HOBO MX Temp/RH Data Logger (MX1101) Manual

HOBO MX Temp/RH Data Logger

The HOBO MX Temp/RH data logger records and transmits temperature and relative humidity (RH) in indoor environments with its integrated sensors. This Bluetooth® Low Energy (BLE)-enabled logger is designed for wireless communication with a phone, tablet, or computer. Using the HOBOconnect® app, you can easily configure the logger and then download logged data to view or export for further analysis. The logger can calculate minimum, maximum, average, and standard deviation statistics and can be configured to trip audible or visual alarms at thresholds you specify. The logger also supports burst logging in which data is logged at a different interval when sensor readings are above or below certain limits. This compact data logger also has a built-in LCD screen to display the current temperature, relative humidity, logging status, battery use, memory consumption, and more.

Specifications

Temperature Sensor

Range-20° to 70°C (-4° to 158°F)
Accuracy±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
Resolution0.024°C at 25°C (0.04°F at 77°F), see Plot A
Drift<0.1°C (0.18°F) per year

RH Sensor*

Range1% to 90% (non-condensing)
Accuracy±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution0.01%
Drift<1% per year typical

Response Time

Temperature7:30 minutes in air moving 1 m/s (2.2 mph)
RH20 seconds to 90% in airflow of 1 m/s (2.2 mph)

Logger

Radio Power1 mW (0 dBm)
Transmission RangeApproximately 30.5 m (100 ft) line-of-sight
Wireless Data StandardBluetooth Low Energy (Bluetooth Smart)
Logger Operating Range-20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Logging Rate1 second to 18 hours
Logging ModesFixed interval (normal, statistics) or burst
Memory ModesOverwrite when full or stop when full
Start ModesImmediate, push button, date and time, or next interval
Stop ModesWhen memory is full, push button, date and time, or after a set logging period
Restart ModePush button
Time Accuracy±1 minute per month at 25°C (77°F), see Plot B
Battery Life1 year, typical with logging interval of 1 minute. Faster logging and/or statistics sampling intervals, entering burst logging mode, and remaining connected with the app affects battery life. Excessive readouts, audible alarms, and paging all affect battery life. Visual alarms and other events can have a marginal effect on battery life.
Battery TypeTwo AAA 1.5 V alkaline batteries, user replaceable
Memory128 KB (84,650 measurements, maximum)
Full Memory Download TimeApproximately 60 seconds; may take longer the further the device is from the logger

*Per RH sensor manufacturer data sheet

Specifications (continued)

LCDLCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size3.66 x 8.48 x 2.29 cm (1.44 x 3.34 x 0.9 in.)
Weight56 g (1.98 oz)
Environmental RatingIP50
CEThe CE Marking identifies this product as complying with all relevant directives in the European Union (EU).
FCSee last page

*Per RH sensor manufacturer data sheet

Plot A: Temperature Accuracy and Resolution
Plot B: Time Accuracy

Logger Components and Operation

Start/Stop Button: Press this button for 3 seconds to start or stop logging data, or to resume logging on the next even logging interval. This requires configuring the logger in the app with a push button start or stop, and with Allow Button Restart selected. You can also press this button for 1 second to record an internal event, to silence a beeping alarm, or to turn the LCD screen on if the option to turn off the LCD has been enabled.

Press both the Start/Stop button and the Alarm/Stats button simultaneously for 3 seconds to reset a logger password.

Alarm/Stats Button: Press this button for 1 second to switch between statistics, alarm readings, and the current sensor readings as applicable or to silence a beeping alarm. Press this button for 3 seconds to clear a visual alarm if the logger is configured in the app to maintain the visual alarm until the alarm button is pressed.

Mounting Loops: Use the two mounting loops (only one visible in the diagram) to mount the logger with the hook-and-loop strap.

Temperature Sensor: This sensor is located in the lower left corner of the raised panel to the right of the LCD screen.

RH Sensor: This sensor is located behind the vented panel in the logger case to the right of the LCD screen and the temperature sensor.

