Polycom RealPresence Collaboration Server (RMX) 1800 Hardware Guide

Version 8.4 | June 2014 | 3725-69957-004/A

Hardware Description

This Hardware Guide provides information on the RealPresence Collaboration Server 1800 and its components.

[Note: Illustrations in this book are for your reference only and may not accurately depict the actual system.]

Main Features

The Polycom RealPresence Collaboration Server 1800 offers the following features:

  • Linux® based
  • Support for standard network ports (H.323, SIP, and LAN)
  • New hardware codec technologies
  • Up to 1080p 60 high definition video conferencing
  • Telecommunication grade high availability and on-line upgrading
  • Easy integration of conference elements into external network management
  • Enhanced Continuous Presence (multi-image video)
  • IVR (Interactive Voice Response) module
  • Support both H.264 SVC endpoints-only conferencing, and AVC-SVC mixed conferencing.
  • Hot backup to offer high availability and a rapid recovery solution

System Specifications

The following table lists technical specifications of the RealPresence Collaboration Server 1800 system.

Physical

Physical Specifications
AttributeValue
Height2U (8.9 cm.)
Width17.36" (44.1 cm.)
Depth19.13" (48.6 cm.)
WeightUp to 14.5 Kg (31.97 lbs)

Media Protocols

Media Protocols Supported
TypeProtocols
AudioSAC, G.711, G.722.x, G.729A, Siren 14, Siren 22 (in mono or stereo) and Siren LPR.
VideoH.261, H.263, H.263+, H.264, H.264 High Profile, H.264 SVC

Network ports

Network Port Specifications
TypePorts
IPH.323, SIP
LANLAN 1, LAN 2

Power Supply

Power Supply Specifications
AttributeValue
AC Input/ Range, Power outputVoltage range: 100-240 VAC 50-60 Hz.
Current: 10-3.5 AMP
Maximum power output: 740 Watts.

Power Consumption

Power Consumption
AttributeValue
AC Maximum Power consumption350 Watts.

Environment

Environmental Specifications
AttributeValue
Operating temperature10° to 35°C (50° to 95°F).
Storage temperature-40° to 70°C (-40° to 158° F).
Relative humidity20% to 90% non-condensing.
Operating altitudeUp to 5 KM (16404 Ft.)
Operating ESD4 KV.

Conferencing Capacities

The following table summarizes the different system capacities.

System Capacities
System FunctionsNumber
Maximum number of Video participants in a conference150
Maximum number of Audio-only participants in a conference300
Maximum number of Audio calls per second5
Maximum number of Video calls per second2
Maximum number of conferences200
Maximum number of Meeting Rooms1000
Maximum number of Entry Queues40
Maximum number of Profiles80
Maximum number of Conference Templates100
Maximum number of SIP Factories40
Maximum number of IP Services2
Maximum number of IVR Services80
Maximum number of Recording Links20 (Default)
Maximum number of IVR Video Slides150
Maximum number of Log Files (1Mb max.)4000
Maximum number of CDR Files2000
Maximum number of Fault Files1000
Number of Participant alertsNo limitation
Maximum number of concurrent RealPresence Collaboration Server 1800 Web Client connections to the MCU20
Maximum number Address Book entries4000
Maximum number of Users100
Maximum number of Reservations (internal Scheduler)2000

Resource Capacity

The RMX 1800 system allocates port resources in AVC HD720p30 units. The number of unit ports each type of call requires differs for AVC-SVC mixed conferences and non-mixed conferences.

Listed are the resource capacities for different system configurations, licenses, and conferencing modes.

Resource Capacity in Non-Mixed Conferences

The port consumption of different calls are as shown in this table.

Port consumption of different calls, in non-mixed conferences
720p 301080p 601080p 30SDCIFAudioSVC
1421/21/21/31/3

In other words, to make a 1080p 60 call, you need four license ports; to make a 1080p 30 call, two license ports; and so forth.

When the required resource is not a whole number, it's rounded up to the nearest whole number. For example, to make an SVC call requiring 1/3 of a license port, one port will be allocated.

The following table lists the system capacities for each license in non-mixed conferences when the system has one DSP card.

Licensed capacity for systems with three DSP cards, in non-mixed conferences
Licensed ports1080p 601080p 30AVC HDAVC SDAVC CIFAudioSVC
512510101515
10251020203030
15371530304545
205102040406060
256122550507575
307153060609090
35817357070105105
401020408080120120
451122459090135135
50122550100100150150
55132755110110165165
60153060120120180180
65163265130130195195
70173570140140210210
75183775150150225225
Licensed capacity for systems with one DSP card, in non-mixed conferences
Licensed ports1080p 601080p 30AVC HDAVC SDAVC CIFAudioSVC
512510101515
10251020203030
15371530304545
205102040406060
256122550507575

Resource Capacities in Mixed Conferences

The port consumption of different calls in mixed conferences are shown in the following table.

