Important Safety Instructions
- There are no user maintainable parts; do not attempt to disassemble or repair.
- Ensure the flush plate is situated in the correct position before installation and is not exposed to excessive heat or moisture.
- The device should not be exposed to excessive knocks or bumps.
- If the accessories are damaged, they must not be used, and replacements should be ordered from the manufacturer or retailer.
Product Overview
The sensor flush plate features a modern design with two circular activation zones: a larger one for a full flush and a smaller one for a reduced flush. The unit is powered by AA batteries and includes a low battery warning indicator.
Dimensions:
- Overall Width: 210 mm
- Overall Height: 142 mm
- Depth of unit: 103.1 mm
- Mounting hole diameter for larger flush: 60 mm
- Mounting hole diameter for smaller flush: 40 mm
- Distance from wall surface to mounting bracket: 35 mm
- Distance from wall surface to front of flush plate: 12 mm
- Distance from front of flush plate to internal mechanism: 86.5 mm
- Overall depth of mechanism: 113.1 mm
Installation
Follow these steps for installation:
-
Step 1: Positioning
Choose the ideal location for your sensor flush plate. Use the control panel base to mark where you wish to install the flush plate.
-
Step 2: Cavity Creation
Measure the depth of the flush plate and create a cavity in the wall equal to this depth. Pull the pipes for installation through the cavity and thread them through the back of the base. Insert the base into the wall and screw the fixing arms (supplied) into position. The rods may need cutting down depending on the thickness of the finished wall/surface.
-
Step 3: Glass Panel Removal
Remove the glass panel completely. Push the glass front down from the top and tilt the top towards you. Un-clip the glass by expanding the clip links and keep aside until installation is completed.
-
Step 4: Battery Installation
Remove the battery compartment by simply sliding it out of the unit. Insert 4 x AA batteries (not included) into the battery compartment and keep safe for further installation.
-
Step 5: Hose Connection
Connect the air hoses from the cistern to the flush plate as shown. Attach the blue hose to the semi-circle symbol and the transparent hose to the full circle symbol.
-
Step 6: Mounting and Finalization
Ensure the cistern is fully commissioned before mounting the bracket in place. Locate the mounting bracket onto the fixing arms and secure the top left and bottom right corners with the screws provided and tighten with a screwdriver. Be careful not to overtighten. Re-connect the clip links and cable ribbon to the glass cover and insert the battery holder. Reinstall the glass plate. Once correctly installed, the flush plate will illuminate for a couple of seconds.
Operation
When the unit is first powered on, it will emit a long beep, and the indicator lights for full-flush and half-flush will illuminate for a few seconds before flashing 3 times. The product will then be ready to use.
- Reduced Flush: Hover your hand over the smaller right-hand circle to activate the flush. The LED light will illuminate.
- Full Flush: Hover your hand over the larger left-hand circle to activate the flush. The LED light will illuminate.
If the flush plate is touched for more than 5 seconds, it will not flush.
Low Battery
When the battery power is low, the product can still work normally. The LED light will flash 10 times, and an alarm will sound for 10 seconds to remind the user that the batteries are low. When there is no power, the LED light will slowly flash with a frequency of 2 times per second, and the bell will sound. If batteries are exhausted completely, the glass panel can be removed to reveal the manual flush button. The manual override is not intended as a long-term solution.
Manual Override
To use the manual push button, unplug the cable ribbon and take the front glass off the chain links. Keep safe to prevent damage.
Specifications
Feature | Specification |
---|---|
Batteries | 4 x AA (not included) |
Ingress protection | IPX4 |
Sensor distance | 0-60mm (from glass panel) |
Sensing time | 0.2-5 seconds |
Weight | 0.7 kg |
Support and Recycling
Recycling facilities are available for all customers where old electrical products can be deposited. Customers can take any old electrical equipment to participating sites run by their local councils. Please be considerate when depositing equipment as it will be further handled during the recycling process. Please contact your local council for details of your local household waste recycling centers.
At the time of printing, the product contains no substances listed within Annex XIV of the Reach Regulations (EC) 1907/2006. In accordance with Article 59 of the same regulation, the following substances are contained within the product at permitted levels: Lead & Cadmium. Better Bathrooms monitors these regulations to ensure continued compliance. Further information can be provided upon request.
For more information:
- Visit: betterbathrooms.com
- Email: customerservices@buyitdirect.co.uk
- Call: 0339 390 3062
- Write to: Trident Business Park, Leeds Road, HD2 1UA
Part of the BuyitDirect Group.