Indoor Unit (IDU) Disassembly

Before disassembly

The unit is ready for disassembly. Refer to the following steps.

1. Disassemble the front panel, display board, and Wi-Fi module

A. Open the front panel.

B. Remove one screw, then take the display box out from the panel.

C. Release the panel axis, indicated by [red arrows], out from the middle frame and take the panel out.

2. Remove the louver and take the Wi-Fi module out from the middle frame

A. Remove the air guide by sliding the air guide pin to the right. The pin stays on the air guide after removing it.

B. Slide the Wi-Fi module to the left to remove it.

C. Remove the Wi-Fi retaining cover from the retaining clips and take out the USB cable.

3. Remove the louver

Unfix one screw on the cover of the electric box, and remove the cover.

4. Remove the front cover plate

A. Press the [red arrow] to loosen the 6 fixed clips between the front cover and center frame.

B. Rotate the front cover plate outward to disengage the fixing pins of the front cover plate and center frame. Then, remove the front cover plate.

5. Remove the sweep blade assembly

A. Remove the sweep blade assembly by loosening the 5 clips from the base upwards.

6. Remove the filter

A. Pinch the top of the strainer at the grommet position and slightly press upward to remove the strainer.

7. Disassemble the middle frame

A. Remove the 2 fixing screws between the center frame and base.

B. Loosen the 4 fixing clips between the upper part of the center frame and base.

C. According to the position indicated by the arrow of the center frame, press downward to loosen the 3 fixed clips between the center frame and the upper edge of the air vent on the base.

D. Follow the arrow in the center frame to indicate the position, press outward to loosen the 3 fixed clips between the center frame and the lower edge of the air vent on the base.

E. Remove the center frame upwards.

8. Disassemble the electric control box

A. Remove the electric control box and base fixing screws.

B. Remove the control box.

9. Remove the wall panels and pipe pressure plates

A. Loosen the fixing screws of the wall plate and base.

B. According to the direction of the arrow, press the fixing clips on the base wall plate. Loosen the wall plate and base fixing clips, then remove the wall plate.

C. Hold the pipe pressure plate gripper position upward, then loosen the pipe pressure plate and the base of the fixed clips. Remove the pipe pressure plate.

10. Disassemble the evaporator

A. Remove the evaporator and base fixing screws.

B. Loosen the left side of the evaporator and the base fixing buckle, then lift the left side of the evaporator upward.

C. After the left side of the evaporator is lifted, the right side of the evaporator will loosen. The evaporator can be taken out.

11. Remove the motor cover

A. Remove the motor cover and the 2 fixing screws on the base to take out the motor cover upwards.

12. Remove the cross-flow fan and motor

A. Remove the cross-flow fan and cross-flow fan motor upwards.

13. Remove the cross-flow fan motor

A. Remove the cross-flow fan motor by taking the cross-flow fan and cross-flow fan motor mounting screws out.

Outdoor Unit (ODU) Disassembly

Outdoor Unit Model Numbers:

Before disassembly

The outdoor unit is ready for disassembly. Refer to the following steps.

1: Remove the PCB cover, valve cover, and top cover

A. 1). Unfix 1 screw on the PCB cover, then you can remove the cover from the unit.

A. 2). Unfix 1 screw on the valve cover, and then you can take it out.

B. Unfix the screws on the top/left/right plates, and then you can take the top cover out.

2: Disassemble the fan guard and front panel

A. Remove the screws assembling the grille to the front panel, then remove the grille.

B. 1). Unfix the screws on the front panel of the fan guard.

B. 2). Separate the ODU middle plate and base plate. Lift the front panel so you can take it out from the unit.

3: Disassemble the left and right plate

A. Unfix screws on the right plate, electric box assembly, valve plate, and base plate. You can then take the right plate out.

B. Unfix the screws on the left plate, base plate, and condenser plate. You can then take the left plate out.

4: Disassemble the axis fan blade

A. Unscrew the fan blade nut. Remove the blade.

5: Disassemble the electric box

A. Unfix the screws on the electric box and motor supporter, etc. Loosen the wiring clamp, then you can take the control box out.

6: Remove the noise cotton

A. Take the cotton out, as shown in the picture.

7: Disassemble the separate plate

A. Unfix the screw on the separate plate and unit, then take it out.

8: Disassemble the 2-way and 3-way valve

A. Unfix the screws on the valve plate and base. You can take the 2-way and 3-way valve out by welding.

Note: 1). Welding can only occur while there is no gas in the unit. 2). Pay attention to the fire to prevent any injury.

