PRECAUTIONS FOR SAFETY

Read the precautions in this manual carefully before operating the unit. ? This appliance is filled with R32.

DANGER

WARNING

CAUTION

OPERATING THE AIR CONDITIONER

1. INDOOR UNIT DISPLAY

Display brightness can be adjusted, follow procedure on 12. Requires Wireless LAN connecting adapter which available as accessory.

2. PREPARATION BEFORE USE

Preparing Filters

  1. Open the air inlet grille and remove the air filters.
  2. Attach the filters. (see detail in the Installation Manual).

Loading Batteries (when use wireless operation.)

  1. Remove the slide cover.
  2. Insert 2 new batteries (AAA type) following the (+) and (-) positions.

Clock Setup

  1. Push CLOCK by tip of the pencil. If timer indication is flashing, go to the next step 2.
  2. Press ON or OFF: adjust the time.
  3. Press SET: Set the time.

Remote Control Reset

Push RESET by tip of the pencil or

  1. Remove the batteries.
  2. Press
  3. Insert the batteries.

3. AIR FLOW DIRECTION

Note: Do not move the louver manually by hands or others. The louver may automation positioning by some operation mode.

4. REMOTE CONTROL

Infrared signal emitter

Note: The provided Remote Controller is a wireless type, which also can be used as a wire. Please see "How to Connect The Remote Controller for Wired Operation", located in installation instruction, in case of wired control is required. In wire operation, remote controller will return to initial condition (PRESET, TIMER and CLOCK will return to initial condition) when user shutdown power supply of Air conditioner.

5. ONE-TOUCH

Press the "ONE-TOUCH" button for fully automated operation that is customized to the typical consumer preferences in your region of the world. The customized settings control temperature air flow strength, air flow direction and other settings to provide you alternate contact with "ONE-TOUCH" of the button. If you prefer other settings you can select from the many other operating functions of your Toshiba unit.

Press ONE-TOUCH: Start the operation.

6. AUTOMATIC OPERATION

To automatically select cooling or heating operation

  1. Press MODE: Select Auto.
  2. Press TEMP. +/-: Set the desired temperature, Min. 17°C, Max. 30°C.
  3. Press FAN: Select AUTO, LOW, LOW+, MED ---, MED+ or HIGH.

7. COOLING / HEATING OPERATION

  1. Press MODE: Select Cool or Heat.
  2. Press TEMP. +/-: Set the desired temperature, Min. 17°C, Max. 30°C.
  3. Press FAN: Select AUTO, LOW, LOW+, MED ---, MED+ or HIGH.

8. DRY OPERATION

For dehumidification, a moderate cooling performance is controlled automatically.

  1. Press MODE: Select Dry.
  2. Press TEMP. +/-: Set the desired temperature, Min. 17°C, Max. 30°C.

Note: Dry mode fan speed is set to Auto only.

9. HI POWER OPERATION

To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY mode)

Press HI POWER: Start and stop the operation.

10. ECO OPERATION

To automatically control room temperature to save energy (except in DRY mode)

Press ECO: Start and stop the operation.

Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.

11. TIMER OPERATION

Set the timer when the air conditioner is operating.

Setting the ON Timer

  1. Press ON TIMER: Set the desired ON timer.
  2. Press SET: Set the timer.
  3. Press CLR: Cancel the timer.

Setting the OFF Timer

  1. Press OFF TIMER: Set the desired OFF timer.
  2. Press SET: Set the timer.
  3. Press CLR: Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis.

Setting Daily Timer

  1. Press ON TIMER: Set the ON timer.
  2. Press OFF TIMER: Set the OFF timer.
  3. Press SET button during the (or) mark flashing.

Note: Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur. The setting will be saved for the next same operation.

12. DISPLAY LAMP BRIGHTNESS ADJUSTMENT

To decrease the display lamp brightness or turn it off.

  1. Press and hold FAN for 3 seconds until brightness level (d0, d1, d2 or d3) is shown on remote control LCD then release the button.
  2. Press TEMP. Rise or TEMP. Decrease to adjust brightness in 4 levels.
Remote control LCD Operation display Brightness
d3 Lamp illuminates full brightness. 100%
d2 Lamp illuminates 50% brightness. 50%
d1 Lamp illuminates 50% brightness and the operation lamp is turned off. 50%
d0 All lamps are turned off. All turned off

Note: In the examples of d1 and d0, the lamp illuminates for 5 seconds before going off.

13. TEMPORARY OPERATION

In case of the misplaced or discharged remote control

14. PRESET OPERATION

Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction).

  1. Select your preferred operation.
  2. Press and hold PRESET for 3 seconds to memorize the setting. The mark displays.
  3. Press PRESET: Operate the preset operation.

15. AUTO RESTART FUNCTION SETTING

This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.

Information: The product is shipped with Auto Restart function in the ON position. Turn it OFF if this function is not required.

How to turn OFF the Auto Restart Function

Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds but OPERATION lamp does not blink).

How to turn ON the Auto Restart Function

Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).

Note: In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate. Default setting of AUTO RESTART OPERATION is ON.

