Precautions for Safety

ℹ️ Read the precautions in this manual carefully before operating the unit.

This appliance is filled with R32.

Warning indications on the air conditioner unit

Warning indication Description

CAUTION

BURST HAZARD

Open the service valves before the operation, otherwise there might be the burst.

CAUTION

BURST HAZARD

Open the service valves before the operation, otherwise there might be the burst.

DANGER

WARNING

CAUTION

CAUTION

1 Indoor Unit Display

Display brightness can be adjusted, follow procedure on page 17. w Requires Wireless LAN connecting adapter which available as accessory.

2 Preparation Before Use

Preparing Filters

  1. Open the air inlet grille and remove the air filters.
  2. Attach the filters. (see detail in the Installation Manual).

Loading Batteries (when use wireless operation)

  1. Remove the slide cover.
  2. Insert 2 new batteries (AAA type) following the (+) and (-) positions.

Clock Setup

  1. Push CLOCK by tip of the pencil. If timer indication is flashing, go to the next step.
  2. Press ON or OFF: adjust the time.
  3. Press SET: Set the time.

Remote Control Reset

Push RESET by tip of the pencil or remove batteries.

  1. Remove the batteries.
  2. Press OPERATION button.
  3. Insert the batteries.

3 Air Flow Direction

  1. Press FIX: Move the louver in the desired vertical direction.
  2. Press SWING: Swing the air automatically and press again to stop.
  3. For horizontal direction, adjust manually.

Note:

4 Remote Control

Note: The provided Remote Controller is a wireless type, which also can be used as a wire. Please see "How to Connect The Remote Controller for Wired Operation", located in installation instruction, in case of wired control is required. In wire operation, remote controller will return to initial condition (PRESET, TIMER and CLOCK will return to initial condition) when user shutdown power supply of Air conditioner.

Operation Modes

5 Cooling / Heating / Fan Only Operation

  1. Press MODE: Select Cool, Heat or Fan only.
  2. Press TEMP: Set the desired temperature. Min. 17°C, Max. 30°C. (Fan Only: No temperature indication)
  3. Press FAN: Select AUTO, LOW, LOW+, MED, MED+, HIGH or QUIET.

6 Automatic Operation

To automatically select cooling, heating or fan only operation:

  1. Press MODE: Select Auto A.
  2. Press TEMP: Set the desired temperature. Min. 17°C, Max. 30°C.
  3. Press FAN: Select AUTO, LOW, LOW+, MED, MED+, HIGH or QUIET.

7 Dry Operation

For dehumidification, a moderate cooling performance is controlled automatically.

  1. Press MODE: Select Dry.
  2. Press TEMP: Set the desired temperature. Min. 17°C, Max. 30°C.

Note: DRY mode fan speed is set to Auto only.

8 Hi Power Operation

To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY and FAN ONLY mode):

Press HI POWER: Start and stop the operation.

9 ECO Operation

To automatically control room temperature to save energy (except in DRY and FAN ONLY mode):

Press ECO: Start and stop the operation.

Note: Cooling operation: the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.

10 Fireplace and 8°C Heating Operation

Fireplace Operation

Keep indoor unit's fan blowing continuously during thermo off, to circulate heat from other sources over the room. There are three setting parameters: Default setting > Fireplace 1 > Fireplace 2.

8°C Heating Operation

Heat mode operation for keep room temperature (5-13°C) with less energy usage.

Note: While Fireplace operation on heating mode, indoor unit fan always runs and cold air breezing might be occurred. Fireplace and 8°C will operate in Heating mode only.

Advanced Operations

11 Plasma Ion

Capture efficiency of floating impurities in the air is accelerated by plasma ion. Contaminates such as bacteria, odor, smoke, dust and virus are caught and deactivated by Plasma Ion.

