Statement
The product has well capability and intact packing when leaving the factory. All users should comply with warning items and the manual. Any misuse causing damages is not included in our guarantee, and the manufacturer cannot be held responsible for any malfunction or problem arising from ignoring the manual.
1. Safety Instructions
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
- Unpack and check carefully for any transportation damage before using the unit.
- Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the unit.
- It's important to ground the yellow/green conductor to earth in order to avoid electric shock.
- The unit is for indoor use only. Use only in a dry location.
- The unit must be installed in a location with adequate ventilation, at least 50 cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
- Disconnect main power before replacement or servicing.
- Make sure there are no flammable materials close to the unit while operating, as it is a fire hazard.
- Use a safety cable when fixing this unit. Do not handle the unit by taking its head only, but always by taking its base.
- Maximum ambient temperature is Ta: 40°C. Do not operate it where the temperature is higher than this. Unit surface temperature may reach up to 85°C. Do not touch the housing bare-handed during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or servicing.
- In the event of a serious operating problem, stop using the unit immediately.
- Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
- Do not touch any wire during operation, as high voltage might be causing electric shock.
Warning:
- To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
- Do not open the unit within five minutes after switching off.
- The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
Caution:
There are no user-serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit's weight. Also, always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be fixed by professionals. It must be fixed at a place where it is out of the reach of people.
2. Technical Specifications
Light Sources
- 19*40W 4IN1 RGBW LED
- Beam Angle: 3.5° - 45°
- Power Consumption: 640w
- Power Voltage: AC 100-240V, 50/60Hz
- Dimension: 376*280*420.5mm
- Net Weight: 14.5 Kgs
- Carton package 1in1 size: 53.5*39*49.5cm (Gross Weight: 18Kgs)
- Flight Case 1in2 size: 97*46*64cm (Gross Weight: 62 Kgs)
Control
- DMX Channel: 21/23/35/78/92/97/99 Channels
- Control Modes: DMX512/Master-Slave/Auto Run/Music
Pan/Tilt
- Pan: 540°/ 360°, Tilt: 270°
- Pan/Tilt Resolution: 8/16 bit
Construction
- Display: 180° reversible 1.8 inch TFT colorful Display
- Data In/Out socket: 3-pin & 5-pin XLR sockets
- Power Socket: Power Con in/out
- Protection Rating: IP20
Features
- LED single control, can display arrows, numbers, letters and patterns.
- High-efficiency optical system, wonderful flower effect plus zoom.
- Fan work speed auto adjustable with head temperature.
- LED temperature protection & Fan run speed automatic based on the head temperature.
3. Lux Data
This section presents photometric data. A diagram illustrates the light beam spread at 3.5° and 45° angles, showing spot diameter at various distances (1m, 3m, 5m, 8m). Tables provide lux values for Red, Green, Blue, and 4in1 LEDs at these distances for both beam angles.
Beam Angle = 3.5° | Distance (m) | 1 | 3 | 5 | 8 |
---|---|---|---|---|---|
R lux | 25900 | 13500 | 6350 | 2530 | |
G lux | 57300 | 28000 | 13300 | 5510 | |
B lux | 10100 | 5100 | 2690 | 1020 | |
W lux | 70000 | 35700 | 19000 | 7060 | |
4in1 lux | 142000 | 73700 | 35000 | 14400 |
Beam Angle = 45° | Distance (m) | 1 | 3 | 5 | 8 |
---|---|---|---|---|---|
R lux | 10300 | 1000 | 412 | 163 | |
G lux | 22300 | 2140 | 907 | 382 | |
B lux | 4260 | 407 | 173 | 72 | |
W lux | 27700 | 2630 | 1100 | 456 | |
4in1 lux | 57300 | 5490 | 2320 | 744 |
Distance (m) | 1 | 3 | 5 | 8 | |
---|---|---|---|---|---|
Spot diameter (m) 3.5° | 0.30 | 0.60 | 0.74 | 1.20 | |
Spot diameter (m) 45° | 0.90 | 2.70 | 3.80 |
4. How To Control The Unit
Display:
A diagram shows four circular buttons: MENU, UP, DOWN, and ENTER. The MENU button selects programming functions. UP and DOWN navigate through options. ENTER confirms selections. Instructions are provided for setting the DMX address code.
