Schneider Electric Osiconcept Photo-electric Sensors
This document provides installation and troubleshooting information for Schneider Electric Osiconcept photo-electric sensors, including the XUB, XUM, XUK, and XUX series.
Troubleshooting Guide
Status | Diagnostic | Causes | Actions |
---|---|---|---|
Green | Init mode or press <3s | Press > 3 s | |
Red | Environment is incorrect | Range limit (Reflex, obstacle) | Review the alignment conditions + restart learning (press > 3 s) |
Red | Alignment is incorrect Setting limit | Range limit | Review the setting |
Red | Fine setting failed | Object is absent | Position the object or reset (press > 9 s) |
Off limit | Fine setting failed | Object is too clear | Reset (press > 9 s) |
Fine EFFAR setting failed | Too close to background | Reset (press > 9 s) | |
Red | Fine direct REFLEX setting failed (Proxi) | Insufficient threshold level "Lens polluted" | Reset (press > 9 s) |
Red | Clogging | Optical cleaning; preventive maintenance |
Operation and Wiring
The document details various sensing modes including Diffuse/Proximity, Background Suppression, Polarized Reflex, and Thru-beam.
- Sensing Modes: A (Diffuse/Proximity), B (Background Suppression), C (Polarized Reflex), D (Thru-beam).
- Alignment: Standard setting and fine object setting procedures are described.
- Output Inversion: Instructions for inverting the output signal (NO/NC) are provided.
- Reset: Procedure for resetting the sensor.
- Display Mode: Information on how to visualize the sensor's operating mode.
Product Series and Connectors
- XUB Series: Available in M18x64 size.
- XUM Series: Available in 12x34x20 size.
- XUK Series: Available in 18x50x50 size.
- XUX Series: Available in 30x92x71 size.
- Connectors: Details for M12 and M8 connectors, including PNP/NPN configurations and relay outputs.
- Transmitter for Thru-beam: Specific information for the transmitter component in thru-beam applications.
- Terminal Block Versions: Information for XUX terminal block T16 version.
Wiring Diagrams and Options
- PNP/NPN Wiring: Diagrams illustrating PNP and NPN output configurations.
- Relay Output Wiring: Diagrams for relay output connections.
- Options: Details on time delay and one-shot functions for XUK and XUX series, including diagrams for ON DELAY, OFF DELAY, and ONE SHOT modes.
Safety Information
DANGER: Hazard of electric shock, explosion, or arc flash. Disconnect all power before servicing equipment. Failure to follow these instructions will result in death or serious injury.
WARNING: Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. Schneider Electric assumes no responsibility for consequences arising from the use of this material.