LCD Screen: This logger is equipped with an LCD screen that displays details about the current status. This example shows all symbols illuminated on the LCD screen followed by definitions of each symbol in the table on the next page.

LCD Symbol Definitions:

LCD SymbolDescription
STARTThe logger is waiting to be started or restarted. Press and hold the Start/Stop button for 3 seconds to start the logger.
STOPThe logger has been started with push button stop enabled; press and hold the Start/Stop button for 3 seconds to stop the logger.
MEMORYThe battery indicator shows the approximate battery power remaining.
MEMORYThe logger has been configured to stop logging when memory fills. The memory bar indicates the approximate space remaining in the logger to record data. When first started, all five segments in the bar are empty. In this example, the logger memory is almost full (only one segment in the memory bar is empty).
LOGGINGThe logger has been configured to never stop logging. The logger continues recording data indefinitely, with newest data overwriting the oldest data until the batteries die or the logger is reconfigured. When first launched, all five segments in the memory bar are empty. In this example, the memory is full (all five segments are filled in) and new data is now overwriting the oldest data. This continues until the logger is stopped or the battery runs out.
CLEARThe logger is currently logging.
max min avg sdoA sensor reading is above or below the high or low alarm limit that you configured. Press and release the Alarm/Stats button until the "alm" symbol is displayed on the screen. This symbol at left clears depending on how visual alarms are configured in the app. If the visual alarm is set to clear when the logger is reconfigured, this symbol remains on the LCD until the next time new configuration settings are loaded onto the logger. Otherwise, it clears when the sensor reading is back within the alarm limits or by pressing the Alarm/Stats button for 3 seconds.
almA visual alarm is ready to be cleared. This appears only if the app is configured to maintain the visual alarm until the alarm button is pressed. Press the Alarm/Stats button for 3 seconds to clear the visual alarm. Note that you can silence an audible alarm by pressing the Start/Stop button or Alarm/Stats button for 1 second.
68.0This is an example of a temperature reading. Temperature units are determined by the settings in the app. To switch between Celsius and Fahrenheit, change the units in the app settings (you must reconfigure the logger for units changes to take effect).
05:38 m:sThe logger has been configured to start logging on a particular date/time. The display counts down in days, hours, minutes, and seconds until logging begins. In this example, 5 minutes and 38 seconds remain until logging begins.
%RHThis is an example of an RH reading.
LoAdThe configured settings are being loaded onto the logger from the app.
ErrAn error occurred while loading the configuration settings onto the logger from the app. Try reconfiguring the logger.
StopThe logger has been stopped with the app or because the memory is full.

Notes:

Downloading the App and Connecting to a Logger

  1. Download the app. Download HOBOconnect to a phone or tablet from the App Store® or Google Play™ or download the app to a Windows computer from www.onsetcomp.com/products/software/hoboconnect.
  2. Install the batteries. Open the battery door on the back of the logger and insert two AAA batteries observing polarity. Reinsert the battery door and snap it back into place.
  3. Open the app. Enable Bluetooth in your device settings if prompted.
  4. Connect to the logger. Tap Devices and then tap the logger tile in the app to connect to it.

Configuring the Logger

Use the app to set up the logger, including setting alarms, selecting the options to start and stop logging, and choosing a logging mode. These steps provide an overview of setting up the logger. For complete details, see the HOBOconnect User Guide.

  1. In the app, tap Devices and then tap the logger tile to connect to it.
  2. Tap Configure & Start to configure the logger.
  3. Tap Name and type a name for the logger (optional). If you do not enter a name, the app uses logger serial number as the name.
  4. Tap Group to add the logger to a group (optional).
  5. Tap Logging Interval and choose how frequently the logger will record data unless operating in burst logging mode (see Burst Logging).
  6. Tap Start Logging and select when logging begins:
    • On Save. Logging begins immediately after configuration settings are saved.
    • On Next Interval. Logging begins at the next even interval as determined by the selected logging interval.
    • On Button Push. Logging begins when you press either the Start/Stop logging button on the logger for 3 seconds or start logging with the app.
    • On Date/Time. Logging begins at a date and time you specify. Select the Date and Time.
  7. Tap Stop Logging and specify when logging ends:
    • Never Stop (Overwrites Old Data). The logger does not stop at any predetermined time. The logger continues recording data indefinitely, with newest data overwriting the oldest.
    • On Date/Time. The logger stops logging on a specific date and time that you specify.
    • After. Select this if you want to control how long the logger should continue logging once it starts. Choose the amount of time you want the logger to log data. For example, select 30 days if you want the logger to log data for 30 days after logging begins.
    • Stop When Memory Fills. The logger continues recording data until the memory is full.
  8. Tap Pause Options, then select Pause On Button Push to specify that you can pause the logger by pressing its button for 3 seconds. Select Allow Button Resume to specify that you can press the Start/Stop button on the logger to resume logging.

