R. STAHL 8530/1-MCB-STA102-B20-000-2 Circuit Breaker
Article Number: 293919
Product Description
The R. STAHL 8530/1-MCB-STA102-B20-000-2 is a line protection circuit breaker designed for system technology. It offers good current limitation during short circuits and high switching capacities of 10, 15, or 25 kA, ensuring minimal load on lines and high selectivity to upstream fuses.
These components are modularly designed and available in 1 to 4-pole versions with nominal currents from 0.5–63 A. The maximum installation capacity is 4.5 partial units (UP).
Key Features
- Disconnecting function according to EN 60947-2
- Energy limitation class 3
- Easy replacement or extension of existing systems due to modular design
- Simple mounting by clipping onto a DIN rail in Ex e enclosures
- Fixed thermal-magnetic trip units
- Ergonomic operating lever for safe switching on and off
- Padlock protection (accessories) prevents re-operation during maintenance
Technical Characteristics
Explosion Protection
- Application Field (Zones): 1, 2
- Application Field (Zones) Note: Usable in Zone 21 / 22 with Ex tb / tc enclosure protection
- IECEx Certificate Gas: IECEx FMG 19.0029U
- IECEx Gas Explosion Protection: Ex db eb IIC Gb
- ATEX Certificate Gas: FM19ATEX0191U
- ATEX Gas Explosion Protection: II 2 G Ex db eb IIC Gb
- Certificates: ATEX (FM), Brazil (ULB), China (CQST), IECEx (FM)
- Certificate of Conformity: Certificate of conformity (ATEX)
Electrical Characteristics
- Rated Operational Voltage AC: 230/400 V
- Rated Service Current: 20 A
- Frequency: 50/60 Hz
- Rated Service Breaking Capacity: 10 kA
- Electrical Service Life: 2 x 10⁴
- Mechanical Service Life: 2 x 10⁴
- 1st Auxiliary Function: None
- Voltage 1st Auxiliary Function AC: -
- Current Max. 1st Auxiliary Function: -
- 2nd Auxiliary Function: None
- Max. Voltage 2nd Auxiliary Function DC: -
Tripping Characteristic
- Tripping Characteristic: B
- Number of Poles: 2 poles
Ambient Conditions
- Ambient Temperature: -40 °C ... 70 °C
- Ambient Temperature (Fahrenheit): -40 °F ... 158 °F
- Ambient Temperature Note: Ambient temperatures differing based on current certificates, upon request
Mechanical Characteristics
- Degree of Protection (IP) (IEC 60529): IP2X
- Housing Material: Thermoplastic
- Connection Terminal Minimum: 1.5 mm²
- Connection Terminal Maximum: 25 mm²
- Connection Terminal AWG Min: 16 AWG
- Connection Terminal AWG Max: 4 AWG
- Connection Terminal 2 Minimum: 1.5 mm²
- Connection Terminal 2 Maximum: 10 mm²
- Connection Terminal 2 AWG Min: 16 AWG
- Connection Terminal 2 AWG Max: 8 AWG
- Tightening Torque Minimum: 2 N·m
- Tightening Torque Maximum: 3 N·m
- Connection Terminal Note: For 2-conductor connection (upper and lower chamber simultaneously): Upper and lower chamber max. 16 / 10 mm² (Connection can be made with a maximum section difference between the upper and lower chamber).
- Allowed connection combinations: Refer to the operating manual for allowed connection terminal combinations.
- Width: 65 mm (2.56 in)
- Length: 165 mm (6.5 in)
- Mounting Depth: 138.3 mm (5.44 in)
- Weight: 1 kg (2.205 lb)
Mounting / Installation
- Tightening Torque: 2–3 N·m
- Tightening Torque (lbf-in): 17.7 ... 26.6 lbf-in
- Tightening Torque Auxiliary Contact: 0.4–0.6 N·m
- Tightening Torque Auxiliary Contact (lbf-in): 3.5 ... 5.3 lbf-in
Technical Drawings
Tripping Characteristic Curve: A graph displays the tripping characteristic curve, showing the multiple of the rated current (I/In) against time in seconds and minutes. It indicates the limit curve from a cold state for characteristic B.
Overall Dimensions: Diagrams show the overall dimensions of the circuit breaker in millimeters and inches. The unit is 65 mm (2.56 in) wide, corresponding to 2 division units. Other dimensions include height and depth.
Accessories
- Quadruple Locking Device: A locking/unlocking system that allows individual locking of the component using up to 4 cylinder locks. (Article No. 227232)
- Fixing Kit: A fixing kit for mounting the component onto a mounting plate without a DIN rail. (Article No. 276618)
- Cylinder Lock: For locking (shackle Ø 3). (Article No. 107115)
Disclaimer
Subject to technical modifications, dimensions, weights, construction types, and delivery possibilities. Figures are for indicative purposes only.