Port consumption of different calls, in mixed conferences
720p 301080p 30SDCIFAudioSVC
3/233/43/41/31/3

In other words, to make a 1080p 30 call, you need three license ports. When the required resource is not a whole number, it's rounded up to the nearest whole number. For example, to make an SVC call requiring 1/3 of a license port, one port will be allocated.

The following table lists the system capacities for each license in mixed conferences when the system has 3 DSP cards.

Licensed capacity for systems with three DSP cards, in mixed conferences
Licensed ports1080p 30AVC HDAVC SDAVC CIFAudioSVC
513661515
103613133030
1551020204545
2061326266060
2581633337575
30102040409090
3511234646105105
4013265353120120
4515306060135135
5016336666150150
5518367373150150
6020407575150150
6521427575150150
7023427575150150
7525427575150150

The following table lists the system capacities in non-mixed conferences when the system has one DSP card.

Licensed capacity for systems with one DSP card, in mixed conferences
Licensed ports1080p 30AVC HDAVC SDAVC CIFAudioSVC
513661515
103613133030
1551020204545
2061326265252
2581426265252

Note: About special licenses

For both mixed and non-mixed conferences, special licenses are available to provide up to 100 ports for systems configured with three DSP media cards, or up to 35 ports for systems with one DSP card.

For more information, please contact your local Polycom representative.

Install the RealPresence Collaboration Server 1800

This section describes site requirements and system installation procedures.

Site Requirements

This section describes the requirements your site must meet for safe installation and operation of the system.

Safety Requirements

For your protection, please read these safety instructions completely before operating the equipment.

  • Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth.
  • Locate the main circuit breaker within the room.
  • Locate the emergency power OFF switch within the room.
  • Never assume that power is disconnected from a circuit.
  • Use only the power cord supplied with the system.
  • The power cord should only be connected to a power outlet that has a protective ground contact.
  • Ensure that the power cord is easily accessible from the back of the system at all times.
  • Place the equipment in a well-ventilated area where the vents are free from obstruction.
  • Do not place heavy objects directly on top of the RealPresence Collaboration Server 1800 unit.
  • Do not use liquids around your equipment.

Shelf Mount Safety Precautions

The following precautions should be followed with regards to rack mount safety:

  • Keep the area around the RealPresence Collaboration Server 1800 clean and free of clutter.
  • Decide on a suitable location for the equipment rack that will hold the RealPresence Collaboration Server 1800 unit. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet.
  • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
  • Install the heaviest components on the bottom of the rack first, and then work up.
  • Allow the power supply units to cool before touching them.

Installation Precautions

When handling electronic components, standard anti-static precautions must be observed:

  • Wear a grounding strap
  • Keep components in anti-static bags, when not installed in the RealPresence Collaboration Server 1800.
  • The number of power units (maximum two, default one) varies by your product package.

The following precautions should be followed with regards to installation of the RealPresence Collaboration Server 1800:

  • Use a regulating uninterruptable power supply (UPS) to protect the RealPresence Collaboration Server 1800 from power surges and voltage spikes, to keep your MCU operating in case of a power failure.
  • Place the RealPresence Collaboration Server 1800 on a hard, flat surface such as a desktop or mount it on 19" rack.
  • The airflow of the RealPresence Collaboration Server 1800 is from front to back. Be sure that the areas in the front and rear side of the system are clear for proper ventilation.

[Caution: Sealed System! The RealPresence Collaboration Server 1800 is a sealed system, breaking the seal and opening the chassis VOIDS the WARRANTY!]

Install the RealPresence Collaboration Server 1800

The following procedures have to be performed to install the RealPresence Collaboration Server 1800 in your site:

  • Unpacking the system
  • Installing the system in a rack or as a standalone system
  • Connecting the system to the power source
  • Connecting the network (LAN and IP) cables to the system

To unpack and lift the RealPresence Collaboration Server 1800:

  1. When you receive the RealPresence Collaboration Server 1800 packing case, inspect the equipment for damage and verify that the components match the packing slip.
  2. Open the top cover of the packing case. Boxes are placed on the top Stratocell® and contain power cables, 2 ethernet cables, USB key and documentation.

Write down the system's serial number that is on a sticker on the back of the unit. It will be needed for product registration later in the process.

Make sure that boxes contain all the required parts.

Mount the RealPresence Collaboration Server 1800 on a Shelf

Follow the steps below to mount the system on a shelf.

