Temperzone Econex Pro Packaged Units
Introduction
The Econex Pro Packaged Units by Temperzone offer a new level of innovation in humidity control, intuitively managing space temperature and humidity while maintaining optimum efficiency. These units are designed to be a high-tech game-changer, capable of operating with or without external intervention thanks to their in-built Adaptive software. This software reacts to environmental surroundings and changes operation to continuously generate desired comfort outcomes, understanding consumer needs and prevailing conditions.
Designed exclusively using Temperzone's in-house R&D expertise, the Econex Pro represents cutting-edge technology aimed at transforming sustainable air conditioning solutions. With wide capacity ranges, they efficiently react to changing building heat loads, making them ideal for a variety of temperature and humidity-sensitive environments such as supermarkets, shopping centres, and schools and universities.
[Image: A white, rectangular Temperzone Econex Pro packaged air conditioning unit with visible components and fans on top, set against a modern interior background.]
Heating Capacity: 17.3kW - 203kW
Cooling Capacity: 16.8kW - 207kW
Key Accolades: Proudly Made in Australia, ARBS Winner 2022 Product Excellence Award.
Features
- Intelligent Unit Controller: Provides multiple operation modes including comfort and dehumidification; offers Turn Key / Stand Alone control.
- Low GWP Refrigerant: Utilizes R32 refrigerant, which has a significantly lower Global Warming Potential (GWP) than R410A.
- Variable Speed Fans: EC Axial Condenser fans provide greater efficiency and system control.
- EC Plug Fans: Precisely adjust airflow in response to changes in static pressure.
- Inverter Compressors: Enable a wide capacity range and superior part-load performance.
- EEV Systems: Electronic Expansion Valves (EEVs) offer optimum control of superheat for outstanding comfort and humidity control.
- Corrosion Resistant Design: Features marine-grade surface protection and epoxy-coated coils for durability.
- Reheat Coil Option: Integrated hot gas bypass reheat coil available for specific models (1410 to 2110).
- Humidity Intelligence: Automatically selects operation modes to maintain optimal comfort conditions.
- Wide Temperature Operating Range: Operates effectively in ambient temperatures from -10°C to +50°C.
- Louvred Guards: Aesthetic guards protect coils from damage.
- BMS Connectivity: BACnet via TC/IP and Modbus over RS-485 or TC/IP are available as standard.
Lower Global Warming Potential Air Conditioning
OPA Econex R32 refrigerant units offer a significant reduction in Global Warming Potential (GWP) per kW of cooling or heating, achieving a 71% - 81% reduction compared to R410A systems (GWP 2088). With a smaller refrigerant charge and a GWP of 675, these units contribute to environmental sustainability.
As higher GWP refrigerants face increasing costs due to emissions tax levies, specifying R32 systems like Econex Pro represents a significant reduction in future costs associated with owning and maintaining these systems.
[Diagram: Comparative chart showing potential carbon emissions attributed to refrigerant for 'Older Model' vs. 'Econex' units, illustrating reductions of 78%, 80%, and 81% CO2 Tonnes.]
Superior Comfort Control
Econex Pro units provide superior comfort control by considering indoor and outdoor humidity levels, making autonomous decisions to satisfy setpoint conditions. They offer multiple autonomous comfort modes:
- Cooling - High Latent
- Cooling - High Sensible
- Cooling - Standard
- Cooling - Reheat* (*available with optional reheat coil)
- Heating - Dehumidification
- Heating - Standard
- Comfort Zone - Fan only
Unlike traditional systems that rely solely on temperature setpoints, Econex Pro's 7 modes of comfort are designed around dewpoint levels on a psychrometric chart. This allows for precise comfort needs by managing moisture and temperature within specific limits.
The adaptive software logic ensures the system automatically switches between modes as required. For instance, during hotter, wetter months, 'Cooling - Reheat' mode might operate. As ambient conditions change and sensible heat load increases, the system may transition to 'Cooling - High Latent' or 'Cooling - Standard' modes, continuously optimizing for comfort and minimizing energy consumption.
