APERA INSTRUMENTS

901 Intelligent Magnetic Stirrer

Instruction Manual

1. Brief Introduction

Thank you for purchasing Apera Instruments 901 intelligent magnetic stirrer. This product has the following features:

2. Specifications

3. How to Use

  1. Take out the white rubber cap and insert DC6V power adaptor, or screw out the bottom cap and insert 4 AA batteries.
  2. Put the beaker or test bottle that contains solution on the working area, and put stir bar of proper size into it. The container should be placed on the center of the working area according to the circle line in order to let the stir bar spin smoothly.
  3. When the green light flickers after pressing ON/OFF button, the stirrer is powered on, but the rotation speed is zero: press ▲ or ▼ button to adjust rotation speed, press RPM button (the green light flickers), then the original speed (factory default speed) will appear and user can also customize this speed: press RPM button again (the green light disappeared), the speed which has already been adjusted will be restored. Therefore, two kinds of speed can be adopted alternately by pressing RPM button.
  4. Setting the stored rotation speed: press ON/OFF button to power on: press ▲ or ▼ button to adjust to desired speed, long press RPM button for 3 seconds until the green light flickers and then release the button, the speed is then stored. Press ON/OFF button to power off. Next time after powered on, just press RPM button again, and the previously stored rotation speed will be appearing.
  5. The highest rotation speed for this stirrer is 100 grade, meaning the ▲ button can be pressed for 100 times to reach the highest speed. But if the ▲ or ▼ button is long pressed or held, the rotation speed can be changed much more quickly.

4. Notes

  1. If powered by batteries, please carefully cover on the white rubber cap of the DV power outlet.
  2. If the bottom of container is rough, the stirrer will be shaking when stirring or couldn't stir properly. So users should replace it with a qualified container.
  3. When using batteries to power on, if the power of battery is lower than 5V, the red indicator under the panel will be lighted, indicating that the stored rotation speed will become slower. So it's time for users to replace new batteries. However the speed can also be increased when pressing the ▲ button. If user doesn't really care the accuracy of the stored rotation speed, the stirrer can still be used even if the red indicator is flickering until power is completely consumed.
  4. In the situation of zero rotation speed, please don't long press the RPM button, otherwise the stored speed will be set to zero—press RPM button, if the green light doesn't flicker, it means rotation speed is zero -- under that situation, users only need to press ▲ button and reset it.
  5. This stirrer comes with B835 and B628 stir bars (one for each), which can meet most common requirements. If users need other kinds of stir bars, please buy accordingly.

5. Accessories

6. Warranty

We warrant this stirrer to be free from defects in material and workmanship and agrees to repair or replace free of charge, at option of APERA INSTRUMENTS (Europe) GmbH, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS (Europe) GmbH for a period of two years from the delivery. This warranty does not apply to defects resulting from actions such as misuse (violation of the instructions in this manual or operations in the manner not specified in this manual), improper maintenance, and unauthorized repairs. Warranty period is the time limit to provide free service for the products purchased by customers, not the service life of the product.

APERA INSTRUMENTS (Europe) GmbH

Wilhelm-Muthmann-Straße 18

42329 Wuppertal, Germany

Contact: info@aperainst.de

Website: www.aperainst.de

Tel. +49 202 51988998

Models: 901 Intelligent Magnetic Stirrer, 901, Intelligent Magnetic Stirrer, Magnetic Stirrer, Stirrer

File Info : application/pdf, 2 Pages, 127.75KB

PDF preview unavailable. Download the PDF instead.

Manual-901-EN

References

GPL Ghostscript 9.50

Related Documents

Preview Apera Instruments Model 801 Magnetic Stirrer: Instruction Manual
Instruction manual for the Apera Instruments Model 801 Magnetic Stirrer, detailing its specifications, operating instructions, and warranty information for industrial, scientific, and home use.
Preview LabSen 373 Flat pH Electrode User Manual | Apera Instruments
User manual for the Apera Instruments LabSen 373 Flat pH Electrode, detailing technical specifications, usage, maintenance, and warranty information for accurate surface pH measurements.
Preview Apera LabSen 241-180 pH Electrode User Manual
User manual for the Apera Instruments LabSen 241-180 Micro pH Electrode, detailing its features, technical specifications, usage, maintenance, and limited warranty.
Preview APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter Instruction Manual
Comprehensive instruction manual for the APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter, covering specifications, operation, calibration, maintenance, and troubleshooting for laboratory use.
Preview Apera LabSen 241-3 Micro pH Electrode User Manual
User manual for the Apera LabSen 241-3 Micro pH Electrode, detailing technical specifications, usage, maintenance, and warranty information for laboratory applications.
Preview PH60Z-HT Smart pH Meter User Manual - Apera Instruments
User manual for the Apera Instruments PH60Z-HT Smart pH Meter, detailing its features, operation, calibration, maintenance, and troubleshooting for high temperature and caustic solutions.
Preview Apera EC20 Pocket Conductivity Tester: Instruction Manual & Guide
Comprehensive instruction manual for the Apera EC20 Pocket Conductivity Tester. Learn about setup, calibration, conductivity measurement, technical specifications, and warranty information.
Preview LabSen 371 Plastic Flat pH Electrode User Manual | APERA INSTRUMENTS
User manual for the APERA INSTRUMENTS LabSen 371 Plastic Flat pH Electrode, detailing technical specifications, usage, maintenance, and warranty information for surface pH measurements.