  1. Install the shelf supplied by the rack manufacturer, in the rack.
  2. Mount the system on the shelf.
  3. Fasten the system to the rack with screws through the four holes in the system's front mounting brackets.

Connect the RealPresence Collaboration Server 1800 to a Power Source

The following restrictions apply to the conductors and connectors that may be used to ground the unit when rack mounted:

  • When using bare conductors, they must be coated with an appropriate antioxidant compound before crimp connections are made. Tinned, solder-plated or silver-plated connectors do not have to be prepared in this manner.
  • The same bolt assemblies should not secure multiple connectors.
  • Listed fastening hardware must be compatible with the materials being joined and must be preclude loosening, deterioration and electrochemical corrosion of the hardware and joint materials.

Connect the RealPresence Collaboration Server 1800 to AC Power

[Power] Only the AC Power cable supplied by Polycom should be used.

The size of the protective earthing conductor should be a minimum of 10 AWG.

The outlet intended for connecting the power cord must be protected with an external overcurrent protection device either in building or in the rack with the rating not higher than 20 AMP.

Do not use an extension cord with the cable.

Always restart the system after disconnecting the system from power.

» Insert the power cable into the power connector on the rear panel of the RealPresence Collaboration Server 1800 system.

To connect the cables:

  1. Connect the management network cable to LAN 1 port.
  2. Connect the media and signaling cable to LAN 2 port.

[Diagram: Rear panel showing LAN 1 and LAN 2 ports]

To power up the system for the first time:

  1. For first entry installation, you must insert the USB key containing the modified IP addresses in the USB slot on the system's back panel. For more information see, the system's Getting Started Guide, “Procedure 1: First-time Power-up”.
  2. Turn ON the power by pressing on the ON/OFF button located on the front panel of the RealPresence Collaboration Server 1800.

[Info] You are required to register all Polycom Software Licenses that you have purchased when retrieving the Activation Key. For example, Encryption and Network Separation each have different Polycom Software Licenses.

The parameters in the lan.cfg file are uploaded from the USB key to the system's memory and applied during the power-up sequence.

System power-up sequence may take up to five minutes.

When the system's configuration is completed (including the Management and IP Network Services), and if there are no System Errors, the STATUS LED (on the system's front panel) turns green.

RealPresence Collaboration Server 1800 Front Panel

You can power on or off the system, and view the system status from its front panel.

[Diagram: Front panel of the RMX 1800 with numbered ports and LEDs: 1-LAN 1 LED, 2-LAN 2 LED, 3-STATUS LED, 4-M/S LED, 5-PWR LED, 6-ON/OFF button]

Front Panel Indicators
No.NameDescription
1LAN 1 LEDOff - No network connection
Green - Network connected
Flickering green - In use
2LAN 2 LEDOff - No network connection
Green - Network connected
Flickering green - In use
3STATUS LEDRed - System alarms
Green - Endpoints are connected to a meeting
Flickering green - No system alarms and no endpoints connected to the meeting
Flickering blue - Diagnostic tests are running
Blue - Diagnostic tests are completed. Remove the USB key (if applicable) and restart the system
4M/S LEDBlue - System upgrade completed, waiting for reboot
Flickering blue - System upgrading in progress
Green - The system works normally, either in single mode, or as the master MCU in the hot backup mode
Flickering green - The system works normally, as the slave MCU in the hot backup mode
5PWR LEDGreen - Power normal
Red - Power alarms
6ON/OFF buttonPower the RealPresence Collaboration Server 1800 System on or off.

RealPresence Collaboration Server 1800 Rear Panel

The RealPresence Collaboration Server 1800 rear panel contains built-in power and fan units, USB, LAN, and serial ports.

[Diagram: Rear panel of the RMX 1800 showing ports: 1,2-Power socket and fan; 3-Serial (RS 232); 4-USB 1; 5-USB 2; 6-LAN 1; 7-LAN 2]

Rear Panel Ports
No.PortDescription
1, 2Power socket and fanBuilt-in power socket and fan
3Serial (RS 232)Diagnostics only
4USB 1For USB key connection. For more information, see the RealPresence Collaboration Server 1500/1800/2000/4000 Getting Started Guide, “First Time Installation and Configuration”.
5USB 2For USB key connection. For more information, see the RealPresence Collaboration Server 1500/1800/2000/4000 Getting Started Guide, “First Time Installation and Configuration”.
6LAN 1For management network connection. When LAN redundancy is enabled, LAN 1 is used for both management, media and signaling network connection.
7LAN 2For media and signaling network connection. When LAN redundancy is enabled, LAN 2 is the backup of LAN 1 port.

