Vicks Warm Mist Humidifier Use and Care Manual

Model V750 Series

Introduction

This humidifier adds water vapor to the surrounding air. For questions about operation, contact Vicks Consumer Relations at 1-800-VAPOR-1-2 (1-800-827-6712) or visit www.VicksHumidifiers.com/contact-us.

IMPORTANT! READ AND SAVE THESE INSTRUCTIONS

The Vicks Warm Mist Humidifier is designed to quietly provide visible warm moisture. Water from the tank feeds into the boiling chamber, where it is heated into steam vapor. The steam vapor then mixes with dry air in the mist chimney, releasing warm, moist air into the room.

Key Features:

Important Safety Instructions

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following:

  1. Place the appliance on a firm, flat, waterproof surface at least four feet (1.22m) from bedside and twelve inches (30cm) from the wall.
  2. KEEP OUT OF REACH OF CHILDREN AND PETS. Ensure the appliance is stable and the power cord is away from heated surfaces and out of the way to prevent tripping.
  3. Do not leave the appliance unattended in a closed room, as air could become saturated and cause personal injury or property damage.
  4. Before use, extend the cord and inspect for damage. DO NOT use if the cord is damaged.
  5. The appliance has a polarized plug (one blade wider than the other) for safety. It fits into a polarized outlet only one way. If it does not fit fully, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  6. To avoid fire or electric shock, plug directly into a 120V AC electrical outlet.
  7. Always unplug and empty the appliance when not in operation or when cleaning. Shut off and unplug the humidifier before moving. DO NOT move or tilt the humidifier while in operation. Plug and unplug with dry hands. NEVER pull by cord.
  8. DO NOT operate the appliance without water. Turn off and unplug when the tank is empty and the reset light is on.
  9. CAUTION: To avoid the risk of fire, electric shock, or personal injury, DO NOT use an extension cord or power strip.
  10. Appliance requires regular cleaning. Refer to and follow cleaning instructions.
  11. DO NOT operate outdoors; this appliance is intended for indoor use.
  12. DO NOT cover or insert objects into any openings on the unit.
  13. DO NOT attempt to repair or adjust any electrical or mechanical functions on this appliance, as doing so will void your warranty.
  14. DO NOT add any medications (e.g., Kaz Inhalant or Vicks VapoSteam) into the Chimney, Base, Reservoir, or Water Tank.
  15. DO NOT touch the steam vapor, as it can cause burns. DO NOT operate without the Medicine Cup in place on top of the Mist Chimney.
  16. When moving or lifting the Tank, use one hand on the Tank Handle and the other on the bottom of the tank.
  17. DO NOT touch skin with exposed VapoPad or place on furniture, fabric, bedding, or plastic.
  18. For Residential Use Only.

SAVE THESE INSTRUCTIONS

V750 Accessories

The following accessories work great with your humidifier and can be purchased at most major retailers or through www.VicksHumidifiers.com:

Setting Up Your Vicks Warm Mist Humidifier

Step 1: Remove from box. Remove packaging material. Set aside instruction manual. Recycle packaging materials or save for storage.

Step 2: Remove twist tie from power cord and extend power cord full length. DO NOT OPERATE WITH POWER CORD COILED OR TWIST TIE IN PLACE.

Step 3-4: Ensure Proper Assembly. Make sure Mist Chimney and Water Tray are securely in place and the blue latch is engaged.

Step 5: Select a firm, level location at least 12" (30cm) from any walls. Place the humidifier on a water-resistant surface. Steam should be directed away from any walls, bedding, or furniture.

WARNING: KEEP OUT OF REACH OF CHILDREN. This product produces HOT STEAM and should be placed in an area not accessible to children or pets, with the power cord also securely out of reach.

Filling/Refilling

NOTE: Tank should be carried using two hands. One hand on the carrying handle on the tank's top, and the other hand supporting the bottom of the tank.

Step 1: Remove Tank by grasping handle and pulling up. Remove Tank Cap located on the bottom of the Tank by turning counter-clockwise.

Step 2: Fill Tank with cool water. DO NOT fill with warm or hot water.

