XUK0ARCTL2 Photo-electric Sensor

Product Type: Photo-electric sensor

Series: OsiSense XU

Model: XUK0ARCTL2

Description: Multi-mode, compact 50x50 sensor with 2m cable, suitable for general purpose applications.

Main Characteristics

Commercial StatusCommercialised
Range of productOsiSense XU
Series nameGeneral purpose multimode
Electronic sensor typePhoto-electric sensor
Sensor nameXUK
Sensor designCompact 50 x 50
Detection systemMultimode
MaterialPlastic
Type of output signalDiscrete
Supply circuit typeAC/DC
Wiring technique5-wire
Discrete output function1 NO or 1 NC programmable
Electrical connectionCable
Cable length2 m
Product specific application-
Emission
  • Red polarised reflex
  • Infrared thru beam
  • Infrared diffuse with background suppression
  • Infrared diffuse
[Sn] nominal sensing distance
  • 30 m thru beam (requires transmitter XUK0ARCTL2T)
  • 4 m polarised reflex (requires reflector XUZC50)
  • 0.8 m diffuse
  • 0.28 m diffuse with background suppression

Complementary Characteristics

Enclosure materialPBT
Lens materialPMMA
Maximum sensing distance
  • 5.7 m polarised reflex
  • 1.2 m diffuse
  • 0.28 m diffuse with background suppression
  • 35 m thru beam
Output typeRelay
Add on outputWithout, <= 50 mA with overload and short-circuit protection
Wire insulation materialPvR
Status LED
  • 1 LED (yellow) for output state
  • 1 LED (red) for instability
  • 1 LED (green) for supply
[Us] rated supply voltage
  • 24...240 V DC
  • 24...240 V AC
Supply voltage limits
  • 20...264 V DC
  • 20...264 V AC
Switching capacity in mA3 A (power factor = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V)
Switching frequency<= 20 Hz
Voltage drop<= 1.5 V (closed state)
Power consumption in W3 W AC/DC
Time delay range0...10 s monostable, on-delay or off-delay (programmable) delay
Delay first up< 300 ms
Delay response< 25 ms
Delay recovery< 25 ms
Setting-upSelf-teaching

Electrical Characteristics

Electrical durability500000 cycles, power factor = 1, 60 cycles/minute at 250 V
Depth18 mm
Height50 mm
Width50 mm
Product weight0.175 kg

Environment and Certifications

Product certifications
  • CE
  • CSA
  • UL
Ambient air temperature for operation-25...55 degrees Celsius
Ambient air temperature for storage-40...70 degrees Celsius
Vibration resistance7 g-force, amplitude = plus or minus 1.5 mm (frequency = 10...55 Hz) conforming to IEC 60068-2-6
Shock resistance30 g-force (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protectionIP65 double insulation conforming to IEC 60529

Compliance and Warranty

RoHS complianceCompliant
RoHS EUR statusCompliant
RoHS EUR conformity date(YYWW)0903
Contractual warranty period18 months

Disclaimer

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

PDF preview unavailable. Download the PDF instead.

tele xuk0arctl2 datasheet

Related Documents

Preview Schneider Electric XUK1ARCNL5 Photoelectric Sensor Data Sheet
Technical specifications and characteristics for the Schneider Electric XUK1ARCNL5 photoelectric sensor. Details include sensing distance, output type, electrical specifications, environmental ratings, and packaging information.
Preview Schneider Electric Osiconcept Photoelectric Sensors: Installation and Troubleshooting Guide
Comprehensive guide for Schneider Electric Osiconcept photo-electric sensors (XUB, XUM, XUK, XUX series), covering installation, operation, troubleshooting, and technical specifications. Includes troubleshooting tables and wiring diagrams.
Preview Wiser Temperature/Humidity Sensor User Guide
User guide for the Schneider Electric Wiser Temperature/Humidity Sensor, covering installation, pairing, configuration, usage, automation creation, troubleshooting, and technical specifications.
Preview Schneider Electric SpaceLogic Sensors Installation Guide: Humidity and Temperature
Installation instructions and specifications for Schneider Electric's SpaceLogic SLA Series humidity and temperature sensors, covering product features, wiring, setup, and operation for building automation systems.
Preview Schneider Electric Ceiling Mounted Ultrasonic Occupancy Sensor Instruction Bulletin
Instruction bulletin detailing the features, specifications, installation, and operation of Schneider Electric's SLSCUS series ceiling-mounted ultrasonic occupancy sensors, including models SLSCUS501, SLSCUS1001, SLSCUS2001, and SLSCUS801.
Preview Schneider Electric Easergy CL110 Installation and Operation Manual
Comprehensive guide for installing and operating the Schneider Electric Easergy CL110 wireless thermal and humidity sensor. Covers safety precautions, general description, installation steps, pairing procedures, operating modes, maintenance, troubleshooting, environmental impacts, and technical specifications.
Preview Schneider Electric SmartX Living Space Resistive Temperature Sensor SXWSATXXXRXX Installation Instructions
Comprehensive installation guide for the Schneider Electric SmartX Living Space Resistive Temperature Sensor (SXWSATXXXRXX). Covers product description, features, specifications, system architecture, safety precautions, and installation steps.
Preview Modicon M172 Display Color TouchScreen, Temperature & Humidity Built-in Sensors Datasheet
Product data sheet for the Modicon M172 Display Color TouchScreen, Temperature & Humidity built-in sensors. Includes specifications, ordering and shipping details, and environmental data.