Eurolite LED IP PAR 9 UV Spot
UV Outdoor Spotlight
User Manual
Introduction
Thank you for choosing one of our products. This manual provides important information for the correct use of the device. Following the instructions in this manual will ensure you enjoy this device for a long period of time.
Product Features
- Weatherproof (IP65) spotlight with 9 UV LEDs, including IR remote control.
- 9 x 3W high-power UV LEDs.
- Suitable for outdoor use (IP65).
- Modes: Auto, Master/Slave, and DMX.
- Built-in auto show programs.
- Dimmer and strobe effect.
- Addressing and settings via control panel with LCD display and 4 operating buttons.
- Convenient wireless control via included IR remote control EUROLITE IR-7.
- DMX512 control possible via any commercial DMX controller.
- Selectable DMX channels: 1, 2, or 4.
- Swivel mounting bracket.
- Additional bracket for floor standing.
- IP T-Con power linking for up to 8 units.
- Power connection via IP T-Con jack and included power cable with safety plug.
Safety Instructions
WARNING! Please read the safety warnings carefully and use the product only as described in this manual to avoid accidental injury or damage.
Intended Use
- This device is a spotlight for creating decorative lighting effects, designed for professional use in event technology (e.g., on stage). It is not suitable for household lighting.
- Use the device only according to the instructions. Failure to follow these instructions voids the warranty. No liability is assumed for resulting damage.
- No liability is assumed for material and personal damage caused by improper use or non-compliance with safety instructions.
- Unauthorized modifications are not permitted for safety reasons and void the warranty.
Danger due to Electricity
- The product is supplied with dangerous mains voltage. Never open the device; there are no user-serviceable parts inside.
- Connect only to a properly installed mains outlet protected by an RCD. Ensure voltage and frequency match the device's rating. Connect to a grounded outlet if the cable has an earth contact. Never deactivate the protective ground.
- For outdoor use, use rubber cable H05RN-F or H05RR-F. For underground installations, use NYY cable. Adhere to all outdoor/ground cable installation regulations.
- Ensure the mains outlet is easily accessible for quick unplugging.
- Never touch the mains plug with wet hands.
- Do not bend or squeeze the mains cable. Keep it away from hot surfaces and sharp edges.
- Always pull the plug, not the cable, to disconnect.
- Unplug during lightning storms, long periods of non-use, or before cleaning.
- Do not expose to extreme temperatures, direct sunlight, strong vibrations, or heavy mechanical stress.
- Do not immerse the product in water; this will destroy it and can cause electric shock.
- Repairs must only be carried out by qualified personnel if the device or cable is visibly damaged, dropped, or malfunctions occur.
Danger to Children and People with Restricted Abilities
- This product is not a toy. Keep out of reach of children and pets. Do not leave packaging material carelessly. Never leave the device running unattended.
- The device may only be used by persons with sufficient physical, sensory, and intellectual abilities and knowledge. Others may use it only if supervised or instructed by a responsible person.
Warning - Risk of Burns and Fire
- Admissible ambient temperature (Ta): -5 to +45°C. Do not operate outside this range.
- Housing temperature (Tc) can reach up to 60°C during use. Avoid contact.
- Maintain a minimum distance of 1m from illuminated surfaces.
- Keep away from flammable materials. Ensure sufficient air circulation (50cm clearance). Do not cover air vents.
Warning - Risk of Injuries
- Do not look directly at the light source (risk of epileptic seizures for sensitive individuals).
- Ensure the product is installed safely and securely to prevent falling. Comply with relevant standards (e.g., EN 60598-2-17).
- If unqualified, do not attempt installation; use a professional installer. Improper installation can cause injury or property damage.
- Manufacturer is not liable for damages from incorrect installations or insufficient safety precautions.
- For overhead use, always secure with a secondary attachment (safety bond/net).
- Block the area below during installation, rigging, or servicing.
- Comply with country-specific accident prevention regulations for commercial use.
Caution - Material Damage
- Do not connect to mains voltage via a dimmer.
- Lighting effects are not designed for permanent operation; use breaks to prolong service life.
- Avoid frequent switching on/off, as this reduces service life.
- If exposed to drastic temperature fluctuations, do not switch on immediately. Allow the device to reach room temperature to prevent condensation damage.
- Use original packaging for transport/storage protection.
- Do not remove the serial number label, as this voids the warranty.
About Batteries
- Do not short-circuit, recharge, disassemble, or heat batteries (explosion risk!).
- Remove batteries if the device is not used for a longer period.
- Handle damaged/leaking batteries with suitable gloves to avoid skin irritation.
Description of the Device
The device features the following components:
- 1. Infrared sensor for remote control: Receives signals from the IR remote.
- 2. 3W UV LEDs: Nine high-power UV LEDs provide the lighting effect.
- 3. Housing: The main body of the unit.
- 4. Fixation screw: Used for adjusting the mounting bracket angle.
- 5. DMX input: 3-pin XLR male connector for receiving DMX signals.
- 6. Pressure compensation plug: Helps equalize pressure, often for weatherproofing.