Important: When you select Allow Button Resume and you use the Start/Stop button on the logger to stop and restart logging, logging restarts on the next even logging interval, not at the time you pushed the button. For example, a logger started logging at 7:00 AM with a logging interval set to 1 hour. If you press the Start/Stop button to stop the logger at 8:45 AM and then press the button again at 10:15 AM, logging will not begin immediately at 10:15 AM. Instead, logging will begin again at 11:00 AM, which is the next even interval time based on your 1-hour logging interval. Depending on the logging interval, the gap between the time you press the button to resume logging and the time actual logging begins could be significant. The faster the logging interval, the less time elapses before logging resumes.

  1. Tap Logging Mode. Select either fixed or burst logging. With fixed logging, the logger records data for all enabled sensors and/or selected statistics at the logging interval selected. In burst mode, logging occurs at a different interval when a specified condition is met.
  2. Enable or disable Show LCD, which controls whether the LCD on the logger remains illuminated while the logger is logging. If you disable Show LCD, the LCD on the logger does not show the current reading, status, or other information while the logger is logging. You can temporarily turn the LCD screen on by pressing the Start/Stop button on the logger for 1 second. In addition, you can always view the status of any in-range logger on your mobile device regardless of the logger's LCD setting (may require a logger password as applicable).
  3. Select the sensor measurement types that you want to log. By default, both the temperature and RH sensors are enabled. Both sensors are required to calculate dew point, which is an additional data series available for plotting after downloading data from the logger. You can also set up alarms to trip when a sensor reading rises above or falls below a specified value. See Setting up Alarms for details on enabling sensor alarms and selecting the associated audible and visual alarm settings.
  4. Select whether to upload data to HOBOlink® via the gateway or the app (optional and requires an active HOBOlink account).
  5. Tap Start to save the configuration settings. Logging begins based on the settings you selected. Press the start button on the logger if you set it up to start logging with a button push. Deploy the logger using the mounting materials. After logging begins, you can read out the logger at any time.

Setting up Alarms

You can set an alarm to trip on the logger when a sensor reading rises above or falls below a specified value. This alerts you to problems so you can take corrective action. To set an alarm:

  1. Tap Devices.
  2. Tap the logger tile in the app to connect to it and tap Configure & Start.
  3. Tap a Sensor/Channel.
  4. Tap Enable Logging, if necessary.
  5. Tap Alarms to open that area of the screen.
  6. Select Low if you want an alarm to trip when the sensor reading falls below the low alarm value. Enter a value to set the low alarm value.
  7. Select High if you want an alarm to trip when the sensor reading rises above the high alarm value. Enter a value to set the high alarm value.
  8. For the Duration, select how much time should elapse before the alarm trips and select one of the following:
    • Cumulative Samples. The alarm trips once the sensor reading is out of the acceptable range for the selected duration any time during logging. For example, if the high alarm is set to 85°F and the duration is set to 30 minutes, then the alarm trips once the sensor readings have been above 85°F for a total of 30 minutes since the logger was configured.
    • Consecutive Samples. The alarm trips once the sensor reading is out of the acceptable range continuously for the selected duration. For example, the high alarm is set to 85°F and the duration is set to 30 minutes, then the alarm trips only if all sensor readings are 85°F or above for a continuous 30-minute period.
  9. Repeat steps 2-8 for the other sensor.
  10. In the Alarm Settings area, enable Audible Alarm if you want a beep to sound on the logger every 30 seconds when the sensor alarm trips. The beeping continues until you clear the alarm in the app, press either button on the top of the logger, or 7 days have passed. Battery life is slightly reduced when this setting is enabled. It is recommended that you enable this feature only if you have regular access to the logger so that you can easily turn off the beeping.
  11. For Show Visual Alarms Until, select one of the following options to determine how long the alarm icon remains illuminated on the logger LCD screen after an alarm trips:
    • Logger Reconfigured. The alarm icon remains visible on the LCD until the next time the logger is reconfigured.
    • Sensor in Limits. The alarm icon remains visible on the LCD until the sensor reading returns to the normal range between any configured high and low alarm limits.
    • Alarm Button Pressed. The alarm icon remains visible until you press the Alarm/Stats button on the logger.

