1 Cautions before Installation
(This may differ from the product specification.)
Installation Space
Ensure sufficient installation space in the bathroom and check that it does not obstruct the bathroom door.
- Secure water outlet at least 100mm [3.93in] away from the floor.
- Note: This can cause discoloration of the wall.
Diagram Description: A simple floor plan illustration showing the placement of the toilet, indicating 'Floor drain installation space' and 'Water Supply' connection point. It specifies the water outlet should be 100mm [3.93in] from the floor and the drain is positioned relative to the wall. An 'Offset flange' is mentioned as a potential solution if the rough-in is shorter than 11 inches.
Additional Notes:
- If you have a shorter rough-in than 11 inches, you can use an offset flange for installation.
- If you have a well water system, please contact VOVO USA before installation.
- Email: support@vovousa.com
Water Pressure
- Minimum 1.5 kgf/cm2 [0.15 MPa] water pressure is required. If the pressure is not secured, flushing may not work properly to discharge waste.
- Even when other modifiers are used simultaneously, the minimum required water pressure must still be maintained. The maximum water pressure is 7.5 kgf/cm2 [0.75 MPa].
Extract bad water before install:
- Direct the supply hose end into a 3 gallon [11.4L] or larger bucket.
- Ensure the supply stop can provide a minimum of 1.5 gallon [5.7L] or more in 10 seconds.
- Shut off the water supply.
[Proceed to next step] ➔
2 Drawing for Installation
(unit: mm | in)
Diagram Description: This section provides detailed dimensional drawings for various bidet toilet models. Side views are shown with measurements for height, width, and depth, along with specific model numbers associated with each set of dimensions. For example, one set of dimensions is 410/16.14in x 720/28.34in x 570/22.44in, corresponding to models PB-707S, PB-101S, TCB 9100WA, TCB 9100GA, TCB 9100W, TCB 9100G. Another set is 410/16.14in x 725/28.54in x 535/21.06in for models TCB 090SA, TCB 090S, RTB 090WA, RTB 090W, TC-090, TC-090W. A third set is 415/16.33in x 700/27.55in x 545/21.45in for TCB 8100B, TCB 8100W, TCB 8100N. A fourth set is 390/15.35in x 660/25.98in x 550/21.65in for TCB 8200SA, TCB 8200S, TCB 8200SA (Black), TCB 8200S (Black). The drawings highlight key dimensions like width, depth, and height, with specific measurements provided in both millimeters and inches.
3 FAQ
Q: What are the electrical requirements? Is it energy efficient?
A: 6-10 Amps at 120V, 60 Hz is necessary for this item. A separate circuit breaker is recommended. It has a power save mode which uses the least amount of energy.
Q: The power save LED light is flashing. (Turned off and on)
A: Please open the water valve, and check if water has entered the bidet. If it still flashes, please try a reset. To reset: Unplug the cord and plug it back in after 30 seconds. Ensure the seat and lid are open when resetting the bidet toilet.
Q: How long is the cord?
A: The cord is 4ft [1.2m] long.
4 Installation Accessories
1 A type Installation Accessories (Standard)
★Recommended installation method ★Requires installation by a plumber★
Diagram Description: This section shows the standard accessories included for Type A installation. It lists and visually depicts: Remote control (with a note that each product may use a different remote controller), AA Batteries (x3), Screws (x2), Anchors (x2), Wax Ring, and Ring Plate.
2 B type Installation Accessories
If Type A installation is inconvenient, please install Type B.
Diagram Description: This section shows the accessories for Type B installation, which is an alternative if Type A is not suitable. It lists and visually depicts: Remote control (again noting variations), AA Batteries (x3), Screws (x2), Anchors (x2), Wax Ring, Water Hose (Thicker, 1" x 5/8"), Water Shutoff Valve (1/2" x 5/8"), and Strainer Filter (5/8" x 5/8").
Common Accessories shown for both types:
- Remote control (various models listed: PB-707S, PB-101S, TCB 9100WA, TCB 9100GA, TCB 9100W, TCB 9100G, TCB 090SA, TCB 090S, RTB 090WA, RTB 090W, TC-090, TC-090W, TCB 8100B, TCB 8100W, TCB 8100N, TCB 8200SA, TCB 8200S, TCB 8200SA (Black), TCB 8200S (Black))
- AA Batteries (x3)
- Screws (x2)
- Anchors (x2)
- Wax Ring
- Ring Plate (for Type A)
- Water Pipe (for Type A)
- Water Shutoff Valve (1/2" x 5/8")
- Strainer Filter (5/8" x 5/8")
- Water Hose (Thicker, 1" x 5/8") (for Type B)
- Water Hose (Thin, 1" x 1/2") (for Type B)
- Conversion Nut (to fit water shutoff valve)
- Rubber Washer
5 Installation
(This may differ from the product specification.)
① A type Installation (Standard)
Steps:
- Close the water gauge [water shutoff valve].
- Remove dust and sand from the water inlet when installing the shutoff valve.
- Wrap Teflon tape around the water pipe.
- Connect the pipe with the shutoff valve.
- Connect the Strainer Filter.
[Incorrect connection example shown with a 3/8" pipe]
Diagram Description: Illustrations show the process of connecting the water shutoff valve, applying Teflon tape to the pipe threads, and attaching the strainer filter to the water supply line.
② B type Installation Accessories
Steps:
- Attach the provided water hose to your water shutoff valve.
Diagram Description: Shows connecting a water hose (labeled 3/8") to a water shutoff valve (labeled 1/2" x 5/8"). A conversion nut is illustrated as potentially needed to bridge the size difference.
③ How to install the Ceramic
Steps:
- Apply weight evenly. Do not move after placement, as the water-tight seal may break.
- A team of two people is recommended to correctly place the toilet base.
Diagram Description: Illustrations show placing the ceramic toilet base onto the floor, emphasizing the need for even weight distribution and stability. It also depicts the 'fixing hook' on the toilet and the corresponding 'fixing hook' on the bidet.
④ Connect Hose
- Insert the brass part [brass part] into the flushing outlet first.
- Turn the hose nut clockwise to tighten the hose.
Diagram Description: Shows inserting the brass fitting into the toilet's flushing outlet and then connecting and tightening the water hose using the hose nut.
⑤ Connect Bidet to Toilet
- Assemble the toilet with bidet, jet spray outlet, and bowl washing outlet.
- Insert the hose into the filter.
- Insert the bidet's fixing hook onto the toilet's fixing hook until it makes a 'click' sound.
Diagram Description: Illustrates the bidet unit being attached to the toilet bowl. It shows the connection points for the jet spray outlet and bowl washing outlet, the hose insertion into a filter, and the engagement of the fixing hooks. It also shows the 'A type (Standard)' and 'B type' bidet configurations with their respective fixing hooks.
⑥ Open the water valve
Steps:
- Using a screwdriver, turn the shutoff valve clockwise to reduce the water pressure if necessary.
- Turn the shutoff valve clockwise to open the water supply.
Diagram Description: Shows a hand turning a water shutoff valve clockwise with a screwdriver, indicating the action to open the water supply.
Note: The water may overflow from the rim when cleaning the bowl in regions with high water pressure. Use a screwdriver to turn the shutoff valve clockwise to reduce water pressure.
⑦ Connect Power
Steps:
- Please plug in the power only after completing all installation and opening the water valve.
- Press the flush button. Water will fill the ceramic bowl. [full flush]
Diagram Description: Shows the power cord being plugged into an electrical outlet. It also depicts pressing the flush button on the bidet, with an indication that water will fill the bowl.