TOSHIBA OWNER'S MANUAL
R32 or R410A INVERTER
ENGLISH
Indoor Unit Display
- ECO (White)
- Wi-Fi access (White) *
- Hi POWER (White)
- Timer (White)
- Operation mode (White)
* Display brightness can be adjusted, follow procedure on page 14.
* Require Wireless LAN connecting adapter which available as accessory.
Preparation Before Use
Preparing Filters
- Open the air inlet grille and remove the air filters.
- Attach the filters. (see detail in the Installation Manual).
Loading Batteries (when use wireless operation.)
- Remove the slide cover.
- Insert 2 new batteries (AAA type) following the (+) and (-) positions.
Clock Setup
- Push CLOCK by tip of the pencil. If timer indication is flashing, go to the next step 2.
- Press ON or OFF: adjust the time.
- Press SET: Set the time.
Remote Control Reset
Push RESET by tip of the pencil or
- Remove the batteries.
- Press RESET.
- Insert the batteries.
Air Flow Direction
- Press FIX: Move the louver in the desired vertical direction.
- Press SWING: Swing the air automatically and press again to stop.
For horizontal direction, adjust manually.
Note:
- Do not move the louver manually by others.
- The louver may automation positioning by some operation mode.
Remote Control
Infrared signal emitter
- Start/Stop button
- Mode select button (MODE)
- Temperature button (TEMP)
- Fan speed button (FAN)
- Swing louver button (SWING)
- Set louver button (FIX)
- 8°C Heating Operation (8°C)
- On timer button (ON)
- Off timer button (OFF)
- Setup button (SET)
- Clear button (CLR)
- Memory and Preset button (PRESET)
- Silent operation button (SILENT)
- High power button (Hi POWER)
- Eco button (ECO)
- Quiet button (QUIET)
- Comfort sleep button (COMFORT SLEEP)
- Filter reset button (FILTER)
- Set clock button (CLOCK)
- Check button (CHECK)
- Reset button (RESET)
Note:
- The provided Remote Controller is a wireless type, which also can be used as a wire. Please see "How to Connect The Remote Controller for Wired Operation", located in installation instruction, in case of wired control is required.
- In wire operation, remote controller will return to initial condition (PRESET, TIMER and CLOCK will return to initial condition) when user shutdown power supply of Air conditioner.
Silent Operation
Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime. By this feature, the heating capacity will be optimized to deliver such silent experience. The silent operation can be selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to ensure having sufficient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any circumstance where the outdoor unit's sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit by 4 dB(A).
Note:
- While activating of Silent operation, inadequate heating (or cooling) capacity may occur.
Silent Operation (Outdoor Unit)
Press SILENT#1, SILENT#2, None
Automatic Operation
To automatically select cooling, heating or fan only operation
- Press MODE: Select Auto A.
- Press TEMP.: Set the desired temperature. Min. 17°C, Max. 30°C.
- Press FAN: Select AUTO, LOW, LOW+, MED ---, MED+ or HIGH ----
Cooling / Heating / Fan Only Operation
- Press MODE: Select Cool Heat or Fan only
- Press TEMP.: Set the desired temperature. Min. 17°C, Max. 30°C.
- Press FAN: Select AUTO, LOW, LOW+, MED ---, MED+ or HIGH ----
Dry Operation
For dehumidification, a moderate cooling performance is controlled automatically.
- Press MODE: Select Dry
- Press TEMP.: Set the desired temperature. Min. 17°C, Max. 30°C.
Note: Dry mode fan speed is set to Auto only.
Hi Power Operation
To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY and FAN ONLY mode)
- Press HI POWER: Start and stop the operation.
Eco Operation
To automatically control room temperature to save energy (except in DRY and FAN ONLY mode)
- Press ECO: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.
8°C Operation
- Press 8°C button to change to 8°C set temperature heating operation.
- Press TEMP. to adjust setting temperature from 5°C to 13°C.
Note: 8°C will operate in Heating mode only. If Air conditioner performs in cooling operation (including automatic cooling) or dry operation it will change to heating operating.
Temporary Operation
In case of the misplaced or discharged remote control
- Pressing the RESET button, the unit can start or stop without using the remote control.
- Operation mode is set on AUTOMATIC operation, preset temperature is 24°C and fan operation is automatic speed.
OPERATION / RESET Button
Timer Operation
Set the timer when the air conditioner is operating.
Setting the ON Timer
- Press ON: Set the desired ON timer.
- Press SET: Set the timer.
- Press CLR: Cancel the timer.
Setting the OFF Timer
- Press OFF: Set the desired OFF timer.
- Press SET: Set the timer.
- Press CLR: Cancel the timer.
Daily Timer
Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis.
- Press ON: Set the ON timer.
- Press OFF: Set the OFF timer.
- Press SET button during the (ON) or (OFF) mark flashing.
Note:
- Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur.
- The setting will be saved for the next same operation.
Display Lamp Brightness Adjustment
To decrease the display lamp brightness or turn it off.
- Press and hold FAN for 3 seconds until brightness level (d0, d1, d2 or d3) is shown on remote control LCD then release the button.
- Press TEMP. Rise or TEMP. Decrease to adjust brightness in 4 levels.
Brightness
Remote control LCD | Operation display | Brightness |
d3 | Lamp illuminates full brightness. | 100% |
d2 | Lamp illuminates 50% brightness. | 50% |
d1 | Lamp illuminates 50% brightness and the operation lamp is turned off. | 50% |
d0 | All lamps are turned off. | All lamps are turned off. |
Note: In the examples of d1 and d0, the lamp illuminates for 5 seconds before going off.