MENU: To select the programming functions
DOWN: To go backward in the selected functions
UP: To go forward in the selected functions
ENTER: To confirm the selected functions
Set DMX Address Code
- Press "Menu" to "Set DMX Address", and press "ENTER" keys to enter into it.
- Show "Set DMX Address DMX Address:001", Press the "UP and DOWN" keys to amend.
- Press "ENTER" keys to save and Exit, Press the "MENU" Keys does not save and Exit.
Menu Option | Setting | Function |
---|---|---|
Pan Degree | 1) 540° | X-axis running angle selection |
2) 360° | ||
Mic Sense | 001 - 100 | Sound sensitivity adjustment |
Language | English / Chinese | |
No Signal | 1. Black Out, 2. Hold | Set the state when the machine has no signal input |
Fan Set | 1. Auto, 2. Low, 3. High | Set fan speed |
Reset | Yes / No | |
Default | Yes / No | |
Adjust | Pass Word: **** | |
Pan | 0 - 255 | |
Tilt | 0 - 255 | |
Focus | 0 - 255 | |
Rota | 0 - 255 | |
Red | 0 - 255 | |
Green | 0 - 255 | |
Blue | 0 - 255 | |
White | 0 - 255 | |
Address | Setting from 001 - 512 | |
Forward or Reverse setting | Pan | 1. Yes / 2. No |
Tilt | 1. Yes / 2. No | |
Display | 1. Yes / 2. No | |
Information | 1. CH Value | Each channel show CH value |
2. Temp ____ °C | Show the temperature of LED | |
3. Soft V.XXX | Show the version number | |
Channel | 21 channels | |
23 channels | ||
35 channels | ||
78 channels | ||
92 channels | ||
97 channels | ||
99 channels | ||
Mode | DMX 512 | |
AUTO | ||
SOUND | ||
Manual Master Alone | Pan: 0--255 | Manual Control |
Tilt:0--255 | ||
Focus:0--255 | ||
Rota:0-255 | ||
Red: 0--255 | ||
Green: 0--255 | ||
Blue: 0--255 | ||
White: 0--255 | ||
Strobe: 0-255 |
5. DMX Channel List
The DMX Channel List details the control parameters for various configurations of the Bee Eye Zoom moving head. Each model is assigned a specific number of DMX channels, which map to functions such as color mixing (Red, Green, Blue, White), dimming, pan and tilt movement, zoom, strobe effects, patterns, and more. The following models and their respective channel counts are detailed:
- Model 1 - CH21 (21 Channels)
- Model 2 - CH23 (23 Channels)
- Model 3 - CH35 (35 Channels)
- Model 4 - CH78 (78 Channels)
- Model 5 - CH92 (92 Channels)
- Model 6 - CH97 (97 Channels)
- Model 7 - CH99 (99 Channels)
Detailed channel functions and value ranges are provided for each model in the original document.
6. Shape
Dimension drawings of the moving head fixture are provided. The front view shows a width of 376mm and a height of 420.5mm. The side view indicates a depth of 280mm and a height of 403.5mm. The base height is 115mm.
7. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
- Check the connection of power and main fuse.
- Measure the mains voltage on the main connector.
- Check the power on LED.
B. Not responding to DMX controller
- DMX LED should be on. If not, check DMX connectors, cables to see if linked properly.
- If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
- If you have intermittent DMX signal problems, check the pins on connectors or on the PCB of the unit or the previous one.
- Try to use another DMX controller.
- Check if the DMX cables run near or run alongside high voltage cables that may cause damage or interference to the DMX interface circuit.
C. One of the channels is not working well
- The stepper motor might be damaged or the cable connected to the PCB is broken.
- The motor's drive IC on the PCB might be out of condition.
8. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky, or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
- Clean with a soft cloth using normal glass cleaning fluid.
- Always dry the parts carefully.
- Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.