Step 3: Replace Tank Cap by turning clockwise to screw back in place. DO NOT OVER-TIGHTEN. Place tank back on humidifier base.

RESET: When your humidifier is out of water, the refill light will illuminate. Turn the humidifier off, wait 15 minutes, refill Tank, and turn humidifier back on.

Operating Instructions V750 Series

Power: With the power switch in the OFF position (O), plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way. DO NOT plug in humidifier with wet hands to avoid electric shock.

Output: Set output control to high ( ) or low ( ).

Indications that your humidifier is operating are that the green nightlight on the control knob will illuminate, and after 1-2 minutes, your humidifier will produce a visible steam.

Humidity Level: Once you have reached a comfortable humidity level, your humidifier should be turned to the low setting. A comfortable humidity level is between 40-60%. To monitor your humidity level, it is recommended you use a hygrometer such as the Vicks V70 or V70-CAN Model (not included). If you notice condensation on the walls or windows, you should turn your humidifier off as your humidity level is too high.

CAUTION: DO NOT remove the Mist Chimney, Removable Tray, Water Tank, or Medicine Cup when the humidifier is in use or for at least 20-30 minutes after the unit has been turned off and unplugged.

CAUTION: WHEN MOVING HUMIDIFIER, TURN HUMIDIFIER OFF, UNPLUG, AND WAIT 20-30 minutes. DO NOT OPERATE YOUR HUMIDIFIER WITHOUT THE TANK IN PLACE OR IF THE UNIT IS EMPTY. DO NOT OPERATE YOUR HUMIDIFIER WITHOUT THE MIST CHIMNEY, REMOVABLE TRAY, OR MEDICINE CUP PROPERLY ASSEMBLED.

Using Liquid Inhalant (Not included)

Liquid inhalants such as Vicks VapoSteam can be used in the medicine cup. ONLY USE LIQUIDS THAT ARE RECOMMENDED FOR THIS TYPE OF HUMIDIFIER.

  1. Add 1 TB (Table Spoon) inhalant to the medicine cup.
  2. NOTE: Some residue from inhalant may be left in the medicine cup after use. With the humidifier turned off, unplugged, and cooled for at least 20 minutes, gently wipe residue from the medicine cup.
  3. DO NOT ADD LIQUID INHALANTS OR ANY ADDITIVES OTHER THAN THOSE RECOMMENDED BY THE HUMIDIFIER MANUFACTURER TO THE WATER. DOING SO CAN HAVE ADVERSE EFFECTS ON THE HUMIDIFIER.

Using Scent Pads

  1. You can use Vicks Scent Pads, VSP-19 Series, VBR-5 Series, VVP-6 Series with your humidifier to provide up to 8 hrs of soothing vapors (one sample pad included).
  2. Open scent pad by tearing notch on top of pad bag. DO NOT touch pad with hands. If pad is touched, do not rub face as it may cause eye irritation.
  3. Open Scent Pad Door located on the rear of the unit. Insert scent pad with angled end facing towards the product. Close door.
  4. Your scent pad will last 8 hrs. After 8 hrs., open door, remove old scent pad and discard. If you choose to continue using scent pads, follow steps 2 and 3.

Scent Pad Recommended Usage:

Scent Pad Ingredients: VSP-19, VSP-19FP, VSP-19-CAN & VVP-6: Eucalyptus Oil, Menthol, Glycol, Cedar Leaf Oil & Others.

Weekly Care And Cleaning

NOTE: All maintenance should be done in the kitchen or bathroom on a water-resistant surface. To properly clean your humidifier, we recommend the process of scale removal and disinfecting shown on pages 6 and 7 of this manual.

DISHWASHER SAFE: The following parts are TOP RACK dishwasher safe for residential dishwashers operating at temperatures below 70°C/158°F:

Run the dishwasher on the light duty or normal cycle. Do not wash with soiled articles/dishes. DO NOT USE DETERGENTS. If you use your dishwasher, you will not need to follow the disinfecting and scaling procedure.

NOTE: Do not place parts on the lower rack of the dishwasher. Doing so could cause damage to the humidifier parts and dishwasher.