- 7. Safety rope eyelet: Attachment point for a secondary safety cable.
- 8. LCD display with operating buttons: For viewing settings and controlling the device.
- 9. DMX output: 3-pin XLR female connector for daisy-chaining to other DMX devices.
- 10. Power input: IP T-Con connector for power supply.
- 11. Power output: IP T-Con connector for powering other devices (power linking).
- 12. Mounting/stand bracket: Allows for hanging or floor standing.
Installation
WARNING! Risk of injury caused by falling objects. Ensure secure installation by a specialist.
The device can be placed on the floor by unfolding the brackets or fastened to a truss or similar rigging structure. It must never be fixed swinging freely.
- The rigging structure must support at least 10 times the weight of all fixtures.
- Block access below the work area and work from a stable platform.
- Use compatible rigging hardware. Refer to the "Accessories" section for suitable options.
- Secure the device with a safety rope or other secondary attachment. This must be adequately dimensioned and installed to prevent parts from falling if the main attachment fails. Fasten the safety rope so the maximum drop distance does not exceed 20 cm.
- To align the device, release the fixation screws on the mounting bracket, adjust the desired inclination angle, and tighten the screws.
- Periodically inspect the device after installation to prevent corrosion, deformation, or looseness.
DMX512 Control
A DMX512 data link is required for DMX control. The device uses 3-pin XLR connectors.
Connection:
- Connect your DMX controller's output to the device's DMX IN using a DMX cable.
- Connect the DMX OUT of one unit to the DMX IN of the next unit in the chain.
- At the last unit, terminate the DMX cable with a 120 Ω resistor between Signal (-) and Signal (+).
- For cable lengths over 300m or more than 32 devices, a DMX signal amplifier is recommended.
XLR Pinout:
- DMX Output (Socket): 1: Ground, 2: Signal (-), 3: Signal (+)
- DMX Input (Plug): 1: Ground, 2: Signal (-), 3: Signal (+)
Setup:
- Select DMX mode via the menu.
- Choose the number of DMX channels (1, 2, or 4 CH).
- Set the DMX start address (ADDR:***).
- If no DMX signal is received, the display will flash.
Ensure that control channels do not overlap with other devices for independent operation. Devices addressed similarly will work synchronously.
Functions in DMX Mode
1-Channel Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | UV 0-100% |
2-Channel Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Total brightness 0-100% |
2 | 000-009 | No function |
010-255 | Strobe slow > fast 0-100% |
4-Channel Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Total brightness 0-100% |
2 | 000-009 | No function |
010-255 | Strobe slow > fast 0-100% | |
3 | 000-255 | UV 0-100% |
4 | 000-009 | No function |
010-069 | Auto program 1 | |
070-129 | Auto program 2 with increasing speed | |
130-189 | Auto program 3 | |
190-255 | Auto program 4 with increasing speed |
Power Supply
The device uses an auto-range power supply (100-240V AC).
- Connect the device via the mains cable to a grounded mains socket to switch it on.
- Disconnect the power plug to switch off the unit.
- Do not connect via a dimmer. Use a switchable outlet for convenience.
- The POWER OUT jack allows powering other devices. Link units using POWER OUT to POWER IN connections. Up to 8 devices can be linked at 230/240V, and up to 4 devices at 110/115V. Matching power cables are available as accessories.
- Close open contacts with caps to prevent moisture and dirt ingress.
Operation
After connecting to mains, the device is ready. Settings are stored when power is disconnected. Operation is possible in stand-alone mode (control panel/IR remote) or DMX-controlled mode.
Menu Structure
Mode | Display | Function |
---|---|---|
DMX mode | 4-CH ADDR:001-512 | 4-channel mode and start address |
2-CH ADDR:001-512 | 2-channel mode and start address | |
1-CH ADDR:001-512 | 1-channel mode and start address | |
Automatic mode | AUTO | Auto program |
Running speed in automatic mode | SPEED | Program running speed (slow > fast) |
Individual brightness | COLOR | UV 0-100% |
Dimmer | DIMMING | Total brightness (dark > bright) |
In and out fading | FADING | Fade-in/out of UV LEDs (slow > fast) |
Strobe effect | FLASH | Strobe effect (slow > fast) |
Blackout | LEDs go off | |
Behaviour in case of missing DMX signal | Hold | Spot holds the last received signal |
Full | All LEDs 100% on | |
Auto | Pre-selected static color 01-04 | |
Slave mode | SLAVE | Slave mode |
Key lock | PASSCODE | Key lock on/off |
IR remote control | INFRARED | IR remote control on/off |
Firmware version | V1.0 | Firmware version number |
Stand-alone Mode
Automatic Mode
Select one of 4 show programs and adjust speed (01-09).
- Press MENU until AUTO is displayed, then ENTER. Use UP/DOWN to select program (01-04), then ENTER.
- Press MENU until SPEED is displayed, then ENTER. Use UP/DOWN to set speed (01-09), then ENTER.
Individual Brightness
Adjust the brightness of each UV LED (0-100%).
- Press MENU until COLOR is displayed, then ENTER.
- Use UP/DOWN to adjust UV LED brightness.
