Assembly Instructions for Designer Radiators

Introduction

Please read these instructions carefully before starting assembly.

The radiator must be installed by a qualified plumber or another competent specialist.

Note that the dimensions and panel-/pipe layout of the radiator may differ from the respective illustrations.

Do not dispose of the packaging until you have secured small parts such as wall brackets and mounting accessories.

We recommend wearing suitable protective clothing such as gloves and reinforced work shoes for assembly.

Required Tools

(not included in the delivery!)

Product Scope and Specifications

Scope of Use

The radiators are designed to be used in a closed central heating system.

Maximum Operating Pressure

Please note the maximum operating pressure specified in the assembly dimension table. Use above this level can damage the radiator and void any warranty.

Scope of Delivery

Standard Packaging Contents:

General Assembly Instructions

Typical Connection Options

Diagrams showing typical connection schemes for vertical and horizontal tube radiators, and for vertical and horizontal panel and profile radiators. These illustrate standard, offset/center, and side connections, often labeled with 'V' for valve and 'R' for return.

Assembly Diagrams

Diagram 1: Illustrates radiator mounting where brackets are positioned between the cross tubes. Shows dimensions H (height), B (width), X (horizontal bracket spacing), Y (vertical bracket spacing), and NA (distance from wall).

Diagram 2: Illustrates radiator mounting where brackets are positioned on the manifold. Shows dimensions H, B, X, Y, and NA.

Diagram 3: Shows two mounting methods: Vertical mounting with a bracket on the fixed bracket on the back; and Horizontal mounting. Both show dimensions H, B, X, Y, and NA.

Diagram 4: Shows radiators mounted on fixed pins with mounting sleeves, for both vertical and horizontal orientations. Shows dimensions H, B, X, Y, and NA.

Detailed Assembly Instructions

  1. If you use the supplied masonry wall plugs, use the dimensions for the main holes (see assembly dimension table) to drill 4 holes with a depth of approx. 60 mm and a diameter of 8 mm.
  2. Place the wall plugs (C) in the drilled holes (only in solid walls).
  3. Attach the screw (D) and washer (E) to the bracket for fixing to the wall. Be careful not to overtighten the screw.
  4. Some radiators are fitted with a baffle. These radiators will be marked with a sticker to advise the correct way up to install the radiator. To be sure you can look inside the horizontal tubes, the baffle will be visible and must be at the bottom. If both horizontal tubes are clear the baffle is not required on that type of radiator and the direction of installation is universal.
  5. Hang the radiator on the bracket.
  6. Mount the supplied air valve (A) and the blanking plug (B) in the upper threaded openings of the radiator.
  7. Connect the flow and return to the selected side of the radiator using radiator valves (not included). Seal the threads watertight. We recommend use of PTFE tape or similar sealing product on all connections. Leaks as a result of incorrect sealing are not covered under the warranty.
  8. How to first fill and vent the radiator:
    • Open the air vent [?].
    • Slightly open the inlet valve (about 10%) while leaving the outlet valve totally closed.
    • Allow the system to fill the radiator. If possible, fill without use of the heating pump; it is important that the radiator is filled slowly.
    • When the radiator has been filled, close the air vent [?].
    • Open both inlet and outlet valves totally and use the heating system for about 2 hours.
    • Totally close both inlet and outlet.
    • Open the air vent [?] and let out all air.
    This should clear all air from the radiator. If you are still having problems, on some systems it may be necessary to fit an automatic air vent.

