Lithonia Lighting 2GTL Series 2x2 LED Recessed Troffer
Product Specifications and Information
Features & Specifications
INTENDED USE
The 2GTL LED recessed troffer offers a wide range of lumen packages, color temperatures, and lens options to meet the lighting needs for a wide range of applications such as schools, offices, and hospitals. The light engine delivers long life and excellent color to ensure a sound quality, low-maintenance lighting installation.
Certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate. Refer to the Acrylic-Polycarbonate Compatibility table for suitable uses.
CONSTRUCTION
Housing formed from 22 gauge cold-rolled steel. Smooth hemmed sides and smooth inward formed end flanges for safe handling. Includes integral T-bar clips. Lighter-weight fixture allows for safe, easy installation.
OPTICS
Highly transmissive pattern #12 lens diffuses the light source without compromising output. Pattern #19 and satin white lens options also available.
ELECTRICAL
Long-life LEDs, coupled with high-efficiency drivers, provide extended service life. 80% LED lumen maintenance at 72,000 hours (L80/72,000).
eldoLED driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI.
Optional nLight® embedded controls make each luminaire addressable, allowing it to digitally communicate with other nLight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Simply connect all the nLight enabled control devices and the GTL luminaires using standard Cat-5 cabling. Plug-and-play convenience as devices and luminaires automatically discover each other and self-commission.
Lumen Management
Unique lumen management system (option N80) provides onboard intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting.
The step-level dimming option (SLD) allows the system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance.
Ballast disconnect is provided where required to comply with U.S. and Canadian codes.
INSTALLATION
The GTL fits into standard 15/16" and narrow 9/16" T-Grid ceiling systems. LED boards include plug-in connectors for easy upgradeability. Suitable for direct insulation contact. Suitable for damp location.
LISTINGS
CSA certified to meet U.S. and Canadian standards. IC rated. DesignLights Consortium® (DLC) Premium qualified product. Check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified.
GOVERNMENT PROCUREMENT
BAA - Product with the BAA option qualifies as a domestic end product under the Buy American Act as implemented in the FAR and DFARS. Product with the BAA option also qualifies as manufactured in the United States under DOT Buy America regulations.
BABA - Build America Buy America: Product with the BAA option also qualifies as produced in the United States under the definitions of the Build America, Buy America Act. Refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY
5-year limited warranty. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.
Specifications:
- Length: 23.75 inches (60.3 cm)
- Width: 23.75 inches (60.3 cm)
- Depth: 3.25 inches (8.2 cm)
All dimensions are in inches (centimeters) unless otherwise indicated.
A+ Capable Luminaire
This item is an A+ capable luminaire, designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning. All configurations of this luminaire meet the Acuity Brands' specification for chromatic consistency.
This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background. This luminaire provides advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background. Learn more about A+ at www.acuitybrands.com/aplus.
Ordering Information
Lead times will vary depending on options selected. Consult with your sales representative.