  1. When stopping operation: After stopping, automatic cleaning starts (TIMER lamp turns on). * When operating time is 10 minutes or less, cleaning function does not operate.
  2. When using together with the air conditioning: Air volume and direction setting of air conditioner have priority.

Operation: Operate Plasma Ion while air conditioning. Press the PURE button.

Stop: Stop both Plasma Ion and air conditioning. Press the POWER button. Stop only Plasma Ion. Press the PURE button.

Note: Plasma Ion operation does not remove harmful substances from cigarette smoke (carbon monoxide etc.). Open a window occasionally for ventilation.

12 Comfort Sleep Operation

For comfortable sleep, automatically control air flow and automatically turn OFF (Except in DRY mode).

  1. Press TIMER: Select 1, 3, 5 or 9 hrs for OFF timer operation.
  2. Press CLR to cancel the comfort sleep operation.

Note: The cooling operation, the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature will decrease.

13 HADA CARE FLOW Operation

HADA CARE FLOW: Air flow upward to the ceiling, provide indirect air flow to body and homogenize room temperature.

Press AIRFLOW for start and stop HADA CARE FLOW.

Note: During HADA CARE FLOW mode, FIX and SWING buttons cannot be activated.

14 Power-Selection and Silent Operation (Outdoor Unit)

Power-Selection (P-SEL)

This function is used when the circuit breaker is shared with other electrical appliances. It limits the maximum current and power consumption to 100%, 75%, or 50%. The lower percentage, the higher saving and also longer compressor lifetime.

Note: When the level is selected, POWER-SEL level flashes on remote LCD display for 3 seconds. In case of 75% and 50% level, number "75" or "50" also flashes for 2 seconds. Due to the reason that POWER-SELECTION function limits the maximum current, inadequate cooling or heating capacity may occur.

Silent Operation

Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime. By this feature, the heating capacity will be optimized to deliver such silent experience. The silent operation can be selected from one of two purposes (Silent 1 and Silent 2). There are three setting parameters: Standard level > Silent 1 > Silent 2.

Note: While activating of Silent operation, inadequate heating (or cooling) capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit) indicators: [100%], [75%], [50%], SILENT#1, SILENT#2

15 Timer Operation

Set the timer when the air conditioner is operating.

Setting the ON Timer

  1. Press ON: Set the desired ON timer.
  2. Press SET: Set the timer.
  3. Press CLR: Cancel the timer.

Setting the OFF Timer

  1. Press OFF: Set the desired OFF timer.
  2. Press SET: Set the timer.
  3. Press CLR: Cancel the timer.

Note: Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur. The setting will be saved for the next same operation.

16 Preset Operation

Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction).

  1. Select your preferred operation.
  2. Press and hold PRESET for 3 seconds. The P mark displays.
  3. Press PRESET: Operate the preset operation.

17 Display Lamp Brightness Adjustment

To decrease the display lamp brightness or turn it off.

  1. Press and hold FAN for 3 seconds until brightness level (d0, d1, d2 or d3) is shown on remote control LCD then release the button.
  2. Press TEMP Rise or TEMP Decrease to adjust brightness in 4 levels.
Remote control LCD Operation display Brightness
d3 Lamp illuminates full brightness. 100%
d2 Lamp illuminates 50% brightness. 50%
d1 Lamp illuminates 50% brightness and the operation lamp is turned off. 50%
d0 All lamps are turned off. All turned off

Note: In the examples of d1 and d0, the lamp illuminates for 5 seconds before going off.

18 Auto Restart Function Setting

This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.

Information: The product is shipped with Auto Restart function in the ON position. Turn it OFF if this function is not required.

How to turn OFF the Auto Restart Function: Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds but OPERATION lamp does not blink).

How to turn ON the Auto Restart Function: Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).

Note: In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate. Default setting of AUTO RESTART OPERATION is ON.

19 Self Cleaning Operation (Cool and Dry Operation Only)

To protect bad smell caused by the humidity in the indoor unit.

