Lithonia Lighting LBL8 LED Wraparound
Product Overview
The Lithonia Lighting LBL8 LED wraparound fixture provides a digital lighting platform for general ambient lighting in surface-mount applications. It features a long-life LED system with excellent color rendering for a quality, low-maintenance installation. The fixture is designed for durability and ease of maintenance.
Features & Specifications
- Intended Use: General ambient lighting for surface-mount applications.
- LED System: Delivers long life and excellent color, ensuring quality and low maintenance.
- Construction: Die-formed, pre-painted code-gauge steel housing. 100% acrylic prismatic diffuser with sonically welded luminous ends. Continuous side flanges for light trap and diffuser support.
- Optics: Curved prismatic diffuser with linear side prisms and a highly transmissive overlay to minimize lamp image and provide high-angle brightness control. Luminous end plates enhance aesthetics.
- Electrical: Long-life LEDs with high-efficiency drivers. 70% LED lumen maintenance at >60,000 hours (L70/>60,000). LEDs have a CRI of 80.
- Dimming Options: eldoLED drivers offer choice of dimming range and control. Step-level dimming option allows switching to 50% power for energy code compliance.
- Controls: Optional nLight® embedded controls for system monitoring, constant lumen management, and plug-and-play network upgrades via Cat-5 cable. Ballast disconnect provided where required.
- Installation: Intended for surface or suspend mounting.
- Listings: CSA certified (U.S. and Canadian standards), Damp listed. DesignLights Consortium® (DLC) qualified product (check QPL for specific versions).
- Government Procurement: BAA option qualifies as a domestic end product. BABA option qualifies as produced in the United States. Refer to acuitybrands.com/buy-american for details.
- Warranty: 5-year limited warranty.
- Notes: Actual performance may vary based on end-user environment and application. Values are design or typical, measured at 25 °C. Specifications subject to change.
Dimensions
Specification | Value (Inches) | Value (Centimeters) |
---|---|---|
Length | 96 | 244.0 |
Width | 10 | 25.4 |
Depth | 2-3/4 | 7.0 |
Weight | 20.25 lbs |
All dimensions are inches (centimeters) unless otherwise indicated.
.875 K.O. (6X) Knockout size
.687 K.O. (4X) Knockout size
.25X.50 SLOT (4X) Slot size
A+ Capable Luminaire
This luminaire is A+ capable, designed and tested for consistent color appearance and out-of-the-box control compatibility. It meets Acuity Brands' specification for chromatic consistency. It is part of an A+ Certified solution for nLight® control networks when ordered with specific drivers. For more information, visit www.acuitybrands.com/aplus.
Ordering Information
Lead times vary depending on options selected. Consult your sales representative.
Example: LBL8 9600LM 80CRI 35K MIN10 GZT MVOLT
Series | Lumens | CRI | Color Temperature | Minimum Dimming Level | Dimming | Voltage |
---|---|---|---|---|---|---|
LBL8 8' LED wrap | 6000LM (6000 lumens) | 80CRI (80 CRI) | 30K (3000 K) | MIN10 (Dims to 10%) | (blank) (None) | MVOLT (120-277V) |
9600LM (9600 lumens) | 35K (3500 K) | |||||
14400LM (14400 lumens) | 40K (4000 K) | |||||
50K (5000 K) | GZT (Generic 0-10V Dimming) | 347 (347V) | ||||
MIN1 (Dims to 1%) | ZT (eldoLED 0-10V dimming) |
Step-level Dimming Option
- SLD: Step-level dimming
Emergency Options
- E10WLCP: EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20 MAEDBS.
- EMG: For use with nLight on generator supply EM power.
Control Input/Lumen Management Options
- NLIGHT: nLight enabled
- CL80 NLIGHT: nLight enabled, constant lumen output, 80%
Other Options
- BAA: Buy America(n) Act and/or Build America Buy America Qualified
- BDP: Factory Installed Ballast Disconnect Plug
Option Value Ordering Restrictions
Option Value | Restriction |
---|---|
347 | Not available with SLD option. Not available with emergency battery option E10WCLP. |
6000LM | Approximate lumen output. |
9600LM | Approximate lumen output. |
14400LM | Approximate lumen output. Not available with emergency battery option E10WLCP. |
(blank) (Dimming) | When Control Input/ Lumen Management option specified, leave Dimming section blank. |
CL80 NLIGHT | When Control Input/ Lumen Management option specified, leave Dimming section blank. |
E10WLCP | Not available with 14400LM option. Not available with 347V. |
EMG | Requires nLight control option. EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture. |
MIN1 | Requires ZT or NLIGHT control option. |
MIN10 | Requires GZT control option. |
NLIGHT | When Control Input/ Lumen Management option specified, leave Dimming section blank. |
SLD | If SLD selected, must leave Minimum Dimming Level & Control options blank. SLD option requires two hot (black) wires and a shared neutral (white) wire - see installation instructions for wiring diagram. |
Accessories
Order as separate catalog numbers.