Series | Trim type | Length | Lumens | Door | Lens | Voltage |
---|---|---|---|---|---|---|
2GTL 2' wide recessed LED luminaire | (blank) Grid | 2' | 20L (2000 lumens) | (blank) Flush steel, white | #12 pattern acrylic, 0.110" thick | MVOLT (120-277V) |
Overlapping flange | 33L (3300 lumens) | FN Flush aluminum, natural | A12125 #12 pattern acrylic, frosted, .125" thick | 120 (120V) | ||
40L (4000 lumens) | FM Flush aluminum, matte black | A19 #19 pattern acrylic, 0.156" thick | 277 (277V) | |||
48L (4800 lumens) | FW Flush aluminum, white | SWL Satin white | 347 (347V) | |||
RN Regressed aluminum, natural | ||||||
RM Regressed aluminum, matte black | ||||||
RW Regressed aluminum, white |
Driver Options:
- EZ1: eldoLED dims to 1% (0-10V dimming)
- GZ10: Dims to 10% (0-10V dimming)
- SLD: Step-level dimming
Color Temperature Options:
- LP830: 3000 K
- LP835: 3500 K
- LP840: 4000 K
- LP850: 5000 K
Controls Options:
- (blank): No controls
- N80: nLight with 80% (L80) lumen management
- N80EMG: nLight with 80% (L80) lumen management for use with generator supply emergency power
- (blank): nLight without lumen management
- N100EMG: nLight without lumen management for use with generator supply emergency power
Options:
- BDP: Disconnect Plug
- E7W: 7W Emergency battery pack, constant power, Certified in CA Title 20 MAEDBS, User selectable Self-Diagnostic, AC Activate with Integral Test Switch (LINK)
- E10W: Emergency battery pack, 10W Linear Constant Power, Certified in CA Title 20 MAEDBS, CA Title 20 MAEDBS, User selectable Self-Diagnostic, AC Activate with Integral Test Switch (LINK)
- BGTD: Bodine Generator Transfer Device
- CP: Chicago plenum
- PWS1836: 6' pre-wire, 3/8" diameter, 18-gauge, 1-circuit
- PWS1846: 6' pre-wire, 3/8" diameter, 18-gauge, 2-circuit
- PWS1846 PWSLV: Two cables: one 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuits; one 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit w/ low voltage wires
- PWS1856LV: 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit w/ low voltage wires
- ABC: Door frame gasketing
- GLR: Fast-blowing fuse
- GMF: Slow-blowing fuse
- LATC: Earthquake clip
- NPLT: Narrow pallet
- PAF: Paint after fab
- BAA: Buy America(n) Act and/or Build America Buy America Qualified
Accessories: Order as separate catalog number.
- DGA22: Drywall grid adapter for 2x2 recessed fixture.
- 2X2SMKSHP PAF: Surface Mount Troffer Kit Post Painting upon lens option chosen.
Notes:
- 1. Lumen output will vary depending on options selected.
- 2. Not available with SLD, E7W, E10W, or BGTD.
- 3. When using pre-wire option, use PWS1846.
- 4. Not available with SLD, GZ1, GZ10.
- 5. Not available with EZ1, and SLD when combined with 40L or 48L lumen packages.
- 6. Not available with GZ1 or GZ10 when combined with 48L lumen package.
- 7. Not available with SLD. When using a pre-wire option, use PWS1846 or PWS1846 PWSLV.
- 8. Must specify voltage. Requires BSE labeling, voltage specific.
- 9. Not available with PWS1836, PWS1846, PWS1856LV, or PWS1846 PWSLV.
- 10. Not available with individual controls.
- 11. Only available with aluminum door.
- 12. Must specify voltage, 120 or 277.
Stock/Non-configurable Models
Stock/Non-configurable models are offered for shorter lead times:
Catalog Number | UPC | Description | Lumens | Color Temperature | Voltage | Wattage | Pallet qty. | Standard carton qty. |
---|---|---|---|---|---|---|---|---|
2GTL2 3300LM LP835 | 889804702637 | 2x2 LED lay-in troffer | 3277 | 3500K | 120-277 | 27.61 | 56 | 1 |
2GTL2 3300LM LP840 | 889804702460 | 2x2 LED lay-in troffer | 3408 | 4000K | 120-277 | 27.61 | 56 | 1 |
