Paradox SR130 Outdoor Wireless Siren
Product Manual and Specifications (Version 1.0, Printed in Canada 09/2014)
Programming
To Program Using a Keypad
MG6250 | MG/SP | Feature | Details |
---|---|---|---|
[0801] | [683] | Learn Siren #1 | Press and hold "Reset/Training" switch for 3 seconds after entering the section to learn the siren. WARNING: When you press the "Reset/Training" switch, the SR130 will squawk and the strobe light will flash five times to confirm registration to the panel. |
[0802] | [684] | Learn Siren #2 | |
[0803] | [685] | Learn Siren #3 | |
[0804] | [686] | Learn Siren #4 | |
[0801] | [687] | Display Signal Strength Siren #1 | Press and hold "Reset/Training" switch for 3 seconds after entering the section to display, on a K32LCD V1.3 or higher, the signal strength the panel is receiving from the siren. |
[0802] | [688] | Display Signal Strength Siren #2 | |
[0803] | [689] | Display Signal Strength Siren #3 | |
[0804] | [690] | Display Signal Strength Siren #4 | |
[0811] | [691] | Label Siren #1 | These labels are used when reporting events via e-mail through the IP100/IP150 (MG/SP only) or SMS personal reporting (MG6250 only) and for troubleshooting purposes. Maximum 16 characters. |
[0812] | [692] | Label Siren #2 | |
[0813] | [693] | Label Siren #3 | |
[0814] | [694] | Label Siren #4 | |
[0800] | [695] | Temporary Tamper Switch Deactivation for Maintenance | Press the [enter] key after entering the section to deactivate tamper alarm until the cover is reinstalled or after 30 minutes. |
[0820] | [587] | Panel Supervision of Siren | OFF = disabled ON = enabled (default) |
Option [1] | Option [3] | Siren #1 (OFF/ ON) | The control panel supervises the presence of the SR130. If lost, the control panel will follow global supervision loss option set in the panel. |
Option [2] | Option [4] | Siren #2 (OFF/ ON) | |
Option [3] | Option [5] | Siren #3 (OFF/ ON) | |
Option [4] | Option [6] | Siren #4 (OFF/ ON) |
To Program Using BabyWare
- Open BabyWare and connect to your system.
- Go to BabyWare => Add Item => Wireless Sirens.
- Fill in the label, location, and serial number of the SR130.
- Click Save.
Certifications
CE, EN50131-4 Grade 2, En50130-5 Class IV, C-Tick
Description
The SR130 is a stand-alone, fully supervised outdoor wireless siren with built-in strobe light and wireless transceiver. With normal use, the SR130 will function up to three years without the need to replace the batteries. The SR130 uses 2-way wireless communication, which provides continuous supervision between the panel and siren with fast response to alarm signals within 4 seconds. The SR130 operates using three size "C" alkaline batteries.
Overview
Figure 1: Input/Output and Connector Details
- 1. Siren (100dB or more)
- 2. Wall tamper switch and cover tamper switch
- 3. Reset/Training switch
- 4. Tamper Switch connector
- 5. Battery pack (3 size "C" alkaline batteries)
- 6. Strobe lights
- 7. In-Field connector
- 8. Signal Strength and transmission LED
- 9. Antenna
- 10. Status LED
LED Feedback
- Signal strength/RF transmission LED
- Red blinking - sending data
- Green blinking - receiving data
- Amber flash 4x - strong signal
- Amber flash 3x - good signal
- Amber flash 2x - weak signal
- Amber flash 1x - very weak signal (relocate)
- No flash - no signal
- Status LED
- Red steady on - powered/normal operation
- Red slow blink - low battery
Installation
- Write down the serial number (on the back of the unit) and location of the SR130 for later reference, to insert into Babyware.
- Unlock the top cover by turning the captive screw.
- Remove the top cover from the siren.
- Remove the PCB cover.
- Screw the SR130 siren into the wall.
- Make sure the Anti-Tamper switch is screwed into the wall.
Figure 2: Cover Removal
Siren with Batteries
If your siren already has batteries installed you need to:
- A Remove the plastic tab between the top battery terminals and the battery compartment.
- B Leave the covers off until you train the siren.
Siren without Batteries
If your siren does not come with the batteries then:
- A Insert the batteries. Make sure to place with the proper polarity.
- B Leave the covers off until you train the siren.
- Reinstall the PCB cover.
- Reinstall the siren cover and lock.
Upgrading Firmware
The SR130 firmware can be upgraded through In-Field (V3.0 or higher) using the 307USB Direct Connect Interface.
Note: The SR130 needs the batteries installed to upgrade the firmware.
Note: Ensure that the SR130 Wireless Siren is awake before beginning the firmware upgrade. To wake up the siren, press the training/reset switch. The siren will provide you with a 60 second delay in order to begin the update.
- Remove the front cover (see Figure 2).
- Connect the 307USB to the In-Field connector (connector #8 in Figure 1).
- Refer to the firmware upgrade instructions found at: www.paradox.com => Software => In-Field Firmware Upgrade Instructions.
Tamper Supervision
If a tamper is detected, the SR130 sounds an alarm and the strobe light flashes for 4 minutes. The control panel follows the global supervision options set in the panel.
Specifications
Power | 4.5VDC (3 size "C" alkaline batteries) |
---|---|
Battery life | Up to 3 years based on normal use (e.g., 2 alarms per year with strobe for 2.5 hours and 8 squawks per day at an average of 25°C (77°F) with default alarm time set to 4 minutes. If the alarm is set for more than 4 minutes, the battery life may be reduced). |
Battery Low Voltage signal | Will be sent at 4.1 VDC (This product requires 3 x 1.5V batteries total nominal voltage 4.5VDC) |
RF frequency | 433MHz or 868MHz |
Siren | 100dB or more (1 meter) |
Dimensions | 13.43cm X 21.17cm X 5.11cm (5.29in X 8.34in X 2.01in) |
Weight | 567g (20 oz.) with batteries, 365g (12.87oz.) without |
Humidity Range | 5% to 90% |
Operating Temperature | -25°C to 55°C (-13°F to 131°F) |
RF range | Up to 70m (230 ft) |
Compatibility
- MG/SP series v4.0 or higher (except SP4000)
- MG6250 v3.0 and higher
- RTX3 v1.5 or higher
- BabyWare v2.8 or higher
- K32+ v1.0 or higher
- K32LCD v1.3 or higher
- K32LCD+ v1.0 or higher
- K32LX v1.0 or higher
- In-Field Upgrade Software v3.8 or higher
For latest updates visit paradox.com
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. The terms and conditions are subject to change without notice, from time to time, at Paradox's sole discretion. Paradox invites users to visit their website on a regular basis for the latest Limited Warranty Statement. Use of the Paradox product signifies acceptance of all warranty terms and conditions. Ensure that use of the Paradox product is in compliance with local, national, and international laws.
© 2014 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. US, Canadian and international patents may apply. BabyWare and Paradox are trademarks or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or other countries.