Care and Use

Troubleshooting

General Radiators

Electric Radiators

Installation Dimension Tables

Bathroom Radiators

Model / label
(See packing)
Drill hole spacing horizontal "X"Drill hole spacing vertical "Y"Hub spacing (NA)Connection typeMax. Operating pressure in barAssembly diagram
PU / MT / P2O50 mmH - 220 mm50 mm50 mm connection44
PUE / MTE / P2OE50 mmH - 220 mm-electric44
MAG / K2DB - 55 mmH - 240 mmB - 30 mmdefault104
SC / HE / K3B - 300 mmH - 156 mm50 mmCenter connection101
FORS / NOPR / NESB - 50 mmH - 178 mmB - 50 mmdefault104
SD / PAR200 mmH - 180 mm50 mmCenter connection104
PAS / MAPR / P2B - 50 mmH - 220 mmB - 50 mmdefault44
PASD / MAPRD / P2DB - 200 mmH - 145 mmB - 50 mmdefault43
VE / SI / PUB - 30 mmH - 180 mm50 mmCenter connection104
FOU / NOT / FOO50 mmH - 178 mm50 mm50 mm connection104
CHA / KAL / CADB - 50 mmH - 140 mmB - 50 mmdefault44
CLC / CHG / C1B - 200 mmH - 196 mmB - 50 mmdefault101
CLC / CHG / C1 MAB - 200 mmH - 196 mm50 mmCenter connection101
VEL / CHGB / C2B - 200 mmH - 196 mmB - 50 mmdefault101
VEL / CHGB / C2 MAB - 200 mmH - 196 mm50 mmCenter connection101
RO / BAC / C3B - 120 mmH - 172 mmB - 50 mmdefault101
UR / VER / C4B - 30 mmH - 164 mmB - 30 mmdefault104
JAC / CEC / C5100 mmH - 124 mm50 mm50 mm connection51
SVC / PVC / C6B - 32 mmH - 120 mmB - 32 mmdefault54
SCC / PRC / C7B - 60 mmH - 300 mmB - 60 mmdefault54
BO / MA / C872 mmH - 168 mm72 mm72 mm connection104
SI / CEP / HE50 mmH - 124 mm50 mmCenter connection104
ZE / ROB - 160 mmH - 170 mmB - 30 mmdefault101
PO / FOB - 180 mmH - 165 mmB - 50 mmdefault101
LU / FI / K4B - 76 mmH - 180 mmB - 80 mmdefault104
LUE / FIE / K4EB - 76 mmH - 180 mm-electric104
POR / PRI / JOKB - 160 mmH - 223 mmB - 30 mmdefault101
PORE / PRIE / JOKEB - 160 mmH - 223 mm-electric101

Room Heaters

Model / label
(See packing)
Drill hole spacing horizontal "X"Drill hole spacing vertical "Y"Hub spacing (NA)Connection typeMax. Operating pressure in barAssembly diagram
FOR / NO / BRIB - 208 mmH - 100 mmH - 50 mmdefault103
FORD / NOD / BRIDB - 208 mmH - 200 mmH - 50 mmdefault103
FORH / NOH / BRIHB - 100 mmH - 163 mmB - 50 mmdefault103
FORDH / NODH / BRIDHB - 200 mmH - 178 mmB - 50 mmdefault103
FORM / NOM / BRIMB - 208 mmH - 105 mmH - 50 mmdefault103
FORMD / NOMD / BRIMDB - 208 mmH - 200 mmH - 50 mmdefault103
FORT / NOL / BRILB - 103 mmH - 50 mmH - 50 mmdefault102
SAT / AT / TAB - 80 mmH - 50 mmH - 50 mmdefault42
TA4 / AT4 / AT4B - 167 mmH - 50 mmH - 50 mmdefault42
SHW / HW / OXB - 250 mmH - 110 mmH - 50 mmdefault43
SHWD / HWD / OXDB - 250 mmH - 150 mmH - 50 mmdefault43
SHWDS / HWDS / OXDSB - 250 mmH - 150 mmH - 50 mmdefault43
SHWDHS / HWDHS / OXDHSB - 180 mmH - 220 mmB - 50 mmdefault43
SHWX / HWX / OXXB - 250 mmH-110 mmH - 50 mmdefault43
SHWDX / HWDX / OXDXB - 250 mmH - 150 mmH - 50 mmdefault43
SHWHX / HWHX / OXHXB - 142 mmH - 200 mmB - 50 mmdefault43
SHWDHX / HWDHX / OXDHXB - 180 mmH - 215 mmB - 50 mmdefault43
SHWP / HWP / OXPB - 250 mmH - 110 mmH - 50 mmdefault43
SHWPDX / HWPDX / OXPDXB - 250 mmH - 150 mmH - 50 mmdefault43
SHWM / HWM / OXMB - 175 mmH - 110 mmH - 50 mmdefault43
SHWE / HWE / OXEB - 250 mmH - 110 mmelectric43
SHWV / HWV / OXVB - 250 mmH - 110 mmH - 50 mmdefault43
SAUR / CH / TRB - 150 mmH - 50 mm50 mmcenter connection102
SAURD / CHD / TRDB - 150 mmH - 50 mm50 mmcenter connection102
SAURE / CHE / TRE204 mmH - 50 mm50 mmcenter connection102
SAURC / CHC / TRC182 mm from cornerH - 50 mm50 mmcenter connection102
SAURM / CHM / TRMB - 150 mmH - 50 mm50 mmcenter connection102
SAURCM / CHCM / TRCMB - 145 mmH - 50 mm50 mmcenter connection102
ES / SU / KAB - 100 mmH - 100 mmH - 100 mmdefault102
ESQ / SUS / KASB - 100 mmH - 100 mmH - 100 mmdefault102
DU / VU / ERB - 160 mmH - 100 mmH - 100 mmdefault102
DUV / VUQ / ERQB - 165 mmH - 100 mmH - 100 mmdefault42
SVIO / VIO / MI (H = 500)B - 200 mm375 mm450 mmdefault43
SVIO / VIO / MI (H = 650)B - 200 mm525 mm550 mmdefault43
DUE / VUE / EREB - 160 mmH - 100 mm-electric102
SHWHE / HWHE / OXHEB - 105 mmH - 220 mm-electric43
TIHE / GAHE / KIHEB - 300 mmH - 220 mm-electric101
FORHE / NOHE / BRIHEB - 100 mmH - 163 mm-electric103
STP / BUP / S1PB - 147 mmH - 104 mmH - 104 mmdefault102
TI22 / GA22 / KI22B - 85 mmH - 50 mmH - 50 mmdefault102
TID22 / GAD22 / KID22B - 85 mmH - 50 mmH - 50 mmdefault102
TIH22 / GAH22 / KIH22B - 200 mmH - 155 mmB - 50 mmdefault101
TIDH22 / GADH22 / KIDH22B - 230 mmH - 155 mmB - 50 mmdefault103
Models: 3887BTU, 3887BTU Fortuna Designer Radiator, Fortuna Designer Radiator, Designer Radiator, Radiator