[Diagram: Psychrometric chart illustrating traditional control (Heating, Cooling) versus Econex Pro control (Dehum + Reheat, Heating + Dehum, Comfort) with setpoints and comfort zones.]
[Diagram: Graphs showing 'Moisture Removal' and 'Sensible' load over time, illustrating different modes like High Latent, High Sensible, and Standard.]
Quick and Easy Set-Up: Pre-set optimization and pre-programmed advanced control logic ensure effective and efficient operation out-of-the-box.
Seasonal Energy Efficiency
The OPA Econex Pro, equipped with multiple independent refrigeration circuits, inverter compressors, and EC plug fans, is engineered to maximize part-load efficiency. Its Absolute Autonomous Control provides accurate temperature and humidity control under all conditions by precisely managing evaporating and supply air temperatures.
Inverter Compressors: Offer ultra-high efficiency with a 16:1 turn-down ratio, soft starting to reduce power consumption at startup, and reduced start/stop cycles for longer life. This technology matches capacity to load, avoiding temperature fluctuations and minimizing energy input.
Extreme Weather Operation: Designed for harsh conditions, these units operate reliably in ambient temperatures ranging from -10°C to +50°C.
[Diagram: Bar chart comparing Total Cooling Seasonal Performance Factor (TCSPF) for OPA 2110 Inverter vs. OPA 2000 Fixed, showing 5.32 vs 3.38.]
Seasonal Energy Efficiency (SEER): Econex Pro Inverter technology delivers superior seasonal performance. Compared to older models (e.g., ECO OPA 960), the OPA 970 Econex Pro demonstrates considerably higher seasonal energy efficiency factors (TCSPF and SEER) and offers significant energy savings (kWh) in annual cooling consumption.
[Diagram: Bar charts comparing EER and TCSPF for OPA 970 Econex Pro vs. ECO OPA 960 across different climate zones (Cold, Hot, Mixed) and ambient temperatures.]
[Diagram: Pie charts illustrating Energy Consumption - Annual Cooling MWh for OPA 960 ECO and OPA 970 Econex Pro, showing lower consumption for Econex Pro.]
Energy Saving Technology
Intelligent system control technology provides leading energy efficiency with precision control of the air conditioner's refrigeration system. The high-efficiency EC fan motors are up to 50% more energy efficient than belt-drive or AC motor alternatives, enabling quiet operation with slow ramp-up and no sudden noise changes.
EC Fan Technology Benefits:
- Programmable for exact airflow
- High static pressure
- Enables variable airflow operation
- Longer motor life due to lower running temperatures
- Lower maintenance and commissioning costs
- Slow ramp-up for quiet operation
- Longer bearing life due to soft start
EC fans contribute to overall application efficiency by keeping refrigerant pressure constant, reducing compressor loads and optimizing efficiency within the compressor's operating envelope.
EC Plug Fans: The unit's integrated electronics continuously monitor static pressure and adjust fan speed accordingly for accurate and efficient control. Fan speed can also be controlled via external signals (input or Modbus).
EC Plug Fan Benefits:
- Up to 50% more efficient than AC fan technology
- High static pressure
- Minimized power consumption under optimized floating head pressure control
- Quiet operation mode
[Diagram: Line graph comparing Input Power (%) vs. Air Flow (%) for AC Motor vs. EC Motor, showing EC Motor's higher efficiency.]
[Image: Close-up view of an EC Plug Fan with its motor and wiring.]
Reliability & Durability
Econex Pro units are designed to be highly durable and suited to the harshest environmental conditions, featuring:
- 1. Corrosion Resistance: Highly corrosion-resistant epoxy coated coils.
- 2. Material Quality: Marine-grade pretreatment and polyester powder coated galvanised steel construction.
- 3. Drainage: Deep and wide indoor coil draintray with brass hex socket removal connection.
- 4. Protection: Louvre guards for added protection against severe weather and UV damage.