- Confirm with ENTER.
Total Brightness
Adjust overall brightness (01-99).
- Press MENU until DIMMING is displayed, then ENTER.
- Use UP/DOWN to set brightness (01=dark, 99=bright), then ENTER.
Fade-in and Fade-out
Adjust the speed for fading UV LEDs (00-99).
- Press MENU until FADING is displayed, then ENTER.
- Use UP/DOWN to set speed (00-99), then ENTER.
Strobe Effect
Adjust the speed for the strobe effect (00-99).
- Press MENU until FLASH is displayed, then ENTER.
- Use UP/DOWN to set speed (00-99), then ENTER.
Behaviour at Missing DMX Signal
Select behavior when no DMX signal is received.
- Press MENU repeatedly until DMX lost is displayed, then ENTER.
- Use UP/DOWN to select the desired program, then ENTER.
Interconnecting Devices (Master/Slave Operation)
Up to 32 devices can be synchronized. The master unit controls slave units without a DMX controller.
- Configure slave units first: Press MENU until SLAVE is displayed, then ENTER.
- Connect DMX OUT (Master) to DMX IN (Slave 1), then DMX OUT (Slave 1) to DMX IN (Slave 2), etc. Master must be the first unit in the chain. Do not connect a DMX controller to the Master's DMX IN.
- Set the master unit to the desired operating mode. Devices will operate in sync.
PASSCODE (Key Lock)
Locks control panel buttons to prevent tampering. Keys lock automatically after the last command. To deactivate, press UP, DOWN, UP, DOWN, ENTER.
Remote Control IR-7
Activate remote control by setting INFRARED to ON. Always point the remote at the sensor with a clear line of sight.
Button | Function |
---|---|
BLACKOUT | LEDs off |
AUTO | Automatic mode; program selection with (+)/(-) |
STROBE | Strobe effect for automatic; flash rate setting with (+)/(-) |
SPEED | Running speed in automatic mode; setting with (+)/(-) |
DMX | DMX mode |
MANUAL | LED select with UV |
FADE | Fading in/out of LEDs; running speed setting with (+)/(-) |
1-9 | Total brightness; 1 = dark, 9 = bright |
Notes: The remote is supplied with a battery. Remove the insulating foil before first use. Replace battery (CR2025) if range decreases. Remove battery for long-term storage.
DMX Operation
Set DMX channels and start address for controller operation. The device supports 1, 2, or 4 channels.
- Press MENU until DMX is displayed, then ENTER.
- Use UP/DOWN to select channel count (1 CH, 2 CH, or 4 CH), then ENTER.
- Set DMX start address (ADDR:***) using UP/DOWN, then ENTER.
- Display flashes if no DMX control signals are received.
Ensure no overlapping channels for correct, independent control. Similarly addressed devices work synchronously.
Cleaning and Maintenance
Clean the exterior periodically to remove dust. Pay special attention to lenses for maximum brightness.
- Disconnect from power and allow to cool before cleaning.
- Clean surfaces with a soft, lint-free, moistened cloth. Avoid alcohol or solvents. Ensure no liquids enter the device.
- The device must be dry before reapplying power.
No user-serviceable parts inside. Do not open or attempt repairs. Maintenance and service operations are to be carried out by authorized dealers only. Use genuine spare parts.
Protecting the Environment
Dispose of old equipment at a local recycling plant. Do not dispose of as household waste. Remove and dispose of batteries separately.
As an end user, you are legally required to return all used batteries/rechargeable batteries. Disposal in household waste is prohibited. Return used batteries free of charge to collection points.
Technical Specifications
Parameter | Specification |
---|---|
Power supply | 100-240 V AC, 50/60 Hz |
Power consumption | 30 W |
IP classification | IP65 |
Protection class | Class I |
Power connection | Mains input IP T-Con (M) with safety plug (provided) |
Power output | IP T-Con (F) |
LED | 9 x high-power 3W UV |
Photobiological safety | Risk Group 0 |
Flash rate | 0 - 20 Hz |
DMX channels | 1, 2, 4 |
DMX input | 3-pin XLR (M) mounting version IP |
DMX output | 3-pin XLR (F) mounting version IP |
Cooling | Passive convection |
Control | Stand-alone; DMX; IR remote control; Master/Slave function |
Beam angle (1/2 peak) | 20° |
Beam angle (1/10 peak) | 50° |
Wavelength | 365 nm |
Housing color | Black |
Display type | LCD |
Dimensions | Width: 28.90 cm, Depth: 15.25 cm, Height: 33.80 cm |
Weight | 4.80 kg |
Remote control battery | 1 x Button cell 3.0V CR2025 Lithium Manganese (provided) |
Accessories
- EUROLITE TPC-10 Coupler, black (Part No. 59006858)
- EUROLITE Safety Bond UNV-5 3x600mm up to 5kg silver (Part No. 58010372)
- PSSO DMX Cable IP65 3pin 1.5m black (Part No. 3022783A)
- EUROLITE IR-7 Remote Control (Part No. 50530561)
All information is subject to change without prior notice. © 31.07.2023