File Info : application/pdf, 6 Pages, 650.81KB

PDF preview unavailable. Download the PDF instead.

pa 2671393 Microsoft Word 2019

Related Documents

Preview Ximax Designer Radiator Assembly and Installation Guide
Detailed assembly and installation instructions for Ximax Designer Radiators, covering setup, care, and troubleshooting. Includes essential information for proper installation and maintenance.
Preview Ximax Designer Radiator Installation and Assembly Guide
Official assembly instructions and installation guide for Ximax designer radiators. Covers setup, care, troubleshooting, and detailed dimensions for various models.
Preview Ximax Oceanus Designer Radiator Assembly Instructions and Installation Guide
Comprehensive assembly instructions and installation guide for Ximax Oceanus Designer Radiators, covering required tools, scope of delivery, general assembly steps, connection options, detailed diagrams, care and use, and troubleshooting.
Preview Ximax Designer Radiator Assembly and Installation Guide
Detailed assembly instructions and installation guide for Ximax designer radiators, covering parts, tools, general assembly steps, connection options, care, troubleshooting, and technical dimensions.
Preview Ximax Designer Radiator Assembly and Installation Guide
Comprehensive assembly and installation guide for Ximax designer radiators. Covers tools, parts, general instructions, connection options, diagrams, detailed assembly steps, care, and troubleshooting for various models.
Preview Ximax Fortuna Designer Radiator Assembly and Installation Guide
Comprehensive assembly and installation instructions for Ximax Fortuna Designer Radiators, covering preparation, installation steps, care, and troubleshooting. Includes detailed dimension tables for various models.
Preview Ximax Designer Radiator Assembly and Installation Guide
Comprehensive assembly and installation instructions for Ximax designer radiators, covering essential preparation, tools, parts, general assembly steps, connection options, care, and troubleshooting tips.
Preview Ximax Oceanus Designer Radiator Assembly and Installation Guide
Comprehensive assembly and installation instructions for Ximax Oceanus Designer Radiators, covering safety, parts, step-by-step assembly, care, troubleshooting, and detailed dimension tables for various models.