- 5. Fasteners: SKT coated screws offer higher corrosion resistance than 316 stainless steel.
- 6. Compartmentalization: Isolated compressor and electrical compartments for reduced noise and improved weatherproofing.
- 7. Drainage Design: Sloped outdoor section allows water from rain and de-ice to drain effectively.
- 8. Drain Tundishes: Outdoor section drain tundishes with spigots for PVC pipe connections.
- 9. Service Access: Easy access hinged service doors with door stays for maintenance and filter access.
[Image: A Temperzone Econex Pro unit highlighting its robust construction and components.]
Electronic Expansion Valves (EEV)
EEVs optimize refrigeration systems by ensuring the evaporator coil is fully utilized at all times, leading to increased energy savings. They also allow for lower discharge pressures based on ambient conditions by increasing EC condenser fan speed, resulting in even higher savings.
EEV Benefits:
- Enable improved efficiency and reduced operating costs at part-load conditions.
- Facilitate maximized energy savings during shoulder seasons when air conditioning systems often run at part-load.
[Diagram: Graph showing the relationship between Ambient Temperature and EEV performance (Accurator vs. EEV) with efficiency curves.]
Incorporated Adaptive Technology & Control Innovation
With pre-programmed optimization and an in-built controller display, Econex Pro is designed for quick and easy set-up. The incorporated adaptive technology ensures flexibility, versatility, and user-friendliness.
Advanced Controller & System Control:
- Full Unit Operation: Fully integrated controls manage every function of the unit.
- Sensor Inputs: Configurable for most commercially available sensors (room, return/supply air, outdoor air).
- Fan & Compressor Information: Motor information available via Modbus communications and on-unit display.
- Supply Fan Control: Ability to turn supply fans off when there is no capacity demand.
- Refrigeration System Information: Available via display and optionally via BACnet and Modbus communications.
- Mixed Air Sensor: Input available or theoretically calculated.
- Indoor Fan Control: Can be controlled to a constant speed or constant airflow using built-in airflow measurement.
- Setback Functionality: Allows room temperature setback during unoccupied periods to maintain a wider space temperature range.
- Fan Speed Reduction: Reduces indoor fan speed during unoccupied times to minimize energy use.
- Scheduling: Daily programmable on/off operation with up to 4 events per day, 7 days a week, plus holidays.
- Time Clock: Individual time clock for night mode or unoccupied mode, independent of the 24/7 clock.
- Economiser Control: Optional control of outdoor air and return air dampers using an enthalpy-based algorithm.
- Night Mode: Reduces noise levels when activated.
Key Control Innovations include: Intelligent Humidity Control, Automatic System Mode Operation, Power Monitoring (individual compressors/fans), RH & Temperature Measurement and Control, Tempering Control, System Management (oil/refrigerant), Adaptive Compressor Control, BMS Connectivity (Modbus/BACnet), Programmable Time Clock, Multi-level Protection, Service Interface Screen with data logging, Adjustable Indoor Fan Airflow Set-point, and Quick Start user settings.
[Image: Close-up of the Econex Pro unit's advanced controller display.]
Configurable Options
Econex Pro offers configurable mechanical and control options for convenient integration into projects and applications.
- Economy Dampers: Built-in function to control economiser dampers (external or factory fitted). Uses temperature and humidity sensors to determine optimal air source based on measurements and space conditions, controlling via enthalpy method.
- Spill Air: Available as a built-in or factory-fitted option for bottom return air handling configurations. Modulates relief pressure in the return air chamber to prevent over-pressurization of the conditioned space, with spill air damper controlled proportionally to the fresh air inlet damper.
- CO2 Sensing: An optional feature that opens dampers to allow more outdoor air when ppm levels drop below a pre-set level, prioritizing indoor air quality.
- After Hours Operation: Compatible with aftermarket after-hours pushbuttons, allowing direct wiring to the advanced controller for pre-configured after-hours operation.
