Vicks 3-in-1 SleepyTime™ Ultrasonic Humidifier - Diffuser - Night-Light

Use And Care Manual

Introduction

This humidifier adds water vapour to the surrounding air. If you have any questions about the operation of your Vicks 3-in-1 SleepyTime™ Humidifier, call our toll-free Consumer Relations line at 1-800-VAPOR-1-2 or e-mail us at ConsumerRelations@HelenofTroy.com.

IMPORTANT! READ AND SAVE THESE INSTRUCTIONS

Model VUL500C

Important Safety Instructions

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS APPLIANCE

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:

  1. The appliance should ALWAYS be placed on a firm, flat, waterproof surface at least four feet (1.2 m) away from bedside, 12 inches (30 cm) from the wall and out of reach of children and pets. Be sure the appliance is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being a tripping hazard; doing so may result in personal injury or property damage.
  2. The appliance should not be left unattended in a closed room. Leave room door partly open. DO NOT aim Mist Outlet directly at walls, furniture and bedding.
  3. Before using the appliance, extend the cord and inspect for any signs of damage. DO NOT use the unit if the cord has been damaged. DO NOT operate with power cord coiled or twist tie in place.
  4. The appliance has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  5. To avoid fire or electric shock hazard, plug the appliance directly into a 120V AC electrical outlet. To avoid risk of fire, electric shock or personal injury, DO NOT use an extension cord or power strip.
  6. The appliance should ALWAYS be unplugged and emptied when not in operation or while being cleaned. Shut off and unplug humidifier before moving. DO NOT move or tilt humidifier while it is in operation. Plug and unplug unit with dry hands. NEVER pull by cord.
  7. Appliance requires regular cleaning. Refer to and follow cleaning instructions.
  8. DO NOT operate outdoors; this appliance is intended for indoor residential use only.
  9. DO NOT cover or insert objects into any openings on the unit.
  10. DO NOT attempt to repair or adjust any electrical or mechanical functions on this appliance. Doing so will void your warranty.
  11. DO NOT place in direct sunlight, high temperature areas or near computers or sensitive electronic equipment.
  12. DO NOT touch the nebulizer while the unit is plugged in as burns could result.
  13. DO NOT touch skin with exposed VapoPad or place VapoPad on furniture, fabric, bedding or plastic.
  14. DO NOT add any medications (e.g. Kaz Inhalant or Vicks VapoSteam) into Mist Outlet, Base, Water Reservoir or Water Tank.

Product Overview

The Vicks 3-in-1 SleepyTime™ Humidifier (Model VUL500C) includes the following parts:

VUL500C Accessories (Not Included)

The following optional accessories work great with your humidifier:

Setting Up Your Humidifier

Follow these steps to set up your humidifier:

  1. Remove packaging materials. Keep instructions.
  2. Remove twist tie and extend power cord.
  3. Place on a firm, level, water resistant surface a minimum of 12" (30cm) from any walls.

Filling/Refilling

NOTE: Tank should be carried using two hands. One hand using carrying handle located on tank top and other hand supporting the base of the tank.

Helen of Troy will not accept responsibility for property damage caused by water spillage. This Humidifier holds 0.6 gallon (2.3L) of water (tank and reservoir combined). Always turn the humidifier off before removing the Water Tank.

  1. Remove Tank and turn upside down.
  2. Remove Tank Cap in the direction of the open lock symbol.
  3. Fill Tank with cool water. DO NOT fill with warm or hot water.
  4. Securely replace Tank Cap, aligning arrow to lock symbol.
  5. Place Tank back on Base.

CAUTION: USE CARE WHEN HANDLING WATER TANK TO AVOID UNNECESSARY IMPACT. BANGING OR DROPPING THE WATER TANK COULD RESULT IN DAMAGE TO THE TANK THAT WILL CAUSE LEAKING.

Operating

  1. Power: With the Power Knob in the off position, plug humidifier into a polarized 120V outlet. CAUTION: TO AVOID ELECTRIC SHOCK DO NOT PLUG HUMIDIFIER INTO OUTLET WITH WET HANDS.
  2. Humidity Output: Turn the Power Knob to highest setting.
  3. Humidity Level: When a comfortable humidity level is reached turn Power Knob to a lower setting. A comfortable humidity level is between 40-60%. Consider using a humidity monitor to display current room humidity and temperature. CONDENSATION: If you notice condensation on the walls, windows or around unit, your humidity level is too high. Open doors to the room or turn off humidifier until humidity level drops.
  4. Mist Nozzle: The 180° mist nozzle directs mist output away from walls, furniture and bedding.

CAUTION: BEFORE MOVING HUMIDIFIER, TURN OFF, UNPLUG AND EMPTY THE HUMIDIFIER.