2GTL2 3300LM 347 LP835 | 889804703634 | 2x2 LED lay-in troffer, 347v | 3277 | 3500K | 347 | 30.76 | 56 | 1 |
2GTL2 3300LM 347 LP840 | 889804703900 | 2x2 LED lay-in troffer, 347v | 3408 | 4000K | 347 | 30.76 | 56 | 1 |
2GTL2 3300LM E10W LP835 | 889804704440 | 2x2 LED lay-in troffer, emergency battery | 3277 | 3500K | 120-277 | 27.61 | 12 | 1 |
2GTL2 3300LM E10W LP840 | 889804706246 | 2x2 LED lay-in troffer, emergency battery | 3408 | 4000K | 120-277 | 27.61 | 12 | 1 |
2GTL2 3700LM LP835 | 889804704143 | 2x2 LED lay-in troffer | 3702 | 3500K | 120-277 | 30.96 | 56 | 1 |
2GTL2 3700LM LP840 | 889804704242 | 2x2 LED lay-in troffer | 3850 | 4000K | 120-277 | 30.96 | 56 | 1 |
2GTL2 3700LM 347 LP835 | 889804704303 | 2x2 LED lay-in troffer, 347v | 3702 | 3500K | 347 | 34.99 | 56 | 1 |
2GTL2 3700LM 347 LP840 | 889804704365 | 2x2 LED lay-in troffer, 347v | 3850 | 4000K | 347 | 34.99 | 56 | 1 |
2GTL2 3700LM E10W LP835 | 889804706307 | 2x2 LED lay-in troffer, emergency battery | 3702 | 3500K | 120-277 | 30.96 | 12 | 1 |
2GTL2 3700LM E10W LP840 | 889804706352 | 2x2 LED lay-in troffer, emergency battery | 3850 | 4000K | 120-277 | 30.96 | 12 | 1 |
Emergency Battery Pack Options – Field Installable
Battery Model Number | Runtime (Minutes) | Lumen Output* @120 Lumens/Watt | Wattage | Other |
---|---|---|---|---|
ILB CP07 2H A | 120 | 840 | 7W | Storm Shelter/ 2 Hour Runtime |
ILB CP10 A | 90 | 1200 | 10W | Title 20; Enabled with Self Testing, Automated Reporting (STAR) |
ILB CP10 HE AELR A | 90 | 1200 | 10W | Title 20, Self Diagnostic |
ILBLP CP10 HE SD A | 90 | 1200 | 10W | Title 20, Self Diagnostic |
ILBLP CP15 HE SD A | 90 | 1800 | 15W | Title 20, Self Diagnostic |
ILB CP20 HE A | 90 | 2400 | 20W | Title 20 |
ILB CP20 HE SD A | 90 | 2400 | 20W | Title 20, Self Diagnostic |
All the above are UL Listed products that are certified for field install external/remote to the fixture.
*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.
The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast.
Contact techsupport@iotaengineering.com for any Emergency Battery related questions.
Performance Data
Lumen Package | Lumens | Input Watts | LPW |
---|---|---|---|
20L LP830 | 2203.04 | 18.39 | 120 |
20L LP835 | 2248 | 18.39 | 122 |
20L LP840 | 2337.92 | 18.39 | 127 |
20L LP850 | 2382.88 | 18.39 | 130 |
33L LP830 | 3292.8 | 28.6 | 115 |
33L LP835 | 3360 | 28.6 | 117 |
33L LP840 | 3494.4 | 28.6 | 122 |
33L LP850 | 3561.6 | 28.6 | 125 |
40L LP830 | 3756.34 | 33.61 | 112 |
40L LP835 | 3833 | 33.61 | 114 |
40L LP840 | 3986.32 | 33.61 | 119 |
40L LP850 | 4062.98 | 33.61 | 121 |
48L LP830 | 4759.86 | 41.95 | 113 |
48L LP835 | 4857 | 41.95 | 116 |
48L LP840 | 5051.28 | 41.95 | 120 |
48L LP850 | 5148.42 | 41.95 | 123 |
Note: Performance based on standard #12 pattern acrylic lens.
PHOTOMETRICS
2GTL 2 33L LP835, 3399 delivered lumens, test no. ISF 36873P6, tested in accordance to IESNA LM-79.
How to Estimate Delivered Lumens in Emergency Mode
Use the formula below to estimate the delivered lumens in emergency mode:
Delivered Lumens = 1.25 x P x LPW
P = Output power of emergency driver. P = 10W for E10WLCP option.
LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet.
MOUNTING DATA
G: Lay-in Grid (exposed or concealed grid)
F: Overlapping Flanged Trim with swing-gate hangers
NOTE: Increased rough-in dimensions for F-trim fixtures 24"x24" (Tolerance is +1/4"-0"). Swing-gate range 1-3/16" to 3-15/16". Swing-gate span 23-3/8" to 26-11/16". Fixture swing-gate points require additional 1-1/16" over nominal fixture height.
BSE Labeling Options
- BSE10: Drivers load transfer relay installed per manufacturer's instructions. Voltage, BGTD and BSE10 called out.