Power Unit and Status

From version 8.3 and onwards, RMX 1800 supports a redundant power unit. The two power units back up each other and are hot swappable.

Get a redundant power unit

[Info] Your RMX 1800 is shipped with one power unit by default. To get a redundant power unit, contact your channel sales representatives.

To insert a power unit:

  1. Slide the power unit into the chassis until it snaps into place. The system beeps because it detects a power unit inserted but without power supply connected.
  2. Connect it to a power supply using the supplied power cable. The system stops beeping.

3. Switch on the power of the desired power unit.

[Diagram: Rear panel showing power unit insertion with numbered steps 1 and 2]

To remove a power unit:

  1. Disconnect the power cable from the power unit. The system beeps because it detects a power unit inserted but without power supply connected.
  2. Pull the power unit out using its handle. The system stops beeping.

[Diagram: Rear panel showing power unit removal with numbered steps 1 and 2]

To view the power unit status:

» In the RMX Management pane, click the [Monitor] Hardware Monitor.

Power Unit Status
SlotTypeStatusTemperatureVoltage
RMXNormalNormalNormal
1DSP CardNormalNormal-
2DSP CardNormalNormal-
3DSP CardNormalNormal-
FANSNormal--
PWRNormalNormalNormal
LANSNormal--

The following table describes the power unit status.

Power Unit Status Description
StatusDescription
NormalInserted power units work normally.
AbnormalAt least one of the inserted power units work abnormally. For more information, see "To troubleshoot power unit abnormal status:" on page 1-14.

To troubleshoot power unit abnormal status:

The power unit status changes to Abnormal in one of the following cases:

  • One of the power units is not connected to the power supply. The system beeps because it detects a power unit inserted but without power supply connected. You can either connect the power unit to the power supply, or remove it from the system.
  • One of the power units is removed.
  • One of the power units fails. Remove or replace the problem power unit. Power units are hot swappable and you don't need to restart the system for it to work. You can re-plug in the power cable to dismiss the Abnormal status.

Regulatory Notices

Important Safeguards

Read and understand the following instructions before using the system:

  • Close supervision is necessary when the system is used by or near children. Do not leave unattended while in use.
  • Only use electrical extension cords with a current rating at least equal to that of the system.
  • Always disconnect the system from power before cleaning and servicing and when not in use.
  • Do not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth.
  • Do not immerse the system in any liquid or place any liquids on it.
  • Do not disassemble this system. To reduce the risk of shock and to maintain the warranty on the system, a qualified technician must perform service or repair work.
  • Connect this appliance to a grounded outlet.
  • Only connect the system to surge protected power outlets.
  • Keep ventilation openings free of any obstructions.
  • If the system or any accessories are installed in an enclosed space such as a cabinet, ensure that the air temperature in the enclosure does not exceed 40°C (104° F). You may need to provide forced cooling to keep the equipment within its operating temperature range.
  • Do not use this product near water.
  • Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lighting.
  • Disconnect BOTH power cords to electrically isolate the system, and before removing any covers.
  • Note: The appliance inlet can be used as the disconnect device.
  • No user serviceable parts are contained within the device.

[Safety] The device contains a lithium cell. Risk of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacture. Dispose of used batteries according to the manufacturer's instructions.

SAVE THESE INSTRUCTIONS.

Remarques importantes concernant la sécurité

Lisez les instructions suivantes et assurez-vous de bien les comprendre avant d'utiliser le système :

  • Supervisez attentivement toute utilisation du système par ou près d'enfants. Ne laissez pas le système fonctionner sans surveillance.
  • N'utilisez que des rallonges électriques dont le courant nominal est supérieur ou égal à celui du système.
  • Débranchez toujours le système de la prise secteur avant de le nettoyer, de le dépanner et lorsque vous ne l'utilisez pas.
  • Ne vaporisez pas de liquides directement sur le système lorsque vous le nettoyez. Appliquez toujours le liquide sur un tissu antistatique.
  • Ne plongez jamais le système dans un liquide et ne posez jamais de liquide dessus.
  • Ne démontez pas le système. Pour réduire tout risque d'électrocution et pour maintenir la garantie du système, les travaux de maintenance et de réparation doivent être effectués par un technicien qualifié.
  • Branchez le système à une prise mise à la terre.
  • Ne branchez ce système qu'à des prises protégées contre les surtensions.
  • N'obstruez pas les orifices de ventilation de l'appareil.
  • Si le système ou des accessories sont installés dans un espace fermé tel qu'une armoire, veillez à ce que la température de l'air ne dépasse pas 40°C (104° F). Pour maintenir la température dans les limites d'utilisation du système, vous pourrez être amené à prévoir un système de refroidissement forcé.
  • N'utilisez pas ce produit près de l'eau.
  • Évitez d'utiliser ce produit pendant un orage. La foudre pourrait causer des électrocutions, même si le risque est faible.
  • Avant de retirer un capot, débranchez les DEUX câbles d'alimentation pour séparer le système de l'alimentation en électricité.
  • Remarque : La prise d'entrée de l'appareil peut servir à le débrancher.
  • Le système ne contient aucune pièce réparable par l'utilisateur.

