Safety Warnings

WARNING! ELECTRICAL SHOCK AND FIRE HAZARD!

The outlet is not to be connected to power prior to installation. Failure to comply with this instruction could result in an electrical failure, fire, and electrocution.

IMPORTANT: Installation of this power outlet box and related wiring must be done by a qualified electrician in compliance with all applicable electrical codes. When being used to power a structure, this outlet must be used in conjunction with a transfer switch. Not for indoor use. When using an engine-driven generator, locate away from doors and windows to avoid the build-up of carbon monoxide from the engine exhaust in enclosed areas.

Installing the Power Outlet Box

Mount the power outlet box on the outside of the building in a convenient location, using the three holes provided in the back of the cabinet. Using copper wire only and approved wiring methods, run the wiring through one of the knockouts in the cabinet to a junction box located near the transfer switch. If using conduit, pull at least four colors.

Wire Gauge: 4AWG~8AWG. Strip the wire insulation 3/5" (15mm) (do not tin conductors) and connect the wires into the power outlet box as follows. Making sure there is no wire insulation in any terminal and the outlet terminal screws are tightened to 35 inch-pounds torque using an electric flat screwdriver.

FIG1: Wire Stripping Guide

Illustration showing wire stripping to 3/5" (15mm).

Cable Color Scheme:

  • Black/Red: Load (250 Volt), terminals marked "Black" and "Red".
  • White: Neutral Conductor, connected to "White" marking terminal.
  • Green: Green power inlet wire to green ground screw terminal on inside of cabinet. If required, green wire to green ground screw terminal on inside of cabinet.
FIG2: Wiring Diagram

Diagram showing the NEMA #14-50R Receptacle connections:

  • GROUND: Green screw terminal.
  • HOT-A: Black wire.
  • HOT-B: Red wire.
  • NEUTRAL: White wire.

Enter Installation Considerations

Choose one threading hole that suits you the best (A, B, C, or D).

Hole Sizes: 1", 3/4", 1/2"

Support and Warranty

For technical support and E-Warranty Certificate, visit: www.vevor.com/support

Made In China

VEVOR is committed to providing competitive prices. Expressions like "Save Half" or "Half Price" represent an estimate of savings compared to major top brands and do not necessarily cover all product categories. Please verify savings when placing an order.

Need Help? Contact Us!

Have product questions? Need technical support? Please feel free to contact us:

Email: CustomerService@vevor.com

Models: RV-50A Power Outlet Box, RV-50A, Power Outlet Box, Outlet Box, Box

File Info : application/pdf, 2 Pages, 834.45KB

PDF preview unavailable. Download the PDF instead.

电源输入盒RV-50A说明书-0423 1687848466896

References

Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview VEVOR RV Power Outlet Box Installation Instructions & Wiring Guide
Comprehensive installation and wiring guide for VEVOR RV Power Outlet Boxes (RV-30A/50A). Covers safety, mounting, wiring connections, and cable color schemes for NEMA 14-50R, TT-30R, and LD-3008B types.
Preview VEVOR RV-30A Power Outlet Box Installation Instructions
Comprehensive installation guide for the VEVOR RV-30A Power Outlet Box. Covers safety warnings, wiring diagrams, and mounting procedures for RV and camper applications. Features AC 30A, 125/250V, NEMA TT-30R specifications.
Preview VEVOR TR9602-1L Duplex Receptacle Wall Plates - Installation Guide & Technical Support
Official installation instructions and technical support information for the VEVOR TR9602-1L Duplex Receptacle Wall Plates. Learn how to safely install your wall plates with VEVOR's guidance.
Preview VEVOR LSSP-30E RV Surge Protective Device - User Manual & Specifications
Learn how to install and use the VEVOR LSSP-30E RV Surge Protective Device. This manual provides specifications, features, installation steps, and important safety cautions for protecting your RV from power surges.
Preview VEVOR RV Scissor Jacks ST-120L, ST-120LA, ST-120CA - Installation, Operation, and Specifications
Comprehensive guide for VEVOR RV Scissor Jacks (Models ST-120L, ST-120LA, ST-120CA) covering important safeguards, assembly precautions, installation methods (bolt-on and weld-on), operation, maintenance, and specifications. Includes package contents.
Preview VEVOR RV Macerator Pump Operating Instructions
Comprehensive operating instructions for the VEVOR RV Macerator Pump, Model NMMP12-G120-12-1. Includes features, specifications, product list, wiring diagram, detailed composition, operating instructions, electrical instructions, and troubleshooting.
Preview VEVOR LTU12 RV Surge Protective Device - User Manual & Specifications
User manual and specifications for the VEVOR LTU12 RV Surge Protective Device. Covers installation, features, wiring conditions, LED indicators, and safety cautions for this 30 Amp, 2700 Joule surge protector.
Preview VEVOR RV Scissor Jacks ST-120L, ST-120LA, ST-120CA Installation and Operation Manual
Comprehensive manual for VEVOR RV Scissor Jacks (Models ST-120L, ST-120LA, ST-120CA) covering important safeguards, assembly precautions, specifications, package contents, installation methods (bolt-on and weld-on), operation, and maintenance.