  1. If the SELF CLEAN button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for another 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.
  2. To stop the unit immediately, press the POWER button twice within 30 seconds.

20 Temporary Operation

In case of the misplaced or discharged remote control:

Pressing the RESET button, the unit can start or stop without using the remote control. Operation mode is set on AUTOMATIC operation, preset temperature is 24°C and fan operation is automatic speed.

21 Remote Control A-B Selection

To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly.

Remote Control B Setup

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold CHECK button on the Remote Control by the tip of the pencil. "00" will be shown on the display. (Picture 1)
  4. Press MODE during pushing CHECK. "B" will show on the display and "00" will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2)

Note:

  1. Repeat above step to reset Remote Control to be A.
  2. Remote Control A has not "A" display.
  3. Default setting of Remote Control from factory is A.

22 Operation and Performance

  1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.
  2. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.
  3. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop.
  4. Automatic defrosting: Fans will stop during defrost operation.
  5. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner.
  6. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
  7. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/contraction of plastic.

Note: Item 2 to 6 for Heating model.

Air conditioner operating conditions

Operation Temp. Outdoor Temperature Room Temperature
Heating -15°C ~ 24°C Less than 28°C
Cooling -10°C ~ 46°C 21°C ~ 32°C
Dry -10°C ~ 46°C 17°C ~ 32°C

23 Maintenance

Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

Air filters

Clean every 2 weeks.

  1. Open the air inlet grille.
  2. Remove the air filters.
  3. Vacuum or wash and then dry them.
  4. Reinstall the air filters and close the air inlet grille.

24 Troubleshooting (Check Point)

The unit does not operate.

Cooling or Heating is abnormally low.

25 Weekly Timer Operation

How to set WEEKLY TIMER

  1. Press DAY/EDIT to enter WEEKLY TIMER setting.
  2. Press DAY/EDIT to select desired day in sequence. The sequence of day symbol appears on the LCD (SU, MO, TU, WE, TH, FR, SA).
  3. Press PROGRAM to select the program number. The program 1 is ready for setting while DAY/EDIT is pressed. PG-1 appears on the LCD. Press PROGRAM to change the program number in the sequence program 1 to program 4.
  4. Press TEMP Rise or TEMP Decrease to select the desired time. The time can be set between 0:00 and 23:50 in 10 minute intervals. Press and hold the button to change setting time for 1 hr. Only one of ON or OFF timer can be set on each program.
  5. Press MODE to select desired operation.
  6. Press TEMP Rise or TEMP Decrease to select desired temperature. The temperature can be set between 17°C and 30°C.
  7. Press FAN to select the desired fan speed.
  8. Add operations, if required. Press 8°C to use 8°C operation. (Notes: Fireplace cannot select and memorize in weekly function). Press ECO to use ECO operation. Press Hi POWER to use Hi POWER operation. Press SILENT to use Silent operation.
  9. Adding or editing the program: The program can be set to perform on all the required days until SET is pressed to confirm the setting.
  10. If adding or editing a program is required, please repeat steps 2 - 8 before setting confirmation.
  11. After adding or editing, press SET to confirm the setting*.

Note: *Point remote control at air conditioner receiving module then, press SET button until you hear the "PiPi" sound. This means the setting operation has been completed. As the air conditioner is receiving the signal, you will hear separate "Pi" sounds corresponding to the number of days in the selected setting. An incomplete setting is indicated if the TIMER lamp is blinking. Press CLR twice.

Notes:

Edit Weekly timer program

To edit the program after confirming the weekly timer setting, follow steps 1 - 3 below.

  1. Press DAY/EDIT. The day of the week and the program number of the current day will be displayed.
  2. Press DAY/EDIT to select the day of the week and press PROGRAM to select program number to be confirmed.
  3. Press SET to exit confirming mode.