L'appareil contient une pile au lithium. Son remplacement par une pile de type incorrect peut entraîner un risque d'explosion. Ne remplacez la pile que par un modèle identique ou équivalent, conformément aux recommandations du fabricant. Mettez les piles usagées au rebut conformément aux instructions du fabricant.

CONSERVEZ CES INSTRUCTIONS.

USA and Canadian Regulatory Notices

This Class [A] digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. In accordance with part 15 of the FCC rules, the user is cautioned that any changes or modifications not expressly approved by Polycom Inc. could void the user's authority to operate the equipment.

Russia Regulatory Information

Russia Regulatory Information
СистемаНомер регистрацииДата истечения срока
RMX 1800Д-СПД-6669April 03, 2017

Customs Union (Russia, Belarus, Kazakhstan) Regulatory Information

Customs Union Regulatory Information
СистемаНомер регистрацииДата истечения срока
RMX 1800KZ.7500506.23.01.00068April 21, 2019

EU Regulatory Notices

This Polycom RMX 1800 system has been marked with the CE mark. This mark indicates compliance with EEC Directives 2006/95/EC and 2004/108/EC. A full copy of the Declaration of Conformity can be obtained from Polycom Ltd, 270 Bath Road, Slough, Berkshire, SL1 4DX, UK.

Japan

この装置は、情報処理装置等電波障害自主規制協議会(VCCI)の基準に基づくクラス A 情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがあります。この場合には使用者が適切な対策を講ずるよう要求されることがあります。

Chinese

声明 此为A级产品,在生活环境中,该产品可能会造成无线电干扰。在这种情况下,可能需要用户对其干扰采取切实可行的措施。

Korea

A급 기기(업무용 방송통신기자재)

이 기기는 업무용 (A급) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.

PDF preview unavailable. Download the PDF instead.

rmx-1800-hardware-guide Acrobat Distiller 10.0.0 (Windows)

Related Documents

Preview Polycom RealPresence Collaboration Server 1800 Quick Start Installation Guide
A quick start guide for installing and performing the initial configuration of the Polycom RealPresence Collaboration Server 1800.
Preview Polycom RealPresence Collaboration Server (RMX) 1500 Hardware Guide
Comprehensive hardware guide for the Polycom RealPresence Collaboration Server (RMX) 1500, covering specifications, system capacities, installation, component details, and regulatory information.
Preview Polycom RealPresence Collaboration Server RMX1800 Installation Quick Start Guide
This guide provides instructions for the initial installation and setup of the Polycom RealPresence Collaboration Server RMX1800, covering basic hardware connections, network configuration via USB, first-time power-up, system initialization, and conference connection methods.
Preview Polycom RealPresence Collaboration Server RMX Administrator's Guide for Maximum Security Environments
Comprehensive guide for administrators and network engineers on configuring, deploying, and managing Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000 systems, focusing on maximum security environments.
Preview Polycom RealPresence Collaboration Server RMX 1500/2000/4000 Administrator's Guide for Maximum Security Environments
Administrator's Guide for Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000, detailing configuration, deployment, and management for maximum security environments. Covers conferencing modes, profiles, network services, and advanced features.
Preview Polycom RealPresence Collaboration Server RMX Deployment Guide for Maximum Security Environments
This document provides detailed guidance for deploying Polycom RealPresence Collaboration Server (RMX) 1500, 2000, and 4000 models in maximum security environments. It covers hardware installation, network configuration, system setup, and basic operation, aligning with U.S. Department of Defense (DoD) security requirements and UC APL standards.
Preview Polycom IT Hardware EPL 3760: Product Catalog and Pricing
Explore the Polycom IT Hardware Estimated Price List (EPL) 3760, featuring a comprehensive catalog of video conferencing, collaboration solutions, software licenses, and associated services with pricing details.
Preview Polycom RealPresence Platform Solution Design Report
A detailed solution design report outlining the implementation of Polycom's RealPresence Platform and RealConnect to integrate video conferencing with Microsoft Lync for enhanced collaboration, addressing current challenges and proposing a streamlined user experience.