Using Vicks VapoPads

Your humidifier can be used with Vicks VapoPads to provide up to 8 hours of soothing comfort per pad. One free sample of the Vicks Soothing Menthol VapoPad is included with your humidifier. To use your unit with Vicks VapoPads:

  1. Open VapoPad Door.
  2. Open VapoPad by tearing notch on pad bag. DO NOT touch pad with hands. If pad is touched, DO NOT rub face or eyes as it may cause irritation.
  3. Insert up to 2 Vicks VapoPads with angled end facing towards the product. Close door.
  4. After 8 hours, discard scent pads.

To continue using scent pads, repeat steps 1-4.

VapoPad Recommended Usage:

Operating the Night-Light by Touching the Button

Operating with Essential Oils

To use essential oils in your humidifier, add a few drops of your favourite essential oil(s) to the water in the Tank and replace the Cap. DO NOT operate without water. ONLY use 100% natural essential oils; use of other oils may cause damage to the Humidifier. ALWAYS reference the essential oil labeling for usage and dosage instructions.

NOTE: The Tank and Reservoir are made of oil-proof materials but other parts of the Humidifier are not. Essential oils should only be allowed in the Tank and Reservoir. If any oils spill outside of the Tank or Reservoir, be sure to wipe down gently with a wet paper towel and then dry gently with a dry paper towel.

Water Quality and Your Humidifier

High mineral content in your water, also known as "hard water" may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. This mineral residue is commonly referred to as "white dust." The higher the mineral content or hardness of your water, the greater the potential that you may have white dust. "White dust" is not a result of a defect or flaw in the humidifier. It is a result of the amount of minerals suspended in the water you are using. If you live in a hard water area the use of distilled water will minimize the production of white dust.

Weekly Cleaning

To properly clean your humidifier we recommend the separate processes of Scale Removal and Disinfecting shown below. These two processes must be performed separately. All maintenance should be done in the kitchen or bathroom on a water resistant surface near a faucet. DO NOT wash any components of this humidifier in the dishwasher.

Instructions for Scale Removal

  1. Turn off and unplug the humidifier.
  2. Remove Water Tank from Base. Remove Tank Cap, taking care that black rubber Cap Seal does not come off. Empty water from Water Tank and Base.
  3. If accessories are installed, remove them and set aside. DO NOT clean accessories. This will damage the accessories.
  4. Add 2 cups of undiluted distilled white vinegar to Water Tank. Replace Tank Cap and swish vinegar solution around in Tank. Place Tank on Base. Vinegar solution will drain into Water Reservoir and loosen mineral buildup (scale) on Nebulizer and Float as they soak in the solution. It will also loosen scale on bottom of Water Tank.
  5. Soak for 15-20 minutes.
  6. After soaking, unlock Tank Cap and pour solution out in sink. Pour solution from Water Reservoir out in sink. Wipe Nebulizer and Float with soft cloth to remove loosened mineral deposits.
  7. Rinse Water Reservoir and Water Tank until smell of vinegar (for Scale Removal process) or bleach solution (for Disinfecting process) is gone. Make sure water does not enter the fan opening (vented opening on right side of Reservoir) or Power Knob.

CAUTION: DO NOT SUBMERGE BASE IN WATER. DOING SO WILL DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY.

Instructions for Disinfecting

Follow Steps 1-3 in Scale Removal Instructions in previous section.

  1. For Step 4: Add ½ tsp of bleach to 1½ gallon (1.9L) of water and add to Tank. Replace Tank Cap. Swish solution around in Tank. Place Tank on Base. Bleach solution will drain into Reservoir and will disinfect Reservoir and other components as they soak.
  2. See steps 5-7 in Scale Removal Instructions in previous section to complete Disinfecting process.

NOTE: Using more than ½ tsp of bleach to ½ gallon of water may result in damage to your humidifier.

NOTE: DO NOT mix vinegar and bleach solutions together. Scale Removal and Disinfecting must be done separately.

End-Of-Season Care And Storage

Follow the CLEANING instructions when the humidifier will not be used for at least one week, or at the end of the season. At the end of the season, remove any accessories used with the humidifier and allow the humidifier and accesories to dry completely before storing. DO NOT store with water inside the Base, Reservoir or Tank. Pack unit safely and store in a cool, dry location.

Consumer Relations

We are here to help.

Call us toll-free at: 1-800-VAPOR-1-2 (1-800-827-6712)

Email: ConsumerRelations@HelenofTroy.com

Please be sure to specify Model number VUL500C.

NOTE: if you experience a problem, please contact consumer relations first or see your warranty. Do not return to the original place of purchase. Do not attempt to open the electrical housing yourself, doing so may void your warranty and cause damage to the humidifier or personal injury.

Electrical Ratings

The Vicks VUL500C model is rated at 120V, 60 Hz.