16. QUIET OPERATION

To operate at super low fan speed for quiet operation (except in DRY mode)

Press QUIET: Start and stop the operation.

Note: Under certain conditions, QUIET operation may not provide adequate cooling due to low sound features.

17. COMFORT SLEEP OPERATION

For comfortable sleep, automatically control air flow and automatically turn OFF.

Press COMFORT SLEEP: Select 1, 3, 5 or 9 hrs for OFF timer operation.

Note: 1. The cooling operation, the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature will decrease. 2. Both of Eco and Timer lamp illuminates.

18. SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)

To protect bad smell caused by the humidity in the indoor unit.

  1. If the button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for other 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.
  2. To stop the unit immediately, press the button more than 2 times within 30 seconds.

MAINTENANCE

Firstly, turn off the circuit breaker. ⚠️

Indoor Unit and Remote Control

Air filters

Clean every 2 weeks.

  1. Open the air inlet grille.
  2. Remove the air filters.
  3. Vacuum or wash and then dry them.
  4. Reinstall the air filters and close the air inlet grille.

OPERATION AND PERFORMANCE

  1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.
  2. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.
  3. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop.
  4. Automatic defrosting: Fans will stop during defrost operation.
  5. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner.
  6. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
  7. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/contraction of plastic.

Note: Item 2 to 6 for Heating model

Air conditioner operating conditions

Operation Outdoor Temperature Room Temperature
Heating -15°C~24°C 0°C~28°C
Cooling -10°C~46°C 21°C~32°C
Dry -10°C~46°C 17°C ~ 32°C

TROUBLESHOOTING (CHECK POINT)

The unit does not operate.

Cooling or Heating is abnormally low.

REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold CHECK button on the Remote Control by the tip of the pencil. "00" will be shown on the display. (Picture 1)
  4. Press MODE during pushing CHECK. "B" will show on the display and "00" will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2)

Note: 1. Repeat above step to reset Remote Control to be A. 2. Remote Control A has not "A" display. 3. Default setting of Remote Control from factory is A.

Models: R32 Air Conditioner, R32, Air Conditioner, Conditioner

File Info : application/pdf, 8 Pages, 1.17MB

PDF preview unavailable. Download the PDF instead.

RAS-13E2KV2G-A-IDUC-Toshiba-User-Manual Acrobat Distiller 21.0 (Macintosh)

Related Documents

Preview Toshiba R32 Inverter Air Conditioner Owner's Manual
Comprehensive owner's manual for Toshiba R32 Inverter split type air conditioners, covering operation, safety precautions, maintenance, and troubleshooting for models RAS-07/10/13/16E2KVSG-A and RAS-07/10/13/16E2AVSG-A.
Preview Toshiba Air Conditioners Price List
Price list for Toshiba air conditioners, including models like Haori NEW, Edge NEW White, YUKAI, and Bi Flow. Features cooling and heating capacities and prices in BGN/EUR.
Preview Toshiba R32 Inverter Air Conditioner Owner's Manual
Comprehensive owner's manual for Toshiba R32 Inverter Air Conditioners, covering safety precautions, remote control operation, various modes (Cooling, Heating, Fan, Dry, Hi Power, ECO, Comfort Sleep), power selection, timer functions, and maintenance for indoor units RAS-30, 34, 36E2KVG-A and outdoor units RAS-30, 34, 36E2AVG-A.
Preview Toshiba Air Conditioners Price List | Haori, Edge, Yukai, Bi Flow Models
Explore the latest prices for Toshiba's range of air conditioners, including Haori NEW, Edge NEW White, YUKAI, and Bi Flow series. Featuring advanced purification and improved indoor climate control.
Preview TOSHIBA V-DRシリーズ エアコン カタログ | 省エネ・プラズマ空清・無風感空調
東芝のV-DRシリーズエアコンのカタログ。省エネ性能、プラズマ空清による空気清浄機能、無風感空調による快適な気流、お手入れのしやすさなど、製品の特長と仕様を詳しく紹介しています。
Preview Toshiba Luftkonditionering Användarmanual - Drift och Underhåll
Omfattande användarmanual för Toshiba split-typ luftkonditioneringsenheter (R32/R410A Inverter). Täcker installation, drift, säkerhetsföreskrifter, felsökning och underhåll. Inkluderar modellnummer RAS-B05, 07, 10, 13, 16E2KVG-E, RAS-18, 24E2KVG-E, RAS-05, 07, 10, 13, 16, 18, 24E2AVG-E.
Preview Toshiba SHORAI Edge Black & White R32 Inverter Heat Pump Air Conditioner
Explore the new Toshiba SHORAI Edge Black & White R32 inverter heat pump air conditioner, offering high efficiency (SEER/SCOP A+++), advanced features, and Wi-Fi connectivity for residential applications. View detailed model names and technical specifications.
Preview Toshiba Ilmastointilaitteen Käyttöopas
Tämä on Toshiban split-tyyppisten ilmastointilaitteiden käyttöopas, joka sisältää turvallisuusohjeet, käytön, tilat, huollon ja vianmäärityksen.