THE MAIN HOUSING AND WATER TANK ARE NOT DISHWASHER SAFE. Placing these parts in the dishwasher will damage your humidifier and render it unable to operate properly.

Scale Removal Directions:

  1. CAUTION: ALWAYS TURN OFF THE POWER SWITCH AND DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET BEFORE CLEANING. If the humidifier has recently been in use, wait 20-30 minutes for the unit to cool before beginning the cleaning process.
  2. Remove Water Tank and empty.
  3. Disassemble the Mist Chimney by gently pushing on the blue release latch and pulling up.
  4. Remove Removable Tray by pushing on the blue Removable Tray Lift Tab and gently pulling tab up.
  5. Fill Water Tank and Base with 1 cup of vinegar.
  6. Wipe Mist Chimney, Medicine Cup, and Removable Tray with solution.
  7. Soak Heating Element for 15-20 minutes, then gently scrub with a soft brush to remove mineral deposits. DO NOT USE HARD BRUSHES, STEEL WOOL, OR OTHER HARD ABRASIVES ON THE HEATING ELEMENT. DOING SO WILL DAMAGE THE HEATING ELEMENT. Rinse Tank, Base, Mist Chimney, Removable Tray, and Medicine Cup until the smell of the solution is gone.
  8. CAUTION: DO NOT IMMERSE BASE IN WATER.
  9. To clean the scent pad area, gently wipe out the scent pad heater area with a soft damp cloth. DO NOT USE VINEGAR OR BLEACH SOLUTION TO CLEAN THIS AREA.

Follow with disinfecting directions on page 8.

Disinfecting Directions – Disinfect Following Scale Removal

  1. Add 1 Teaspoon of bleach to 1 gallon (3.8L) water.
  2. Add ½ to ¾ gallon (1.9L-2.8L) of water/bleach solution to the heating element area of the Main Housing and Water Tank.
  3. Follow steps 6 and 7 from the scaling section (page 7).

NOTE: Please be careful of clothing, rugs, and other non-bleach resistant materials when disinfecting. Spilling bleach on clothing, rugs, and certain surfaces may cause damage.

NOTE: Using more than 1 teaspoon of bleach per gallon (3.8L) of water will result in damage to your humidifier.

Re-Assembling

Step 1: Push blue Tab to the open position. Place Water Tray and then Mist Chimney back on the humidifier. Make sure they are sitting securely and blue latch is in the closed position.

Step 2: Snap Medicine Cup back in place if removed.

Step 3: Put Tank Cap back on Water Tank and place Water Tank back on unit.

End-Of-Season Care And Storage

When the humidifier will not be used for at least one week or more, or at the end of the season, follow the CLEANING instructions, starting on page 6.

At the end of the season, remove any accessories from the humidifier.

Dry the humidifier completely before storing. DO NOT store with water inside the Main Housing Water Reservoir or Water Tank.

Pack unit in original carton and store in a cool, dry location.

Consumer Relations

We are here to help.

Call us toll-free at: 1-800-VAPOR-1-2 (1-800-827-6712)

Visit: www.VicksHumidifiers.com/contact-us

Please be sure to specify Model number V750.

NOTE: If you experience a problem, please contact consumer relations first or see your warranty. Do not return to the original place of purchase. Do not attempt to open the electrical housing yourself, doing so may void your warranty and cause damage to the humidifier or personal injury.

Troubleshooting

Problem Possible Cause Solution
• Power Switch is set to On" and Nightlight is off • Unit not plugged in
• No power at outlet
• Plug unit in
• Check circuits, fuses, test outlet
• Little or no mist is produced • No water in Tank
• Unit is not level
• Mineral deposits on Heater Element or Removable Tray
• Water Tank was washed with detergent
• Fill Water Tank
• Place on a level surface
• Follow Cleaning Instructions on Pages 6-8
• Rinse thoroughly with clean water
• Reset Light illuminated • Water Tank is empty
• Unit not reset after refill
• Refill Water Tank
• Follow Reset Procedure
• Water overflows from Reservoir • Tank may be leaking
• Tank Cap is not tight
• Check the Tank for leaks and replace if necessary
• Tighten Tank Cap
• Condensation forms around humidifier or windows • Mist Intensity is set too high for room size or pre-existing humidity level • Turn unit off or decrease mist output to low setting or open door to the room

NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit. Customer failure to follow these instructions may void the warranty.

