Apera Instruments Manuals & User Guides
Apera Instruments manufactures precision electrochemical sensors and meters for measuring pH, conductivity, ORP, dissolved oxygen, and turbidity in laboratory and industrial environments.
About Apera Instruments manuals on Manuals.plus
Apera Instruments is a leading manufacturer of electrochemical sensors and scientific instruments, established in 1991. Dedicated to providing reliable and affordable testing solutions, the company produces a wide range of meters for measuring pH, oxidation-reduction potential (ORP), conductivity, TDS, salinity, dissolved oxygen, and turbidity. With over 30 years of industry experience, Apera Instruments operates R&D and manufacturing facilities certified to ISO 9001:2015 standards, ensuring strict quality control and continuous innovation.
The brand is well-known for its pocket-sized testers, such as the popular PH60 series, as well as portable and benchtop meters designed for agriculture, hydroponics, environmental monitoring, and food processing. Apera also integrates modern technology into its products, offering smart meters compatible with the ZenTest® mobile app for data management and analysis via Bluetooth. Headquartered in Columbus, Ohio for the US market and Wuppertal, Germany for Europe, Apera Instruments provides global support and expertise in water analysis.
Apera Instruments manuals
Latest manuals from manuals+ curated for this brand.
APERA INSTRUMENTS PH60 Premium pH Tester User Manual
APERA INSTRUMENTS PH60Z-SA Smart pH Meter User Manual
Apera Instruments PH60-HF pH Meter For Strong Acidic Solutions and HF Containing Solutions User Manual
APERA INSTRUMENTS PH60Z-HF Smart pH Meter User Manual
APERA INSTRUMENTS PH60Z-MT Smart pH Tester Kit User Manual
Apera Instruments PH60-PW pH Meter For Pure Water User Manual
APERA INSTRUMENTS PH60-MS pH Meter for Small Volume Measurement User Manual
APERA INSTRUMENTS TN420 Portable Turbidity Meter Instruction Manual
APERA INSTRUMENTS WS100 Fluoride pH Portable Meter Kit User Manual
Apera Instruments 1M LiCl in Ethanol Safety Data Sheet (SDS)
PH8500 Portable pH Meter User Manual - Apera Instruments
Apera Instruments TDS20 Value TDS Meter User Manual
Apera LabSen 845 pH/Temp. Electrode User Manual
Apera Instruments Water Hardness Calibration Solution B1, B2, B3 Safety Data Sheet (SDS)
Apera PH20 Value pH Tester Kit User Manual - Guide and Specifications
EC850 Portable Conductivity Meter User Manual
Apera TN500 Portable Turbidity Meter: Instruction Manual and Specifications
Apera PH20 Value pH Tester Kit User Manual
Apera Instruments PH60 Premium pH Tester User Manual
Apera PH60 pH Tester User Manual - Guide and Specifications
APERA Instruments pH 4.00 Buffer Solution Safety Data Sheet
Apera Instruments manuals from online retailers
Apera Instruments AI311 PH60 Waterproof pH Pocket Tester Kit User Manual
Apera Instruments PC60-Z Bluetooth Multi-Parameter Smart Tester Instruction Manual
Apera Instruments MP511 Benchtop pH Meter User Manual
Apera Instruments 201DJ-C AI3115 Double-Junction pH Electrode User Manual
Apera Instruments GroStar Series GS3 EC/ppm Pen Tester Kit (AI103G) User Manual
Apera Instruments GroStar Series GS2-E Replacement Soil Spear pH Probe (AI802G) User Manual
Apera Instruments AI316 PC60 5-in-1 pH/EC/TDS/Salinity/Temperature Meter User Manual
Apera Instruments LabSen 823 pH/Temperature Electrode User Manual
Apera Instruments SX811-SS Portable pH Meter User Manual
Apera Instruments AI521 PH800 Laboratory Benchtop pH Meter Kit Instruction Manual
Apera Instruments PH850-MS Portable pH Meter Kit User Manual
Apera Instruments PH820 Benchtop pH Meter Kit User Manual
Apera Instruments video guides
Watch setup, installation, and troubleshooting videos for this brand.
Apera Instruments support FAQ
Common questions about manuals, registration, and support for this brand.
-
How often should I calibrate my Apera pH meter?
For high-accuracy measurements (≤ ±0.02 pH), calibrate the electrode before every test session. For general use (≥ ±0.1 pH), calibration every 1-2 weeks is usually sufficient. Calibration is also required if the electrode has not been used for a long time or after measuring strong acids/bases.
-
How should I store the pH electrode when not in use?
Add a few drops of 3M KCL soaking solution (SKU: AI1107) to the protective cap and close it tight. Never store the electrode in distilled, RO, or deionized water, as this will damage the sensor sensitivity.
-
What do I do if I see white crystals around the probe cap?
White crystals are normal and indicate the presence of the 3M KCL storage solution, which crystallizes over time. These are not poisonous; simply rinse them off with water before using the tester.
-
Why is my pH reading unstable or slow to stabilize?
Unstable readings often occur when measuring pure water (distilled/RO) due to low conductivity. Adding a specialized ionic strength adjuster or using a specialized electrode (like LabSen 803) helps. Also, ensure the glass bulb is clean and hydrated in 3M KCL solution.
-
How do I clean the electrode sensor?
For general contaminants, rinse with distilled water. for oil/fat deposits, use warm water with dish soap (soak for 5-10 mins). For protein buildup, use the Apera Electrode Cleaning Solution (AI1166). Always rehydrate in KCL solution for 12 hours after rigorous cleaning.