Notes:

Burst Logging

Burst logging is a logging mode that allows you to set up more frequent logging when a specified condition is met. For example, a logger is recording data at a 5-minute logging interval and burst logging is configured to log every 30 seconds when the temperature rises above 85°F (the high limit) or falls below 32°F (the low limit). This means the logger records data every 5 minutes as long as the temperature remains between 85°F and 32°F. Once the temperature rises above 85°F, the logger switches to the faster logging rate and records data every 30 seconds until the temperature falls back to 85°F. At that time, logging then resumes every 5 minutes at the fixed logging interval. Similarly, if the temperature falls below 32°F, then the logger switches to burst logging mode again and record data every 30 seconds. Once the temperature rises back to 32°F, the logger then returns to fixed mode, logging every 5 minutes. Note: Sensor alarms, statistics, and the Stop Logging option Never Stop (Overwrites Old Data) are not available in burst logging mode.

To set up burst logging:

  1. Tap Devices. Press the Start/Stop button on the logger to wake it up, if necessary.
  2. Tap the logger tile in the app to connect to the logger and tap Configure & Start.
  3. Tap Logging Mode and then tap Burst Logging.
  4. Set the burst logging interval, which must be faster than the logging interval. Keep in mind that the faster the burst logging rate, the greater the impact on battery life and the shorter the logging duration. Because measurements are being taken at the burst logging interval throughout the deployment, the battery usage is similar to what it would be if you had selected this rate for the normal logging interval.
  5. Select Low and/or High and type a value to set the low and/or high values.
  6. Repeat step 5 for the other sensor if desired.

Notes:

Statistics Logging

During fixed logging, the logger records data for enabled sensors and/or selected statistics at the logging interval selected. Statistics are calculated at a sampling rate you specify with the results for the sampling period recorded at each logging interval. You can log the following statistics for each sensor:

For example, a logger is configured with both the temperature and RH sensors enabled, and the logging interval set to 5 minutes. The logger is set to Fixed Logging Mode and all four statistics are enabled and with a statistics sampling interval of 30 seconds. Once logging begins, the logger measures and records the actual temperature and RH sensor values every 5 minutes. In addition, the logger takes a temperature and RH sample every 30 seconds and temporarily stores them in memory. The logger then calculates the maximum, minimum, average, and standard deviation using the samples gathered over the previous 5-minute period and logs the resulting values. When downloading data from the logger, this results in 10 data series (not including any derived series, such as dew point): two sensor series (with temperature and RH data logged every 5 minutes) plus eight maximum, minimum, average, and standard deviation series (four for temperature and four for RH with values calculated and logged every 5 minutes based on the 30-second sampling).

To log statistics:

  1. Tap Devices. Press the Start/Stop button on the logger to wake it up, if necessary. Tap the logger tile in the app to connect to it and tap Configure & Start.
  2. Tap Logging Mode and select Fixed Logging Mode.
  3. Tap to turn on Statistics.

Note: Fixed Logging Mode records sensor measurements taken at each logging interval. The selections you make in the Statistics section add measurements to the recorded data.