Troubleshooting

If your humidifier is not working properly, refer to the following:

Problem Possible Cause Solution
Power Knob is turned "on" and the power light is off
  • Unit not plugged in
  • No power at outlet
  • Plug unit in
  • Check home circuits, fuses, test outlet
Power is on and little or no mist is produced
  • No water in tank
  • Unit is not level
  • Mineral deposits on Nebulizer
  • Power setting may be too low
  • Water Tank or Base were washed with detergent
  • Fill Water Tank with cool water
  • Place on a level surface
  • Clean Nebulizer (refer to Weekly Care & Cleaning instructions)
  • Turn the Power Knob to increase output
  • Rinse thoroughly with clean water until there is no foam or smell of cleaning solution
Water overflows from Reservoir
  • Tank may be damaged
  • Tank Cap is not tight
  • Tank Cap Seal may be missing
  • Check the Tank for any cracks or damage. and replace if necessary
  • Close Tank Cap to lock position
  • Check to see if Cap Seal is attached to Tank Cap. If not, contact Consumer Relations
Condensation forms around humidifier or on windows and walls
  • Mist Intensity is set too high for room size or pre-existing humidity level
  • Humidifer may be too close to wall or window
  • Decrease mist output to lower setting or open door to the room
  • Move humidifier away from wall or point Mist Outlet away from wall or window
No Night-Light display
  • Light Button is not pressed
  • Press the Light Button to turn on the colour changing light and press a second time to stop on the current colour

NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit. Customer failure to follow these instructions may void the warranty.

2 Year Limited Warranty

YOU SHOULD FIRST READ ALL INSTRUCTIONS BEFORE ATTEMPTING TO USE THIS PRODUCT.

A. This 2 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.

C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

D. This warranty does not cover the filters, pre-filters, UV bulbs or other accessories (if included) except for material or workmanship defects.

Call us toll-free at: 1-800-VAPOR-1-2 (1-800-827-6712)

E-mail: ConsumerRelations@HelenofTroy.com

Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

Models: VUL500C 3in1 SleepyTime Ultrasonic Humidifier Diffuser Night Light, VUL500C, 3in1 SleepyTime Ultrasonic Humidifier Diffuser Night Light, Ultrasonic Humidifier Diffuser Night Light, Humidifier Diffuser Night Light, Diffuser Night Light, Night Light, Light

File Info : application/pdf, 11 Pages, 3.82MB

PDF preview unavailable. Download the PDF instead.

VUL500C-Owners-Manual

References

Adobe InDesign 17.2 (Macintosh) Adobe PDF Library 16.0.7

Related Documents

Preview Vicks Filter Free Ultrasonic Cool Mist Humidifier Use and Care Manual
Comprehensive guide for the Vicks Filter Free Ultrasonic Cool Mist Humidifier (Models VUL525/VUL545), covering setup, operation, safety instructions, maintenance, troubleshooting, and warranty information.
Preview Vicks VEV400 Filtered Cool Moisture Humidifier: Use and Care Manual
Comprehensive guide for the Vicks VEV400 Filtered Cool Moisture Humidifier, covering setup, operation, maintenance, troubleshooting, and warranty information.
Preview Vicks Filtered Cool Mist Humidifier: Use and Care Manual
A comprehensive guide to operating, maintaining, and troubleshooting your Vicks Filtered Cool Mist Humidifier (VEV400 Series). Includes safety instructions, setup, operation, filter care, cleaning procedures, and warranty information.
Preview Vicks Warm Mist Humidifier V750 Use and Care Manual
This manual provides instructions for the use and care of the Vicks Warm Mist Humidifier, Model V750. It includes safety instructions, operating procedures, cleaning and maintenance guidelines, troubleshooting tips, and warranty information.
Preview Vicks Mini Cool Mist Ultrasonic Humidifier User Manual
User manual for the Vicks Mini Cool Mist Ultrasonic Humidifier (Model VUL525E), providing instructions on operation, safety, cleaning, and maintenance. Learn how to use your Vicks humidifier effectively and safely.
Preview Vicks No Touch 3-in-1 Thermometer (VNT200) - Instruction Manual
This document provides comprehensive instructions for the Vicks No Touch 3-in-1 Thermometer (VNT200), covering its features, safe usage, temperature taking, troubleshooting, care, and specifications. It is designed for home use to accurately measure body, food, and bath temperatures.
Preview Vicks V1200 Personal Steam Inhaler Use and Care Manual
This manual provides instructions for the Vicks V1200 Personal Steam Inhaler, including care, cleaning, safety precautions, and usage guidelines. It details how to use the steam inhaler for relief from cough, cold, and congestion symptoms, and how to use optional Vicks VapoPads.
Preview Vicks Portable Waterless Diffuser VH1800EU: Use and Care Manual
This manual provides comprehensive instructions for the Vicks Portable Waterless Diffuser (model VH1800EU), covering safety guidelines, operation, maintenance, troubleshooting, and warranty information.