Comfort Aire Century CXP1560SA-1 Air Handler Heat Pump System
Submittal Data
Specifications
Indoor Unit Dimensions
Dimensions (W×D×H): 21.61 x 21.50 x 27.80 inches (549×546×706 mm)
Package Dimensions (W×D×H): 31.69 x 25.59 x 26.57 inches (805×650×675 mm)
Net/Gross Weight: 44/52 lbs (43.9/52.2 kg)
Supply Air Opening Width: Varies by model (e.g., 16-3/16 inches for MXP18/24B1A)
Return Air Opening Width: Varies by model (e.g., 14-5/16 inches for MXP18/24B1A)
Condensate Drains Height: 1-7/16 inches (38 mm)
Liquid Line Height: Varies by model (e.g., 11-3/8 inches for MXP18/24B1A)
Outdoor Unit Dimensions
Dimensions (W×D×H): 37.48 x 16.34 x 52.48 inches (952×415×1,333 mm)
Package Dimensions (W×D×H): 43.11 x 16.34 x 58.27 inches (1,095×415×1,480 mm)
Net/Gross Weight: 212.30/244.49 lbs (96.3/110.9 kg)
Efficiency
- SEER2: 15.6
- EER2: 9.8
- HSPF2-4: 9.8
- COP: Not specified
Performance of Cooling
- Rated Capacity: 52,000 Btu/hr
- Min/Max Capacity: 20,400~56,000 Btu/hr
- Moisture Removal: 8.1 L/h
- Standard Operating Range: -13~122°F (-25~50°C)
- Rated Cooling Conditions: Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB
Performance of Heating
- @ 47°F Rated: Not specified
- @ 47°F Min/Max Capacity: Not specified
- @ 17°F Rated: Not specified
- @ 5°F Rated: Capacity / COP: Not specified
- @ 5°F Max: Capacity: Not specified
- Standard Operating Range (°F/°C): Not specified
- Rated Heating Conditions: Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
- Rated Heating Conditions: Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
- Heating Conditions, Compressor Operating at Max. Frequency: Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB
Electrical
- Indoor Power Supply: 24V, 60Hz, 1Ph
- Indoor MCA: 115V/(208/230V)
- Indoor MOP: Not specified
- Outdoor Power Supply: 208/230, 60Hz, 1Ph
- Outdoor MCA: 37 A
- Outdoor MOP: 40 A
- Communication Wiring: AWG 20-2
- Compressor RLA: 27.5 A
- Outdoor Fan Motor RLA: 2.4 A
- Outdoor Fan Motor W: Not specified
- Indoor Fan Motor RLA: Not specified
- Indoor Fan Motor W: Not specified
- System Power Input @ Cooling (W): 5,306 (1,530~5,960) W
- System Power Input @ Heating (W): Not specified
- MCA: Min. circuit amps (A): Not specified
- RLA: Rated load amps (A): Not specified
- MOCP: Max. over current protection (A): Not specified
- W: Fan motor rated output (W): Not specified
Piping
- Throttle type(Indoor): EXV
- Throttle type(Outdoor): EXV
- Liquid Size: 9.52mm(3/8in)
- Gas Size: 19mm(3/4in)
- Max. Piping Length: 246 ft (75 m)
- Max. Height Difference: 98 ft (30 m)
- Max. Pre-charged Length: 24.6 ft (7.5 m)
- Refrigerant Pre-charged Amount: 169.32 oz (4.80 kg)
- Additional Charge of Refrigerant: 0.7 oz/ft (65 g/m)
- Connection Method: Flared
Outdoor Unit Installation Instructions
Clearance requirements for the outdoor unit:
- 4 inches (100mm) or more on sides.
- 14 inches (350mm) or more on the rear.
- 20 inches (500mm) or more in front and on sides if any 2 sides of left, right, and rear of the unit are clear.
- 20 inches (500mm) or more when front and sides of the unit are clear.
Features
- Multi-position installation: horizontal (left or right), vertical (up or down).
- Aluminum Coil.
- R454B refrigerant sensor.
- Easy Maintenance.
- Multiple control options available:
- Two-way communication wired controller with built-in WiFi: 120N(X6W).
- Third-Party 24V Thermostat.