  1. Select the statistics you want the logger to record at each logging interval: Maximum, Minimum, Average, and Standard Deviation (average is automatically enabled when selecting Standard Deviation). Statistics are logged for all enabled sensors. In addition, the more statistics you record, the shorter the logger duration and the more memory is required.
  2. Enter a value in Statistics Sampling Interval to use for calculating statistics. The rate must be less than, and a factor of, the logging interval. For example, if the logging interval is 1 minute and you select 5 seconds for the sampling rate, the logger takes 12 sample readings between each logging interval (one sample every 5 seconds for a minute) and use the 12 samples to record the resulting statistics at each 1-minute logging interval. Note that the faster the sampling rate, the greater the impact on battery life. Because measurements are being taken at the statistics sampling interval throughout the deployment, the battery usage is similar to what it would be if you had selected this rate for the normal logging interval.

Once logging begins, press the Alarm/Stats button on the logger to cycle through the current maximum, minimum, average, and standard deviation data on the LCD screen. Note that the logger always displays the current sensor readings in the app even if they are not being logged. You can plot the statistics series once you read out the logger.

Setting a Password

You can create an encrypted password for the logger that is required if another device attempts to connect to it. This is recommended to ensure that a deployed logger is not mistakenly stopped or purposely altered by others. This password uses a proprietary encryption algorithm that changes with every connection.

To set a password:

  1. Tap Devices. Press the Start/Stop button on the logger to wake it up, if necessary. Tap the logger tile in the app to connect to it.
  2. Tap Lock Logger.
  3. Type a password and then tap Set.

Only the device used to set the password can then connect to the logger without entering a password; all other devices are required to enter the password. For example, if you set the password for the logger with your tablet and then try to connect to the logger later with your phone, you must enter the password on the phone but not with your tablet. Similarly, if others attempt to connect to the logger with different devices, they are also required to enter the password. To reset a password, press the circle on the logger for 10 seconds or connect to the logger and tap Manage Password and tap Reset.

Downloading Data From the Logger

To download data from the logger:

  1. Tap Devices. Press the Start/Stop button on the logger to wake it up, if necessary. Tap the logger tile in the app to connect to the logger.
  2. Tap Download Data. The logger downloads data to the phone, tablet, or computer.
  3. Once the download is complete, tap Done to return to the previous page or tap Export and Share to save the file in the specified format.
  4. When the export file has successfully been created, tap Done to return to the previous page or tap Share to use your device's usual modes of sharing.

You can also upload data automatically to HOBOlink, Onset's web-based software, using the app or the MX gateway. For details, see the HOBOconnect User Guide and see the HOBOlink help for details on working with data in HOBOlink.

Logger Events

The logger records the following internal events to track logger operation and status. You can view events in exported files or plot events in the app.

Internal Event NameDefinition
Host ConnectedThe logger was connected to the mobile device.
StartedThe Start/Stop button was pressed to begin or resume logging.
StoppedThe logger received a command to stop recording data (from the app or by pushing the Start/Stop button).
Button Up/Button DownThe Start/Stop button was pressed for 1 second.
Chan <#> Alarm TrippedA sensor alarm has tripped; <#> is the sensor number, where 1 is temperature and 2 is RH.
Chan <#> Alarm ClearedA sensor alarm has cleared; <#> is the sensor number, where 1 is temperature and 2 is RH. This event also contains the value that was furthest out of range for the sensor before the alarm cleared, which is only available in a shared or exported file.
New IntervalThe logger has entered or exited burst logging mode.
Safe ShutdownThe battery level dropped below 1.85 V; the logger performs a safe shutdown.

Mounting the Logger

There are several ways to mount the logger using the materials included:

Protecting the Logger

The logger is designed for indoor use and can be permanently damaged by corrosion if it gets wet. Protect it from condensation. If the message FAIL CLK appears on the LCD screen, there was a failure with the internal logger clock possibly due to condensation. Remove the battery immediately and dry the circuit board.

Note: Static electricity may cause the logger to stop logging. The logger has been tested to 8 KV, but avoid electrostatic discharge by grounding yourself to protect the logger. For more information, search for "static discharge" on onsetcomp.com.

