R. STAHL 8530/1-MCB-STA102-B10-000-2 Line Protection Circuit Breaker
Article No.: 293915
Product Description
The R. STAHL 8530/1-MCB-STA102-B10-000-2 line protection circuit breakers offer excellent current limitation for short circuits and high switching capacities of 10, 15, or 25 kA. This ensures minimal load on lines and high selectivity with upstream fuses. The components are modularly designed and available in 1 to 4-pole versions for nominal currents from 0.5–63 A. The maximum installation capacity is 4.5 installation units (UP).
Key Features:
- Disconnecting function according to EN 60947-2
- Energy limitation class 3
- Easy replacement or extension of systems due to modular design
- Simple plug-in mounting on a DIN rail in Ex e enclosures
- Fixed thermal-magnetic releases
- Ergonomic lever for safe operation and shutdown
- Padlock protection (accessories) prevents re-operation during maintenance
Technical Characteristics
Explosion Protection
Application Area (Zones) | 1, 2 |
---|---|
Application Area (Zones) Note | Usable in Zone 21 / 22 with protection via Ex tb / tc enclosure |
IECEx Certificate Gas | IECEX FMG 19.0029U |
IECEx Gas Explosion Protection | Ex db eb IIC Gb |
ATEX Certificate Gas | FM19ATEX0191U |
ATEX Gas Explosion Protection | II 2 G Ex db eb IIC Gb |
Certificates | ATEX (FM), Brazil (ULB), China (CQST), IECEx (FM) |
Certificate of Conformity | Certificate of Conformity (ATEX) |
Electrical Characteristics
Rated operational voltage AC | 230/400 V |
---|---|
Rated service current | 10 A |
Frequency | 50/60 Hz |
Rated service breaking capacity | 10 kA |
Electrical service life | 2 x 10⁴ |
Mechanical service life | 2 x 10⁴ |
1st auxiliary function | None |
Voltage 1st auxiliary function AC | - |
Max. current 1st auxiliary function | - |
2nd auxiliary function | None |
Max. voltage 2nd auxiliary function DC | - |
Tripping characteristic | B |
Number of poles | 2 poles |
Ambient Conditions
Ambient temperature | -40 °C ... 70 °C |
---|---|
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 158 °F |
Ambient temperature | -40°F ... +158°F |
Ambient temperature Note | Different ambient temperatures based on current certificates, on request |
Mechanical Characteristics
Degree of protection (IP) (IEC 60529) | IP2X |
---|---|
Housing material | Thermoplastic |
Connection terminal cross-section minimum | 1.5 mm² |
Connection terminal cross-section maximum | 25 mm² |
Connection terminal AWG section min. | 16 AWG |
Connection terminal AWG section max. | 4 AWG |
Connection terminal 2 cross-section min. | 1.5 mm² |
Connection terminal 2 cross-section max. | 10 mm² |
Connection terminal 2 AWG section min. | 16 AWG |
Connection terminal 2 AWG section max. | 8 AWG |
Tightening torque min. | 2 N·m |
Tightening torque max. | 3 N·m |
Connection terminal Note | Connection of 2 conductors (upper and lower chamber simultaneously): Upper and lower chamber max. 16 / 10 mm² (Connection can be made with a maximum cross-section difference between the upper and lower chamber.) |
Allowed combination possibilities | Allowed combination possibilities for connection cross-sections are indicated in the operating manual. |
Dimensions and Installation
Width | 65 mm (2.56 in) |
---|---|
Length | 165 mm (6.5 in) |
Mounting depth | 138.3 mm (5.44 in) |
Weight | 1 kg (2.205 lb) |
Mounting / Installation | |
Tightening torque | 2–3 N·m |
Tightening torque in lbf in | 17.7 ... 26.6 lbf·in |
Auxiliary contact tightening torque | 0.4–0.6 N·m |
Auxiliary contact tightening torque lbf in | 3.5 ... 5.3 lbf·in |
Technical Drawings
Diagram 1: Tripping Characteristic Curve
This diagram illustrates the tripping characteristic curve for the circuit breaker, showing the relationship between multiples of the rated current (I/In) and tripping time in seconds and minutes. It includes curves for AC and DC, with a specific mention of tripping characteristic B.
Diagram 2: Overall Dimensions
This diagram provides the overall dimensions of the circuit breaker in millimeters (with inches in parentheses). It shows the width, height, and depth, indicating it occupies 2 division units.
Accessories
Accessory | Description | Article No. |
---|---|---|
Quadruple locking device | A locking/unlocking system that allows individual locking of the component using up to 4 cylinder locks. | 227232 |
Fixing Kit | A fixing kit for attaching the component to the mounting plate without a DIN rail. | 276618 |
Cylinder Lock | For locking (shackle Ø 3) | 107115 |