- BSE14: One voltage fixture with driver load control relay supplied with one prewire (PWS option). Prewire wired for normal circuit, the control relay for emergency circuit left unconnected. Voltage, BGTD, BSE14 and prewire called out, in the description.
*For configurations with Reloc or two voltages an RFA modification is required.
Constant Lumen Management
Enabled by the embedded nLight control, the GTL actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting.
Without Lumen Management
Energy is wasted and light level is inconsistent.
With Lumen Management
Energy is saved and light level remains consistent.
Enabled with STAR
Emergency Lighting with Self-Testing Automated Reporting (STAR) enables self-testing and automated reporting to aid in life safety code compliance. Build your solution and choose your preferred deployment from Mobile STAR, where test data is logged in each individual unit and broadcast to the CLAIRity™+ app, or Connected STAR, where test data is logged in the STAR Gateway by IOTA® and emailed directly. Leave the ladders, disruptions and written records behind with emergency lighting solutions with STAR!
Life Safety Code NFPA 101 testing and reporting requirements for emergency lighting include:
- Testing for 30 seconds every 30 days
- Testing for 90 minutes once a year
- Record keeping and to report to the authority having local jurisdiction
MOBILE STAR
For small scale applications
CONNECTED STAR
For large scale applications
Related Documents
![]() |
Lithonia Lighting GTL LED Recessed Troffer - Features, Specifications, and Ordering Explore the Lithonia Lighting GTL LED recessed troffer, a versatile lighting solution for schools, offices, and hospitals. This document details its features, specifications, electrical components, installation guidelines, and ordering information, including A+ capable options and STAR enabled emergency lighting. |
![]() |
Lithonia Lighting 2GTL LED Recessed Troffer - Features, Specifications, and Ordering Detailed information on the Lithonia Lighting 2GTL LED recessed troffer, including features, construction, electrical specifications, installation guidelines, and ordering options. Learn about its energy efficiency, lumen management, and control capabilities. |
![]() |
Lithonia Lighting 2GTL Series LED Recessed Troffer - Product Specifications and Ordering Explore the Lithonia Lighting 2GTL Series 2'x4' LED Recessed Troffer. This document details features, specifications, ordering information, performance data, and photometrics for this energy-efficient lighting solution suitable for commercial and institutional applications. |
![]() |
Lithonia Lighting 2GTL LED Recessed Troffer - Features, Specifications, and Ordering Detailed information on the Lithonia Lighting 2GTL LED recessed troffer, including its features, specifications, construction, optics, electrical components, installation guidelines, and ordering options. This document covers lumen packages, color temperatures, control options like nLight, and emergency lighting capabilities. |
![]() |
Lithonia Lighting 2GTL LED Recessed Troffer - Specifications and Ordering Comprehensive technical specifications, performance data, ordering information, and features for the Lithonia Lighting 2GTL 2'x4' LED recessed troffer, highlighting its A+ capable design, lumen packages, and nLight control compatibility. |
![]() |
Lithonia Lighting 2BLT4R LED Relight Troffer: Features, Specifications, and Controls The Lithonia Lighting 2BLT4R is a 2'x4' LED relight troffer designed for efficient retrofitting of existing fluorescent fixtures. It offers high lumen output, multiple diffuser options, integrated nLight and SensorSwitch controls, and optional emergency battery packs. |
![]() |
Lithonia Lighting 2BLT2R: 2'x2' LED Relight Fixture - Features, Specs, and Controls Explore the Lithonia Lighting 2BLT2R, a 2'x2' LED relight fixture designed for efficient retrofitting of fluorescent troffers. This document details its features, specifications, advanced nLight and SensorSwitch control options, installation guidance, performance data, and compliance information. |
![]() |
Lithonia Lighting STACK LED Center Element Troffer: Features, Specifications, and Controls Detailed information on the Lithonia Lighting STACK LED Center Element Troffer, covering its features, construction, installation, electrical specifications, optics, listings, warranty, ordering options, integrated controls (nLight, SensorSwitch), accessories, photometrics, and performance data for commercial and indoor applications. |