.
Programs
There are 9 programs available. Programs 0-5 are factory programs. Programs 6-8 can be defined by the user.
Selection of Factory (0-5) Programs
- Press the OK button to highlight the display. Select the day of the week by pressing the Prog button.
- Press Prog # to set the program number (0-5) for the selected day.
- Program 0 is a special program. It will set the thermostat to antifrost temperature (7°C) for the full day.
- To confirm, press the OK button.
Note: A label with program descriptions is sticking on the flip side of the cover.
Choosing and Programming User Programs (6-8)
- Press OK to highlight the display. Select the day of the week by pressing the Prog button.
- Press Prog # to set the program number (6, 7, or 8) for the selected day.
- Press the Temp button (either up or down) to move the timeline by one hour and assign the desired temperature (comfort or economic).
- To confirm, press the OK button.
Service Menu
Press the OK button to highlight the display. Then, hold the OK button for 5 seconds to enter the service menu.
- Mode Selection:
- Heating mode: The relay closes contacts when heating is needed (default).
- Cooling mode: The relay closes contacts when cooling is needed (with 5 minutes delay).
Press Temp (up or down) to select the mode. Confirm by pressing OK.
- Heating Device Delay Switch:
- Disabled (default setting).
- ON (5 min).
Select by pressing Temp (up or down). Confirm by pressing OK.
- Temperature Span Selection:
Possible values are 0.5°C or 1.0°C (default = 1.0°C). Press Temp (up or down) to set the span. Confirm by pressing OK.
- Measured Temperature Correction:
*Value range: -3.0°C to +3.0°C, default = 0.0°C. Press Temp (up or down) to set the correction. Confirm by pressing OK.
*This feature is available from software version 2.4.
Change Cooling / Heating Mode
This section title appears to be a summary for the mode selection within the service menu.
Changing Communication Code (091FLRF)
Note: To avoid interference from other wireless devices, it is recommended to change the communication code from the factory setting.
- Use DIP switches (numbered 1-5) to change the communication code.
- Set DIP switches randomly; they must be in the same position on both the receiver and the transmitter.
- Press the Reset button after changing the communication code.