Part Number | CI Code | Description |
---|---|---|
LSXRHL | *238CAE | HIGH/LOW OCC SENSOR (see page 3 for default settings) |
LSXR10 | *219EP7 | ON/OFF OCC SENSOR |
STACG36 F1 | *208XVT | CABLE GRIPPER KIT, 36 INCH F1 CEILING TYPE |
STACG36 F2 | *208XVY | CABLE GRIPPER KIT, 36 INCH F2 CEILING TYPE |
STACG72 F1 | *208XW2 | CABLE GRIPPER KIT, 72 INCH F1 CEILING TYPE |
STACG72 F2 | *208VXW | CABLE GRIPPER KIT, 72 INCH F2 CEILING TYPE |
STACGF36 F1 | *208XW7 | KIT WITH POWER FEED, 36 INCH F1 CEILING TYPE |
STACGF36 F2 | *208XVV | KIT WITH POWER FEED, 36 INCH F2 CEILING TYPE |
STACGF72 F1 | *208XW3 | KIT WITH POWER FEED, 72 INCH F1 CEILING TYPE |
STACGF72 F2 | *208XW0 | KIT WITH POWER FEED, 72 INCH F2 CEILING TYPE |
STACGE36 F1 | *210AC1 | KIT WITH EMERGENCY POWER FEED, 36 INCH F1 CEILING TYPE |
STACGE36 F2 | *210CN1 | KIT WITH EMERGENCY POWER FEED, 36 INCH F2 CEILING TYPE |
STACGE72 F1 | *210AAV | KIT WITH EMERGENCY POWER FEED, 72 INCH F1 CEILING TYPE |
STACGE72 F2 | *210CMP | KIT WITH EMERGENCY POWER FEED, 72 INCH F2 CEILING TYPE |
Replacement Parts
Order as separate catalog numbers.
Part Number | CI Code | Description |
---|---|---|
DLBL48 | *258LR5 | REPLACEMENT DIFFUSER - ORDER QTY 2 TO REPLACE BOTH DIFFUSERS ON FIXTURE |
Performance Data
This table details the performance metrics for various lumen packages.
Lumen Package | Lumens | Input Watts | LPW (Lumens per Watt) |
---|---|---|---|
6000LM 80CRI 30K | 5970 | 49.7 | 120 |
6000LM 80CRI 35K | 6255 | 49.7 | 126 |
6000LM 80CRI 40K | 6350 | 49.7 | 128 |
6000LM 80CRI 50K | 6540 | 49.7 | 132 |
9600LM 80CRI 30K | 8956 | 80.1 | 112 |
9600LM 80CRI 35K | 9384 | 80.1 | 117 |
9600LM 80CRI 40K | 9527 | 80.1 | 119 |
9600LM 80CRI 50K | 9812 | 80.1 | 122 |
14400LM 80CRI 30K | 13467 | 112.5 | 120 |
14400LM 80CRI 35K | 14110 | 112.5 | 125 |
14400LM 80CRI 40K | 14325 | 112.5 | 127 |
14400LM 80CRI 50K | 14754 | 112.5 | 131 |
Emergency Mode Lumens Estimation: Delivered Lumens = 1.25 x P x LPW, where P is the output power of the emergency driver (10W for E10WLCP option).
Photometrics
LBL8 9600LM 80CRI 35K
Polar Candela Distribution: This graph shows the light distribution pattern of the fixture. The radial axis represents intensity in candelas (CD), with 0 CD at the center and 4300 CD at the outer edge. The angular axis ranges from 50° to 180° (top) and 0° to 40° (bottom), indicating the direction of light output. Key angles like 90° (horizontal) and 0° (vertical) are marked.
Zonal Lumen Summary: This table summarizes the percentage of total luminaire lumens emitted within specific zones (e.g., 0-30°, 0-40°, 0-60°, 60-90°, 70-100°, 90-120°, 0-90°, 90-180°, 0-180°).
Coefficients of Utilization (CU) - Zonal Cavity Method: This table provides CU values based on room reflectances (Ceiling Cavity Reflectance - CCR, Wall Reflectance - RCR) and the fixture's light distribution. It helps in calculating illuminance levels for different room configurations.
Mounting Data
Suspension Kit Ceiling Types:
- F1: For use with most T-bar and screw slot grid ceiling applications. Designed for on-grid and off-grid installations.
- F2: For use with recessed or surface-mount horizontal J-box applications.
The fixture is suitable for unit or row installation, surface or suspend mounting. Aircraft cable (STACG, STACGF, or STACGE) is required for each of the 4 suspension points. Refer to Accessories ordering tree on page 1.
Diagram Description: A technical drawing shows the fixture's dimensions and mounting points. Key dimensions include the overall length (96.00 inches / 244.0 mm), width (10.00 inches / 25.4 mm), and depth (2.75 inches / 6.98 mm). It also indicates the locations and sizes of knockout holes (.687 K.O. (4X), .875 K.O. (6X)) and slots (.25X.50 SLOT (4X)). A connection point for nLight CAT5 is also shown.
Sensor Switch LSXRHL Sensor Accessory
Lens Type: 10 - Low Mount 360° coverage
Dimming: HL - High/Low Occupancy operation
Min Dim Level: 3V - approximately 10% light output when unoccupied
Time Delay: 5M - 5 minutes