Deactivating WEEKLY TIMER operation

Press ON/OFF while "WEEKLY" is displayed on the LCD. The "WEEKLY" indicator will disappear from the LCD. However, the program will remain in the remote control. The TIMER lamp goes off. To reactivate the WEEKLY TIMER operation again, press ON/OFF again, LCD shows the next program. The program, after reactivation, is related to the clock time.

To delete programs

The individual program

  1. Press DAY/EDIT. The day of the week and the program number is displayed. Select the day to delete the program.
  2. Press PROGRAM to select the program number to be deleted.
  3. Press CLR. ON or OFF timer will be cleared and the LCD will blink.
  4. Press SET to delete the program. Press SET while the LCD is blinking. The program has now been deleted.

All programs

  1. Press DAY/EDIT. The day of the week and the program number will be displayed.
  2. Press CLR and hold for 3 seconds. All programs will be deleted and LCD displays current operation.

Notes: Make sure the remote control receiving module on the air conditioner receives the signal from the remote control.

Models: RAS-07 Air Conditioner, RAS-07, Air Conditioner, Conditioner

File Info : application/pdf, 12 Pages, 1.52MB

PDF preview unavailable. Download the PDF instead.

300 Acrobat Distiller 19.0 (Macintosh)

Related Documents

Preview Toshiba Air Conditioner Owner's Manual
Owner's manual for Toshiba split-type air conditioners, covering safety precautions, operation, maintenance, and troubleshooting for models RAS-07, 10, 13, 16, 18E2KV2G-A (indoor) and RAS-07, 10, 13, 16, 18E2AVG-A (outdoor).
Preview Toshiba R32 Inverter Air Conditioner Owner's Manual
Comprehensive owner's manual for Toshiba R32 Inverter Air Conditioners, covering safety precautions, remote control operation, various modes (Cooling, Heating, Fan, Dry, Hi Power, ECO, Comfort Sleep), power selection, timer functions, and maintenance for indoor units RAS-30, 34, 36E2KVG-A and outdoor units RAS-30, 34, 36E2AVG-A.
Preview Toshiba Air Conditioner Owner's Manual
Owner's manual for Toshiba split type air conditioners, covering operation, maintenance, and troubleshooting for R32 and R410A inverter models.
Preview Toshiba Ilmastointilaitteen Käyttöopas
Tämä on Toshiban split-tyyppisten ilmastointilaitteiden käyttöopas, joka sisältää turvallisuusohjeet, käytön, tilat, huollon ja vianmäärityksen.
Preview Toshiba SHORAI Edge Black & White R32 Inverter Heat Pump Air Conditioner
Explore the new Toshiba SHORAI Edge Black & White R32 inverter heat pump air conditioner, offering high efficiency (SEER/SCOP A+++), advanced features, and Wi-Fi connectivity for residential applications. View detailed model names and technical specifications.
Preview TOSHIBA V-DRシリーズ エアコン カタログ | 省エネ・プラズマ空清・無風感空調
東芝のV-DRシリーズエアコンのカタログ。省エネ性能、プラズマ空清による空気清浄機能、無風感空調による快適な気流、お手入れのしやすさなど、製品の特長と仕様を詳しく紹介しています。
Preview Toshiba Luftkonditionering Användarmanual - Drift och Underhåll
Omfattande användarmanual för Toshiba split-typ luftkonditioneringsenheter (R32/R410A Inverter). Täcker installation, drift, säkerhetsföreskrifter, felsökning och underhåll. Inkluderar modellnummer RAS-B05, 07, 10, 13, 16E2KVG-E, RAS-18, 24E2KVG-E, RAS-05, 07, 10, 13, 16, 18, 24E2AVG-E.
Preview Toshiba SHORAI EDGE Air Conditioner: Advanced Design, Energy Efficiency, and Smart Comfort
Discover the Toshiba SHORAI EDGE air conditioner, featuring a sleek design, A+++ energy efficiency, quiet operation, HADA CARE technology for well-being, and smart app control for ultimate home comfort.