Battery Information

The logger requires two user-replaceable AAA 1.5 V alkaline or optional lithium batteries for operation at the extreme ends of the logger operating range. Expected battery life varies based on the ambient temperature where the logger is deployed, the logging or sampling interval, frequency of offloading and connection to the mobile device, number of channels that are active, audible alarms duration, use of burst mode or statistics logging, and battery performance. New batteries typically last 1 year with logging intervals greater than 1 minute. Deployments in extremely cold or hot temperatures, a logging interval faster than 1 minute, or a sampling interval faster than 15 seconds can impact battery life. Estimates are not guaranteed due to uncertainties in initial battery conditions and operating environment.

Note: Make sure the batteries installed have flat negative terminals. There should be no indent in the bottom of the batteries. Batteries with indents in the negative terminals may become loose and prevent proper operation.

To install or replace the batteries:

  1. Open the battery door on the back of the logger.
  2. Remove any old batteries.
  3. Insert two new batteries observing polarity.
  4. Reinsert the battery door and snap it back into place.

WARNING: Do not cut open, incinerate, heat above 85°C (185°F), or recharge the lithium batteries. The batteries may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery case. Do not dispose of the logger or batteries in fire. Do not expose the contents of the batteries to water. Dispose of the batteries according to local regulations for lithium batteries.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

Industry Canada Statements

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Avis de conformité pour l'Industrie Canada

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

To comply with FCC and Industry Canada RF radiation exposure limits for general population, the HOBO MX1101 loggers must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

NCC Statement

經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。

低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作 業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

Translation:

Article 12

Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to an approved low power radio-frequency device.

Article 14

The low power radio-frequency devices shall not influence aircraft security and interfere with legal communications. If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.

PDF preview unavailable. Download the PDF instead.

17840-U MX1101 Manual Acrobat Distiller 22.0 (Windows)

Related Documents

Preview HOBO MX2300 Series Data Logger Manual: Temperature & RH Monitoring
Comprehensive manual for the HOBO MX2300 Series Bluetooth Low Energy (BLE) data loggers by Onset. Covers setup, specifications, operation, and data analysis for temperature and relative humidity monitoring.
Preview HOBO MX2205 TidbiT Ext Temp Logger Manual - Temperature Monitoring Guide
Comprehensive user manual for the HOBO MX2205 TidbiT Ext Temp Logger, detailing specifications, setup, configuration, data logging, and maintenance for environmental temperature monitoring.
Preview HOBO MX1104 & MX1105 Data Logger Quick Start Guide | Onset
Quick start guide for Onset HOBO MX1104 (Analog/Temp/RH/Light) and MX1105 (4-Channel Analog) data loggers. Learn how to download HOBOconnect, connect your logger, configure settings, and download data.
Preview HOBO MX1104 & MX1105 Data Logger Quick Start Guide
Concise guide to setting up, deploying, and offloading data from HOBO Analog/Temp/RH/Light (MX1104) and 4-Channel Analog (MX1105) data loggers using the HOBOconnect app.
Preview HOBO MX2300 Series Data Logger Quick Start Guide | Onset Computer Corporation
Quick Start Guide for the HOBO MX2300 Series Data Loggers by Onset Computer Corporation. Learn how to download the HOBOconnect app, connect your logger, configure settings, start logging, and offload data. Includes important safety warnings and contact information.
Preview HOBO MX801 Submersible Logger Quick Start Guide
A quick start guide for the HOBO MX801 Submersible Logger, detailing setup, configuration, deployment, data download, and processing for water parameter logging using HOBOconnect.
Preview HOBO U12 4-External Channel Outdoor/Industrial Logger Manual
This manual provides comprehensive instructions for the HOBO U12 4-External Channel Outdoor/Industrial Data Logger (U12-008), covering its features, specifications, setup, operation, and maintenance.
Preview HOBO Pro v2 Logger (U23-00x) Quick Start Guide
This guide provides essential steps for setting up and deploying the HOBO Pro v2 Logger (U23-00x) series. It covers software installation, connecting the logger via base station or shuttle, deployment best practices including solar radiation shielding and cable management, and data readout procedures. Learn how to ensure accurate environmental data collection with your HOBO logger.