General characteristics
Reference number | 60111810 / 60321110 / 60161610 / 60321610 / 60081812 / 60081112 / 60081612 / 60081813 / 60081114 / 60081614 / 60102215 / 60102205 / 60080199 / 60080198 |
Reference number (Eichrecht) | 60451810 / 60451110 / 60451610 |
Dimension H x W x D (mm) | 1400 x 220 x 240 |
Casing material | Steel 2,2 mm |
Standard colour | Body: Ral 6018 / Cover: Ral 9016 for 60451810 / 60081812 / 60081813 / 60102215 / 60102205 / 60080199 / 60080198 Body: Ral 7011 / Cover: Ral 9016 for 60111810 / 60321110 / 60451110 / 60081112 / 60081114 Body: Ral 9016 / Cover: Ral 9016 for 60161610 / 60321610 / 60451610 / 60081612 / 60081614 |
Steel treatment | Anti-corrosion (KTL) and powder coating |
Weight (kg) | 45 kg for 60451810 / 60451110 / 60451610 / 60081812 / 60081112 / 60081612 / 60081813 / 60081114 / 60081614 49 kg for 60111810 / 60321110 / 60161610 / 60321610 / 60102215 / 60102205 / 60080199 / 60080198 |
Number of charging points | 2 |
Socket | Type 2 |
Cable | Type 2 |
Electrical characteristics
Power output per socket | 0 to 22 kW for 60321110 / 60321610 / 60451810 / 60451110 / 60451610 / 60081812 / 60081112 / 60081612 / 60081813 / 60081114 / 60081614 / 60102215 / 60102205 0 to 11 kW for 60111810 / 60161610 / 60080199 / 60080198 |
Operating voltage (Ue) / Rates current (In A) for the charger | Single-phase cabling, phase + N 230V~ from 0 to 63A (determined at 20°C) Three-phase cabling, 3 phases + N 400V~ from 0 to 63A (determined at 20°C) |
Operating voltage (Ue) / Rates current (In A) per charge point | Single-phase cabling, phase + N 230V~ from 0 to 32A (determined at 20°C) Three-phase cabling, 3 phases + N 400V~ from 0 to 32A (determined at 20°C) |
Impulse voltage (Uimp) | 4kV |
Insulation voltage (Ui) | 230V single-phase 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Rated voltage | 1 phase + N: 230V – 3 phases + N: 400V |
Voltage tolerance (V) regardless of vehicle requirements | 195V - 265V |
Integrated protection system on charging station | Fuse type gG 63A |
Integrated protection system per charge point | Fuse type gG 32A + RCD 40A 30mA Type B |
Conditional short-circuit | 100kA IEC/EN 60898-1 |
Allowable thermal stress in Short Circuit | 16 000 A²s |
Connection to the mains | Phase/Neutral, rigid cable, 2.5 to 35 mm², screw terminals HO7 V R/U Earth, rigid cable, 2.5 to 35mm², screw terminals HO7 V R/U |
Type of load | Mode 3 charging terminal equipped with a locking system for Mode 3 |
Vehicle connection Mode 3 connector socket (60451810 / 60451110 / 60451610 / 60081812 / 60081112 / 60081612 / 60081813 / 60081114 / 60081614) | Type 2 3P+N (single-phase compatible) with pilots compliant with IEC 62191-1 and IEC 62196-2. Use only a manufacturer-approved plug with silver-plated contacts. Use of extension and adapter prohibited. |
Vehicle connection Mode 3 attache cable connector (60111810 / 60321110 / 60161610 / 60321610 / 60102215 / 60102205 / 60080199 / 60080198) | Type 2 3P+N (single-phase compatible) with pilots compliant with IEC 62191-1 and IEC 62196-2. Use of extension and adapter prohibited. 60080199 / 60080198: 4m curl 3x16A 60111810 / 60161610: 4m straight 3x16A 60321110 / 60321610 / 60102215 / 60102205: 8m straight 3x32A |
Phase rotation on channel 2 (Rightside). | In the case of monophase cabling (Ph+N) on the power source. Channel 2 will not be able to start charging sessions, until the phase rotation between contactor and socket are manually undone. |
AC meters | MID certified, Class B according to EN 50470-1, -3 |
Back office protocol | OCPP 1.6 Json |
Positioning | GPS |
Connectivity Ethernet | RJ45 connector for 60451810 / 60451110 / 60451610 / 60081813 / 60081114 / 60081614 / 60102215 / 60080199 |
Environment
Operating temperature | -25°C / +50°C |
Storage temperature | -25°C / +80°C |
Relative humidity | 0 to 90% without condensation |
Corrosivity class | C4 according to the IEC 9223 and IEC 12944 3C3/4C3 according to the IEC 60721-3 |
Protection rating | IP 54 (IEC 60529), IK 10 (EN 62262) Plugged in or not |
Vandalism resistence | IK10 |
Noise level | < 40 dBA at 1m |
Product | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation
Installation | Interior or exterior, limited access zone, intended for use by ordinary persons (DBO), assembly in cabinet (wall mounted), Pollution Degree 3, TNS, TT, compatible earthing system. In the event of an IT earthing system, this can be changed locally by adding an isolation transformer. |
Electrical safety | Class 1 IEC 61140 |
Electromagnetic compatibility
European standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
Radio technology type | GSM 2G/3G/4G, GPRS, RFID |
Suitable charging cards | Mifare, Ntag and iCODE SLI cards |
Ecotap B.V.
Kruisbroeksestraat 23
5281 RV Boxtel
+31(0) 411 210 210
info@ecotap.nl