SOMMER 7023 Photo Eye (2-Wire)
Model: 7023
Manufacturer: SOMMER Antriebs- und Funktechnik GmbH
Technical Data
Parameter | Value |
---|---|
Range | 8 m |
Temperature Range | -20° C ... 60° C |
Bus Voltage Range | 20 V ... 30 V |
Current Consumption | max. 20 mA |
IP Protection Class | IP 44 |
Installation Instructions
This section provides step-by-step instructions for mounting the SOMMER 7023 Photo Eye (2-wire).
- Step 1: Preparation
Begin installation. The ? symbol indicates the start. Maximum recommended distance between transmitter (TX) and receiver (RX) units is 10 meters.
- Step 2: Mounting Bracket Placement
Position mounting brackets (labeled A and B for TX and RX respectively). Ensure a minimum clearance of 25mm from any surface. The total cable length should not exceed 10 meters.
- Step 3: Mount Transmitter (TX)
Attach the TX unit to its designated mounting point. The diagram shows a measurement of 225mm from a reference point.
- Step 4: Mount Receiver (RX)
Attach the RX unit to its designated mounting point. The diagram shows a measurement of 225mm from a reference point.
- Step 5: Secure Units to Brackets
Attach the TX and RX units securely to their respective mounting brackets.
- Step 6: Connect Cables to TX
Connect the wiring to the TX unit. The diagram shows two wires being connected.
- Step 7: Connect Cables to RX
Connect the wiring to the RX unit. The diagram shows two wires being connected.
- Step 8: Align TX and RX Units
Align the TX and RX units. The diagram shows them positioned opposite each other.
- Step 9: Confirmation of Alignment
Confirm successful alignment. The 'click' symbol indicates successful alignment or connection.
- Step 10: Transmitter Unit Dimensions
The transmitter unit has dimensions of approximately 50mm width and 36mm height.
- Step 11: Receiver Unit Dimensions
The receiver unit has dimensions of approximately 50mm width and 36mm height.
- Step 12: Final Unit Placement
The TX and RX units are shown in their final mounted positions.
- Step 13: Connect to Control Unit
Connect the 2-wire system cables from the TX and RX units to the control unit. The diagram shows a TX+RX connection point.
- Step 14: Final Mounted Dimensions
The final installed dimensions of the system are indicated as approximately 185mm and 159mm.
Electrical Connection
The electrical connection diagram illustrates the 2-wire photo eye system (TX and RX) connecting to a control unit. The control unit has terminals labeled COM, SIGNAL, GND, and 24 V. The TX and RX units are shown as a pair, linked to the control unit's input.
Further connection instructions can be found at: som4.me/connect7023
Contact Information
SOMMER Antriebs- und Funktechnik GmbH
Hans-Böckler-Straße 21-27
73230 Kirchheim/Teck
Germany
Phone: +49 (0) 900 1800-150