Autoslide M-229E Presence Curtain Sensor
Operation Instruction
1 Security Guide
! This device must use protective safety isolation low voltage, and adjustment or maintenance must be done by a professional installation contractor.
2 Product Overview
- 1 Decorative cap
- 2 Exposed cover
- 3 Master controller
- 4 Optical surface lens
- 5 LED indicator
- 6 Transmitter window
- 7 Receiver window
- 8 Wiring terminal
- 9 Function setting
- 10 Sensitivity Adjuster*
*Use 5mm flat head screwdriver to adjust detection range.
Caution Label must be facing outward!
3 Overall Characteristics
This curtain sensor is specially designed for automatic sliding doors to detect and keep safety. High accuracy.
Advanced infrared scanning technology. Stable and reliable.
Has function of background self-learn. Can learn background automatically when power on. Suits all kinds of occasions.
Always self-correcting once influenced by quake, distortion, move, dark and sunshine. Ensure the sensor can work durable.
4 Installation
Two ways of installation: on the top of the door or hidden in the ceiling.
Hidden in the ceiling or hidden in the ceiling.
On the top of the door
starting up: This Detector has function of background self-learning. After getting power on, red light will be always on. Please leave the detection area empty. After 6S, the background is learnt successfully.
Front view
Lateral view
5 Wiring Diagram of Input and Output
Power supply input: AC/DC 12-30V
Relay output: COM, NO, NC
Wiring: RED (Power+), GREEN (Power-), BLUE (COM), YELLOW (NO), ORANGE (NC)
6 Function Setting
Working mode: High sensitivity or low sensitivity
- High sensitivity: switch 1 up (Default setting is high sensitivity mode).
- Low sensitivity: switch 1 down. If the reflectance of working environment is strong, it should be set to low sensitivity to avoid self-induction or background mistaken.
Scanning Width:
- Width 78.74'/2000mm or 39.4'/1000mm
- Scan Width 78.74'/2000mm: switch 2 up. If the scan width is wide range, it should be set to 78.74'/2000mm.
- Scan Width 39.4'/1000mm: switch 2 down. If the scan width is narrow range, it should be set to 1000mm.
7 Detection Area
Note: presence detection area
starting up: This Detector has function of background self-learning. After getting power on, red light will be always on. Please leave the detection area empty. After 6S, the background is learnt successfully.
Front view
Lateral view
Note: Detection zone
Please keep the door closed before the sensor is in background self-learning process.
The debug person and any other objects such as ladder, tool kit must be out of the detection area when sensor is in the self-learning process.
The sensor will output door opening signal when an object is put within the detection area (as picture showed).
After 15s with no other objects or people enter, the sensor will regard that object as a part of background and the door will close back.
Remove the object, system will get back to the original background, output door open signal around 2S, and get back to standby system.
8 Attention
CAUTION
The scanning area is unidirectional, should be placed towards outside to the moving objects to avoid self-induction.
Ceiling installation: the sensor should keep ≥100mm from the door to avoid self-induction.
Exposed installation: The sensor should install in the door head. The distance between the bottom of the door head and the sensor should ensure 3.93'/100mm.
To adjust the angle, remove the main sensor from the cover's access, make sure the "Caution Sign" is facing outward before installing back the cover!
9 Technical Parameter
- Power output: AC/DC 12~30V (-/+10%)
- Type of ray: Infrared light modulation
- Photosource: Infrared 940mm
- Light beam: 8 channel transmit, 8 channel receive
- Quiescent current: 35mA
- Working current: 73mA
- Self-learn time: 15s
- Operating display: Standby: blue LED, Detecting: red LED
- Temperature range: -104 °F - 140 °F / -40 °C -60 °C
- Maximum installation: 2500mm/98.42'
- Maximum detection area: 78.7' / 2000mm (W) x 19.68' / 500mm (D)
- Hold-Up time: 500ms
- Response time: <100ms
- Changeover mode: High/Low sensitivity and FA/FB adjustable
- Signal output: Relay, 1 pair contact point optional
- IP: IP54
- Mechanical behavior: Maximum
- Connection: 0.04-0.2 inch² / 1-1.5 mm² 5pin terminal
- Shell: ABS
- optical surface: PMMA
- Installation: Exposed or Conceal
- Weight: about 0.32 Pound / 145g
- Dimension: Exposed 7.87'/200mm (L) x 1.9'/49mm (W) x 1.26'/32mm (H)