Preset Operation
Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction).
- Select your preferred operation.
- Press and hold PRESET for 3 seconds to memorize the setting. The mark displays.
- Press PRESET: Operate the preset operation.
Auto Restart Function Setting
This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position. Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note:
- In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate.
Quiet Operation
To operate at super low fan speed for quiet operation (except in DRY mode)
- Press QUIET: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate cooling due to low sound features.
Comfort Sleep Operation
For comfortable sleep, automatically control air flow and automatically turn OFF.
- Press COMFORT SLEEP: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature will decrease.
Maintenance
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
- Clean the indoor unit and the remote control with a wet cloth when needed.
- No benzine, thinner, polishing powder or chemically-treated duster.
Air filters
Clean every 2 weeks.
- Open the air inlet grille.
- Remove the air filters.
- Vacuum or wash and then dry them.
- Reinstall the air filters and close the air inlet grille.
Self Cleaning Operation (Cool and Dry Operation Only)
To protect bad smell caused by the humidity in the indoor unit.
- If the SELF CLEAN button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for other 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.
- To stop the unit immediately, press the SELF CLEAN button more than 2 times within 30 seconds.
Manual Defrost Operation
To defrosting the heat exchanger of the outdoor unit during Heating operation.
Press and hold SET for 5 sec. then remote control display will show [dF] as picture for 2 sec.
Operation and Performance
- Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.
- Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.
- Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop.
- Automatic defrosting: Fans will stop during defrost operation.
- Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner.
- Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
- Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Operation | Outdoor Temperature | Room Temperature |
Heating | -15°C~24°C | Less than 28°C |
Cooling | -15°C~46°C | 21°C~32°C |
Dry | -15°C~46°C | 17°C~32°C |
Troubleshooting (Check Point)
The unit does not operate.
- The power main switch is turned off.
- The circuit breaker is activated to cut off the power supply.
- Stoppage of electric current
- ON timer is set.
Cooling or Heating is abnormally low.
- The filters are blocked with dust.
- The temperature has been set improperly.
- The windows or doors are opened.
- The air inlet or outlet of the outdoor unit is blocked.
- The fan speed is too low.
- The operation mode is FAN or DRY
- POWER SELECTION function is set 75% or 50% (This function is depend on remote controller).
Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
- Press RESET button on the indoor unit to turn the air conditioner ON.
- Point the remote control at the indoor unit.
- Push and hold CHECK button on the Remote Control by the tip of the pencil. "00" will be shown on the display. (Picture 1)
- Press MODE during pushing CHECK. "B" will show on the display and "00" will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2)
Note:
- Repeat above step to reset Remote Control to be A.
- Remote Control A has not "A" display.
- Default setting of Remote Control from factory is A.
File Info : application/pdf, 5 Pages, 761.46KB
DocumentDocumentReferences
Acrobat Distiller 21.0 (Macintosh)Related Documents
![]() |
Toshiba Luftkonditionering Användarmanual - Drift och Underhåll Omfattande användarmanual för Toshiba split-typ luftkonditioneringsenheter (R32/R410A Inverter). Täcker installation, drift, säkerhetsföreskrifter, felsökning och underhåll. Inkluderar modellnummer RAS-B05, 07, 10, 13, 16E2KVG-E, RAS-18, 24E2KVG-E, RAS-05, 07, 10, 13, 16, 18, 24E2AVG-E. |
![]() |
Toshiba Air Conditioners Price List Price list for Toshiba air conditioners, including models like Haori NEW, Edge NEW White, YUKAI, and Bi Flow. Features cooling and heating capacities and prices in BGN/EUR. |
![]() |
Toshiba Air Conditioners Price List | Haori, Edge, Yukai, Bi Flow Models Explore the latest prices for Toshiba's range of air conditioners, including Haori NEW, Edge NEW White, YUKAI, and Bi Flow series. Featuring advanced purification and improved indoor climate control. |
![]() |
Toshiba Air Conditioner Installation Manual Comprehensive installation manual for Toshiba split-type air conditioners, covering indoor and outdoor unit setup, electrical connections, piping, and testing. |
![]() |
Toshiba Air Conditioner Manual User manual for Toshiba air conditioners, covering operation, settings, troubleshooting, and the Toshiba Home AC Control app. |
![]() |
TOSHIBA V-DRシリーズ エアコン カタログ | 省エネ・プラズマ空清・無風感空調 東芝のV-DRシリーズエアコンのカタログ。省エネ性能、プラズマ空清による空気清浄機能、無風感空調による快適な気流、お手入れのしやすさなど、製品の特長と仕様を詳しく紹介しています。 |
![]() |
Toshiba Air Conditioner Installation and Owner's Manual (R32 Inverter) Comprehensive guide for installing and operating Toshiba R32 Inverter split-type air conditioners. Covers unit setup, piping, electrical connections, operation modes, maintenance, and troubleshooting. |
![]() |
Toshiba Air Conditioner Specifications and Pricing Detailed specifications and pricing for various Toshiba air conditioner models including DAISEIKAI SUPER 9, MAORI R32, SHORAI EDGE R32, and SEIYA R32 series. Includes cooling and heating power, energy efficiency ratings (SEER, SCOP), and prices in Bulgarian Leva. |