- Reheat Coils: In-built reheat coils are available for humidity control, featuring an integrated reheat system with a DX reheat coil and bi-polar modular reheat valves for artificial sensible heat.
- Modular Reheat Valve: A fully modulating valve with self-calibration and a supply air sensor for precise control of delivered air when an optional reheat coil is supplied.
- Heat Reclaim Coil: Facilitates the use of waste heat (e.g., from refrigeration racks) for first-stage heating. Controls a modulating water valve for capacity control of a water-based heat reclaim coil, which is externally located.
[Image: Illustrations of Economy Dampers, Spill Air system, and CO2 Sensing setup.]
Flexible Handling Options
Flexible handing configurations are available to suit various applications. Standard OPA 680 - 2110 units are supplied with left-hand supply air (when facing the spigots). Alternative configurations for supply air and return air openings are available in standard or opposite hand configurations.
Configuration Without Economiser:
Supply Air | Return Air - Without Economiser | |||
---|---|---|---|---|
Top | Front | Down | Side | |
Top | • | • | • | • |
Front | • | • | • | • |
Down | • | • | • | • |
Side | • | • | • | • |
Configuration With Economiser:
Supply Air | Return Air - With Economiser | |||
---|---|---|---|---|
Top | Front | Down | Side | |
Top | • | • | • | • |
Front | • | • | • | • |
Down | • | • | • | • |
Side | • | • | • | • |
[Image: Diagrams illustrating Right Hand Configuration (Opposite Hand) and Left Hand Configuration (Standard Hand) of the unit.]
Optional Parts Include: Filters (EU4/G4 disposable), Economy dampers, Economy cycle control, Supply and return air handlings, Economy cycle control enthalpy, Reheat coil*, Outdoor air sensor, Temperature and humidity sensors, CO2 Sensor, Averaging sensor module. (*Available on OPA 1410-2110)
Technical Specifications
The Econex Pro Range offers various models with detailed technical specifications:
Model | OPA 171 PRO | OPA 211 PRO | OPA 680 PRO | OPA 820 PRO | OPA 970 PRO | OPA 1410 PRO | OPA 1710 PRO | OPA 2110 PRO |
---|---|---|---|---|---|---|---|---|
Total (Gross) Capacity kW* Cooling | 5.3 ~ 20.3 | 7.3 ~ 25.3 | 14.4 ~ 79.0 | 11.2 ~ 88.3 | 16 ~ 102 | 11.8 ~ 189 | 14.6 ~ 205.8 | 27 ~ 239 |
Total (Gross) Capacity kW* Heating | 4.0 ~ 20.7 | 5.8 ~ 26.4 | 11.2 ~ 88.3 | 8.3 ~ 72.3 | 10.0 ~ 97.0 | 13 ~ 110 | 12.9 ~ 181 | 14.1 ~ 214.4 |
Net (Rated) Capacity kW* Cooling / Heating | 16.4 / 17.3 | 19.9 / 19.7 | 65.1 / 64.5 | 80.2 / 81.4 | 91.0 / 95.8 | 146 / 145 | 177.9 / 184.1 | 207 / 203 |
Energy Efficiency* EER / AEER * | 3.34 / 3.30 | 3.52 / 3.48 | 3.81 / 3.78 | 3.15 / 3.14 | 3.04 / 3.03 | 3.24 / 3.22 | 3.34 / 3.33 | 3.54 / 3.53 |
Energy Efficiency* COP / ACOP * | 3.42 / 3.38 | 3.67 / 3.63 | 3.91 / 3.88 | 3.24 / 3.22 | 3.03 / 3.03 | 3.22 / 3.22 | 3.33 / 3.33 | 3.53 / 3.53 |
TCSPF (cold/mixed/hot) | 5.73/5.16/5.20 | 6.23/5.42/4.97 | 6.07/5.48/5.32 | 5.18/4.67/4.51 | 4.53/4.14/4.04 | 4.78/4.33/4.21 | 5.38/4.80/4.60 | 5.32/4.81/4.49 |
