Instruction Manual for SEALEY models including: APMRT2, APMRT2 Modular Racking Top Unit 2 Shelves 580mm, APMRT2, Modular Racking Top Unit 2 Shelves 580mm, Racking Top Unit 2 Shelves 580mm, Top Unit 2 Shelves 580mm, 2 Shelves 580mm

Instructions for the Sealey APMRT2 Modular Racking Top Unit 2 Shelves 580mm

Sealey APMRT2 Modular Racking Top Unit 2 Shelves 580mm » Product

Instructions Instructions

Modular Racking Top Unit 2 Shelves 580mm - Vinny Byrne

Instructions690 KB PDF

Modular Racking Top 2 Shelves Unit 580mm - Anvil Tool


File Info : application/pdf, 3 Pages, 689.86KB

PDF preview unavailable. Download the PDF instead.

APMRT2-Instructions-20240624-1 DFC1642961
MODULAR RACKING TOP 2 SHELVES UNIT 580MM
MODEL NO: APMRT2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Refer to instructions

Wear eye protection

1. SAFETY



WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this product.

9

Locate product in a suitable working area.

9

Keep the work area clean, uncluttered and ensure there is adequate lighting.



WARNING! Use product on level and solid ground, preferably concrete. Avoid tarmacadam since the product may sink into the surface.

9

Keep the product clean and tidy in accordance with good workshop practice.

9

Keep children and unauthorised persons away from the working area.

8

DO NOT use the product for any purpose other than that for which it is designed.

8

DO NOT exceed maximum capacity of product.

8

DO NOT undertake work on the product without the work piece being adequately secured. Use clamps or a vice (not included) to secure the

work piece. Available from your Sealey stockist.

8

DO NOT use the product out of doors.

8

DO NOT get the product wet or use in damp or wet locations or areas where there is condensation.

8

DO NOT clean the product with any solvents which may damage the paint surface or the protective coating.

2. INTRODUCTION

The Sealey modular racking system is finished with a heavy-duty textured powder coat to prevent against rusting. Simply choose your base, middle and top units and push together using nylon connectors to create versatile storage for the workshop, garage, home
or office. All drawers have ball-bearing drawer slides for smooth operation and cupboard doors are fitted with spring loaded hinges allowing them to be fitted the side that suits your environment. Buy individually (see specific model number for full specs) or as one of our pre-created combo's.

3. SPECIFICATION

Model no: Nett Weight: Size (W x D x H): Shelves:

APMRT2 5.3kg 580 x 340 x 444mm 2

4. CONTENTS

Item 1 2 3 4 5
8 6
--

Part APMRT2-01 APMRT2-02 APMRB1-04 APMRB1-07 MSP612.S
APMRT1-11 APMRB1-09
APMRB1-10

Description Upright Top panel Top/Bottom Panel Plastic End Plug Machine Screw Pan Head Phillips M6 x 12mm Sealey Badge Self Tapping Screw ST4.8 x 30 (Not Shown) Expansion Plug M8 x 40mm (Not Shown)

5 8
1 3

2 4

© Jack Sealey Limited

Original Language Version

APMRT2 Issue 1 24/06/24

5. ASSEMBLY
5#

3# Hole

1#

3#

Step 1. Assemble the uprights, bottom panel with screws M6*12 as shown.

Step 2. Assemble the top panel with screws M6*12.

4#

Hole

Step 3. Insert the plastic end plugs into the uprights. Option 1

Step 4. To fix on the wall, mark the wall according to the hole which is at the back of top panel, after assembly.

7#
6#
Step 5. To fix the cabinet on to the wall. Mark the wall out before drilling the hole, after the wall has been marked drill a hole the size required as illustration, Insert the wall plug 8*40.

© Jack Sealey Limited

Step 6. Fix the cabinet to the wall using the self-tapping screw ST4.8*30.

Original Language Version

APMRT2 Issue 1 24/06/24

Option 2
6# Step 7. To fix the cabinet on to a wooden wall. Mark the wall out before drilling. After the wall has been marked, drill a hole the correct size as illustration.
Step 8. Fix the cabinet on the wooden wall with the self-tapping screw ST4.8*30, no wall plug is required.

Step 9. Assembly completed.

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No Liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

01284 757500

sales@sealey.co.uk

www.sealey.co.uk

© Jack Sealey Limited

Original Language Version

APMRT2 Issue 1 24/06/24



References