SKVER LED R MF Installation Instructions
Brand: LENA LIGHTING
Model: SKVER LED R MF
Product Type: LED Luminaire
General Information & Safety
Assembly should be carried out by a qualified person.
Cleaning: Dirt that settles on the diffuser due to normal operation should be cleaned with a damp cloth. Do not use abrasive cleaners.
Disposal Information: This product is marked in accordance with European Directive 2002/96/CE and Polish Act on used electric and electronic equipment with a symbol of a crossed-out waste container. This mark indicates that the device, after its application use, cannot be placed together with other types of household waste. The user is obliged to return it to entities conducting the collection of used electric and electronic equipment. Proper proceeding with used electric and electronic equipment contributes to avoiding damaging consequences for health and the environment.
Important Note: If the external flexible cord is damaged, it should only be replaced by the manufacturer or its service agent, or a similarly qualified person, to avoid risk.
Protection Class II: This product in protection class II cannot be used with non-metallic poles. When using a metal pole, it is necessary to ground it.
Dimensions and Components
Overall Dimensions:
- Height: 184 mm
- Diameter: 360 mm
- Mounting Hole Diameter: 42 mm
- Weight: 6 kg
Included Accessories (Index 449017):
- Drill template
Fasteners:
- M6 x 10
- M6 x 20
Installation Steps
Step 1: Power Off
Ensure the power is turned off before beginning installation.
Step 2: Mounting Preparation
The luminaire is designed for mounting on poles with a standard diameter of 42 mm.
Step 3: Luminaire Attachment
Attach the luminaire to the pole. The correct position of the holder mounted to the lamp cable is crucial. Ensure a minimum IP66 rated junction box or socket is used for the cable connection.
Step 4: Electrical Connection
Connect the cables. The installation cable should be 2x1.5mm² with a diameter of Ø7-12 mm. The cable length should be at least 100 mm.
- Blue wire (N) connects to N
- Brown wire (L) connects to L
Step 5: Adjustment
Adjust the luminaire as needed. The diagram shows adjustment points marked as 'REGULACJA ADJUSTMENT'. Maximum adjustment is indicated.
Step 6: Power On
Once installation is complete and all connections are secure, turn the power back on.
Technical Specifications
- Voltage: 220-240 V
- Frequency: 50/60 Hz
- Ingress Protection: IP66