Electrical Ratings

The Vicks V750 Series Model is rated at 120V, 60 Hz.

2 Year Limited Warranty

YOU SHOULD FIRST READ ALL INSTRUCTIONS BEFORE ATTEMPTING TO USE THIS PRODUCT.

A. This 2 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.

C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

D. This warranty does not cover the filters, pre-filters, UV bulbs, or other accessories (if included) except for material or workmanship defects.

Call us toll-free at 1-800-827-6712 or contact us at www.VicksHumidifiers.com/contact-us. Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

© 2023 All rights reserved. • Todos los derechos reservados.

Kaz USA, Inc., a Helen of Troy Company • una Empresa de Helen of Troy

400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752

www.VicksHumidifiers.com

Certain trademarks used under license from The Procter & Gamble Company or its affiliates. • Ciertas marcas registradas utilizadas bajo licencia de The Procter & Gamble Company o sus afiliados.

For Responsible recycling, please visit:

Para reciclar responsablemente, por favor visite:

RECYCLE NATION

www.RecycleNation.com

Models: V750, V750 Series WarmMist Humidifier, WarmMist Humidifier, Humidifier

File Info : application/pdf, 24 Pages, 6.71MB

PDF preview unavailable. Download the PDF instead.

v750 om a001200r3 r5 14nov22 manual

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Macintosh)

Related Documents

Preview Vicks V750 Series Warm Mist Humidifier Use and Care Manual
User guide for the Vicks V750 Series Warm Mist Humidifier by Kaz. Covers setup, operation, safety, cleaning, and troubleshooting for optimal home comfort.
Preview Vicks Filtered Cool Mist Humidifier: Use and Care Manual
A comprehensive guide to operating, maintaining, and troubleshooting your Vicks Filtered Cool Mist Humidifier (VEV400 Series). Includes safety instructions, setup, operation, filter care, cleaning procedures, and warranty information.
Preview Vicks Filter Free Ultrasonic Cool Mist Humidifier Use and Care Manual
Comprehensive guide for the Vicks Filter Free Ultrasonic Cool Mist Humidifier (Models VUL525/VUL545), covering setup, operation, safety instructions, maintenance, troubleshooting, and warranty information.
Preview Vicks Mini Cool Mist Ultrasonic Humidifier User Manual
User manual for the Vicks Mini Cool Mist Ultrasonic Humidifier (Model VUL525E), providing instructions on operation, safety, cleaning, and maintenance. Learn how to use your Vicks humidifier effectively and safely.
Preview Vicks 3-in-1 SleepyTime™ Ultrasonic Humidifier, Diffuser, Night-Light - Use and Care Manual
Comprehensive use and care manual for the Vicks 3-in-1 SleepyTime™ Ultrasonic Humidifier, Diffuser, and Night-Light (Model VUL500C). Includes setup, operation, filling, cleaning, troubleshooting, and warranty information.
Preview Vicks V1200 Personal Steam Inhaler Use and Care Manual
This manual provides instructions for the Vicks V1200 Personal Steam Inhaler, including care, cleaning, safety precautions, and usage guidelines. It details how to use the steam inhaler for relief from cough, cold, and congestion symptoms, and how to use optional Vicks VapoPads.
Preview Vicks EasyCare+ Top Fill Filter Free Humidifier Use and Care Manual
This manual provides instructions for the Vicks EasyCare+ Top Fill Filter Free Humidifier, including setup, operation, cleaning, and troubleshooting.
Preview Vicks Digital Plus Thermometer V906CAV1: User Manual and Instructions
Comprehensive guide to operating, cleaning, and maintaining the Vicks Digital Plus Thermometer (Model V906CAV1) for accurate oral, rectal, and axillary temperature readings.