9: Disassemble the 4-way valve assembly

A. Remove the 4-way valve from the system by welding. Ensure there is no damage to the compressor, nameplate, etc.

10: Disassemble the compressor

A. Unscrew the nuts and remove the compressor.

11: Remove the fan motor and fan supporter

A. Unfix the screws on the fan motor and supporter, then remove the supporter of the base plate.

Note: Pay attention to the motor wiring. It can't be taken out by force.

Additional Information

Refrigerant Leakage Detector Installation

Diagrams show the indoor unit assembly for refrigerant leakage detector installation.

Power Cord Mounting Plate Installation

Diagrams show the indoor unit assembly for power cord mounting plate installation.

Company Information

The design and specifications of this product are subject to change without prior notice as development continues. Consult with the sales agency or manufacturer for details. Refer to the equipment nameplate for all other applicable specifications.

PIONEER

is a registered trademark of Parker Davis HVAC International, LLC.

Parker Davis HVAC International

7290 NW 77 Court, Miami, FL 33166 - USA

Tel: (305) 513-4488

Fax: (305) 513-4499

E-mail: info@pdhvac.com

Website: www.pdhvac.com

Pioneer product line, parts, and supplies are available online for convenient ordering at:

www.highseer.com

www.pioneerminisplit.com

Support Information

Scan the below code to visit our support page where you can find more installation materials.

Copyright © Parker Davis HVAC International, LLC. All rights reserved.

Models: WYT009GLSI25RH, WYT018GLSI25RH, WYT012GLSI25RH, WYT024GLSI25RH, WYT009GLSI25RH Series Inverter Air Conditioner, WYT009GLSI25RH Series, Inverter Air Conditioner, Air Conditioner, Conditioner

PDF preview unavailable. Download the PDF instead.

WYT25-DISM-2501 macOS 版本13.5(版号22G74) Quartz PDFContext

Related Documents

Preview Pioneer WYT-25 Inverter Series Air Conditioner Parts Diagrams
Comprehensive parts diagrams and lists for Pioneer WYT-25 Inverter Series ductless mini-split air conditioners and heat pumps, including indoor and outdoor unit components for models WYT009, WYT012, WYT018, and WYT024.
Preview Pioneer Inverter Air Conditioner Service Manual - WYT Series
Service manual for Pioneer Inverter Air Conditioners (WYT009GLSI25RH, WYT012GLSI25RH, WYT018GLSI25RH, WYT024GLSI25RH). Covers technical specifications, installation, maintenance, and troubleshooting.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual
Detailed disassembly instructions for Pioneer Inverter Air Conditioner Indoor (Cassette) and Outdoor (ODU) units, covering models CYT, CT, and YN series.
Preview Pioneer Quantum Hyperformance 24,000 BTU 23 SEER2 Ductless Mini-Split Heat Pump Submittal Sheet
Submittal sheet detailing the Pioneer Quantum Hyperformance 24,000 BTU ductless mini-split inverter heat pump system. Features include 23 SEER2 rating, efficient cooling and heating performance, detailed electrical and unit specifications, dimensional data, warranty information, and available accessories.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual
Comprehensive disassembly guide for Pioneer Inverter Air Conditioner Indoor (IDU) and Outdoor (ODU) units, covering models UYT018GLSI24RL, UYT024GLSI24RL, UT018GLSILCFHG, UT024GLSILSFHG, YN018GLSI24RPG, and YN024GLSI24RPG. Provides step-by-step instructions with textual descriptions of visual aids for safe and effective disassembly.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Units Disassembly Manual
A comprehensive disassembly manual for Pioneer Inverter Air Conditioner Indoor/Outdoor Units, covering models WYT009ALSI24RL, WYT009GLSI24RL, WYT012ALSI24RL, WYT012GLSI24RL, WYT018GLSI24RL, and WYT024GLSI24RL. This guide provides step-by-step instructions for disassembling both the indoor and outdoor units.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual
Detailed disassembly guide for Pioneer Inverter Air Conditioner Indoor and Outdoor Units, covering models RYT and RT series. Includes step-by-step instructions for internal components.
Preview Parker Davis Pioneer YN030GLSI24M3G Triple Circuit Ducted Inverter Heat Pump Submittal Sheet
Technical submittal sheet for the Parker Davis Pioneer YN030GLSI24M3G multi-zone ducted inverter heat pump system. Details cooling/heating performance, electrical specs, piping, dimensions for condenser and indoor units (RT009, RT012, RT018), features, and warranty.