HSPF (cold/mixed/hot) | 3.55/3.76/3.95 | 3.78/4.03/4.22 | 3.56/3.58/3.70 | 2.84/3.00/3.06 | 2.67/2.71/2.74 | 3.71/3.97/4.16 | 3.12/3.37/3.52 | 3.15/3.36/3.47 |
Power Supply | 3 ph. 400V ac 50Hz + N + E | |||||||
Run Amps / Phase (A/ph) | 9.0/7.5/9.0 | 10.0/8.5/11.5 | 25/28/31 | 37/39/45 | 46/41/47 | 69/67/74 | 94/81/91 | 108/101/111 |
Max Running Amps (Total System) | 14.0/10.5/13.0 | 20.0/15.5/18.0 | 50/54/59 | 55/60/66 | 74/74/77 | 116/111/121 | 132/123/132 | 158/153/159 |
Unit Controllers Master Controller | c.pCO | |||||||
Unit Controllers Slave Controller | UC8 (x1) | UC8 (x2) | UC8 (x4) | |||||
System Compressors | Inverter Scroll x 1 | Inverter Scroll x 2 | Inverter Scroll x 4 | |||||
System Number of Refrigeration Circuits | 1 | 2 | 4 | |||||
System Refrigerant | R32 | |||||||
System Ambient Op. Range (°C) Cooling / Heating | Cooling -10 to 50 / Heating -10 to 25 | |||||||
Fans Indoor | EC Forward Curved (x2) | EC Plug (x2) | EC Plug (x4) | |||||
Fans Outdoor | Variable Speed Axial Fans (x1) | Variable Speed Axial Fans (x2) | EC Axial (x4) | |||||
Airflow (l/s) Nominal** | 900 | 1050 | 3,600 | 4,300 | 4,700 | 8,100 | 8,400 | 11,000 |
Airflow (l/s) Maximum | 1000 | 1400 | 4,500 | 5,650 | 5,800 | 8,100 | 8,900 | 11,000 |
Overall Dimensions (mm) Length | 1254 | 1615 | 2938 | 2898 | 2898 | 4500 | 4500 | 5000 |
Overall Dimensions (mm) Width | 1230 | 1252 | 2121 | 2151 | 2151 | 2325 | 2305 | 2300 |
Overall Dimensions (mm) Height | 1176 | 1174 | 2291 | 2258 | 2258 | 2348 | 2650 | 2648 |
Weight (kg) Net | 247 | 299 | 1214 | 1270 | 1270 | 2064 | 2263 | 2577 |
Notes: * To AS/NZS 3823 conditions ** Supply Airflow at Nominal Conditions *** Units comply with MEPS & or the requirements on the NCC
Contact Information & Further Details
For more information, specifications, or to discuss your project needs, please visit the Temperzone website or contact your local representative.
Website: temperzone.com
Australia Sales:
- Sydney: 02-8822 5700 (nswsales@temperzone.com)
- Adelaide: 08-8115 2111 (sasales@temperzone.com)
- Brisbane: 07-3308 8333 (qldsales@temperzone.com)
- Melbourne: 03-8769 7600 (vicsales@temperzone.com)
Distributors:
- Newcastle: 02-4962 1155
- Perth: 08-6399 5900
- Launceston: 03-6331 4209
New Zealand Sales:
- Auckland: 09-279 5250 (nzsales@temperzone.com)
- Hamilton: 07-839 2705
- Wellington: 04-569 3262
- Christchurch: 03-379 3216
Asia Sales:
- Singapore: 65-6733 4292 (sales@temperzone.com.sg)
- Shanghai: 21-5648 2078
Temperzone reserves the right to change specifications without prior notice to incorporate the latest innovations. The information provided is for informative purposes only. Temperzone disclaims responsibility for any direct or indirect damage arising from the use or interpretation of the recommendations in this catalogue.
[Logo: Temperzone climate innovations]
[FSC Logo: Paper from responsible sources, FSC® C148014]