Z-Wave Protocol Implementation Conformance Statement

Indoor Siren 6

General Information

Product Identifier:ZW164-B
Brand Name:Aeotec
Product Version:HW: 164 FW: 1.04
Z-Wave Certification #:ZC10-19046419

Product Features

Firmware UpdatableUpdatable by Consumer by RF
Outdoor UseNo
Supported Notification TypesHome Security, Power Management, Siren
SensorsVibration/Shock (Binary)
ColorWhite

Z-Wave Product Information

Supports Z-Wave Beaming Technology?Yes
Supports Z-Wave Network Security?Yes
Supports Z-Wave AES-128 Security S0?Yes
Supports Security S2?Yes: S2 Authenticated, S2 Unauthenticated
SmartStart Compatible?No

Z-Wave Technical Information

Z-Wave Frequency:Australia / New Zealand
Z-Wave Product ID:0x00A4
Z-Wave Product Type:0x0203
Z-Wave Hardware Platform:ZM5101
Z-Wave Development Kit Version:6.71.03
Z-Wave Library Type:Enhanced 232 Slave

Association Group Information

Group # / Max NodesDescription
1/5Lifeline group. (1) Device Reset Locally Notification, issued when Factory Reset is performed. (2) Sound Switch Tone Play Report, issued when a tone has started playing. (3) Sound Switch Configuration Report, issued when volume or default tone has changed. (4) Notification Report (Type=0x0E; Event=0x01), issued when Chime starts playing tone. (5) Notification Report (Type=0x0E; Event=0x00), issued when Chime stops playing tone. (6) Notification Report (Type=0x07; Event=0x09), issued when Chime is tampered and moved. (7) Notification Report (Type=0x08; Event=0x0A), issued when Button is low battery. (8) Notification Report (Type=0x08; Event=0x00), issued when Button comes back to normal battery. (9) Configuration Report (Parameter=0x32), issued when Pairing Button Mode is triggered. (10) Configuration Report (Parameter=0x33), issued when Unpairing or Pairing Button Mode finishes.
2/5Mirror of Endpoint 1, group 2. When Endpoint 1 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
3/5Mirror of Endpoint 2, group 2. When Endpoint 2 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
4/5Mirror of Endpoint 3, group 2. When Endpoint 3 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
5/5Mirror of Endpoint 4, group 2. When Endpoint 4 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
6/5Mirror of Endpoint 5, group 2. When Endpoint 5 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
7/5Mirror of Endpoint 6, group 2. When Endpoint 6 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
8/5Mirror of Endpoint 7, group 2. When Endpoint 7 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.
9/5Mirror of Endpoint 8, group 2. When Endpoint 8 starts playing tone or stops playing tone, Nodes associated are controlled and will receive a Basic Set CC.

Supported Command Classes (18):

Controlled Command Classes (1):

PDF preview unavailable. Download the PDF instead.

pics?noFilename=True PDFjet v3.03 (http://pdfjet.com)

Related Documents

Preview Aeotec Smart Switch 6 Z-Wave Protocol Implementation Conformance Statement
This document details the Z-Wave protocol implementation conformance statement for the Aeotec Smart Switch 6, including general information, product features, Z-Wave product information, and technical details.
Preview Aeotec Nano Shutter Z-Wave Conformance Statement
This document details the Z-Wave Protocol Implementation Conformance Statement for the Aeotec Nano Shutter, including general information, product features, Z-Wave product information, technical specifications, and supported command classes.
Preview Aeotec Smart Dimmer 6 Z-Wave Conformance Statement
This document details the Z-Wave protocol implementation conformance statement for the Aeotec Smart Dimmer 6, including general information, product features, Z-Wave product information, technical specifications, and association group information.
Preview Aeotec WallMote Z-Wave Protocol Implementation Conformance Statement
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Aeotec WallMote (ZW129-A), detailing its features, technical specifications, and supported command classes.
Preview Aeotec Door/Window Sensor Gen5 Z-Wave Conformance Statement
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Aeotec Door/Window Sensor Gen5, detailing its technical specifications, supported features, and Z-Wave network information.
Preview Aeotec Doorbell Gen5 Z-Wave Protocol Implementation Conformance Statement
This document provides the Z-Wave Protocol Implementation Conformance Statement for the Aeotec Doorbell Gen5, detailing its technical specifications, product information, and association group configurations.
Preview Aeotec Dual Nano Switch Z-Wave Conformance Statement
Official Z-Wave Protocol Implementation Conformance Statement for the Aeotec Dual Nano Switch, detailing technical specifications, product features, and association group information.
Preview Z-Wave LED Strip Protocol Implementation Conformance Statement
This document outlines the Z-Wave protocol implementation conformance statement for the Aeotec LED Strip, model ZW121-A. It details product information, features, and technical specifications related to Z-Wave connectivity.