Cooper & Hunter Vital 2 Series Air Conditioners
Model Series: Vital 2
Brand: Cooper & Hunter
Website: www.cooperhunter.pl
Warranty: 5 Years
Specifications Overview
The Vital Inverter 2 is a modern and stylish 6th generation air conditioning unit. Its minimalist white panel, compact dimensions, and a range of applied proven solutions ensure that air conditioners from this series can discreetly provide comfort in any room.
Operating Temperature Ranges:
- Cooling: -15°C to +43°C
- Heating: -15°C to +24°C
Key Functions
Control
Standard Control: Includes a wireless remote control (Model: YAP1F).
[Image of a white remote control with buttons labeled ON/OFF, TECHNOLOGY, etc.]
Technical Data
The Vital 2 series offers several models with varying capacities and specifications:
Indoor Unit Specifications
Model | CH-S09FTXF2-NG | CH-S12FTXF2-NG | CH-S18FTXF2-NG | CH-S24FTXF2-NG |
---|---|---|---|---|
Power Supply (V-Hz/phase) | 220-240~50/1 | 220-240~50/1 | 220-240~50/1 | 220-240~50/1 |
Nominal Capacity (kW) | 2.70 | 3.20 | 4.60 | 6.20 |
Power Consumption Nominal (W) | 725 | 991 | 1355 | 1827 |
Operating Current (A) | 3.45 | 4.40 | 5.90 | 7.60 |
Cooling EER (W/W) | 3.72 | 3.23 | 3.39 | 3.40 |
Annual Energy Consumption Cooling (kWh/year) | 139 | 184 | 251 | 319 |
Cooling SEER (W/W) | 6.80 | 6.10 | 6.40 | 6.80 |
Energy Class Cooling | A++ | A++ | A++ | A++ |
Nominal Capacity Heating (kW) | 2.80 | 3.40 | 5.20 | 6.50 |
Power Consumption Nominal Heating (W) | 685 | 916 | 1340 | 1912 |
Operating Current Heating (A) | 3.19 | 4.00 | 5.80 | 7.60 |
Heating COP (W/W) | 4.09 | 3.71 | 3.88 | 3.40 |
Annual Energy Consumption Heating (kWh/year) | 867 | 945 | 1295 | 1645 |
Heating SCOP (W/W) | 4.20 | 4.00 | 4.00 | 4.00 |
Energy Class Heating | A+ | A+ | A+ | A+ |
Wi-Fi Communication | + | + | + | + |
Dimensions (W x D x H) (mm) | 773x185x250 | 773x185x250 | 970x225x300 | 970x225x300 |
Transport Dimensions (W x D x H) (mm) | 817x244x306 | 817x244x306 | 1017x285x366 | 1017x285x366 |
Net/Gross Weight (kg) | 8.5/9.5 | 8.5/9.5 | 13.5/16.0 | 13.5/16.0 |
Dehumidification Capacity (l/h) | 0.80 | 1.40 | 1.80 | 1.80 |
Airflow (m³/h) | 280/310/340/400/480/520/550 | 280/320/350/400/480/520/590 | 400/600/800/850 | 400/600/800/900 |
Sound Pressure Level Cooling (dB(A)) | 21/26/29/33/35/37/40 | 24/26/30/33/35/37/41 | 31/38/42/44 | 30/37/45/48 |
Sound Pressure Level Heating (dB(A)) | 24/26/30/33/35/37/40 | 25/28/31/33/35/37/41 | 34/41/46/48 | 26/37/45/48 |
Outdoor Unit Specifications
Model | CH-S09FTXF2-NG | CH-S12FTXF2-NG | CH-S18FTXF2-NG | CH-S24FTXF2-NG |
---|---|---|---|---|
Dimensions (W x D x H) (mm) | 732x330x555 | 732x330x555 | 732x330x555 | 873x376x555 |
Transport Dimensions (W x D x H) (mm) | 791x373x590 | 791x373x590 | 791x373x590 | 948x428x591 |
Net/Gross Weight (kg) | 24.5/27.0 | 25.0/27.5 | 26.5/29.0 | 36.5/39.5 |
Airflow (m³/h) | 1950 | 1950 | 1950 | 3200 |
EEV/Capillary | capillary | capillary | capillary | capillary |
Sound Pressure Level (dB(A)) | 51 | 52 | 55 | 57 |
Liquid/Gas Pipe Size (mm/inch) | Ø6.35/9.52 (1/4"/3/8") | Ø6.35/9.52 (1/4"/3/8") | Ø6.35/9.52 (1/4"/3/8") | Ø6.35/12.70 (1/4"/1/2") |
Refrigerant Charge (kg) | 0.50 | 0.55 | 0.75 | 1.23 |
Additional Refrigerant Charge (g/m) | 16 | 20 | 16 | 16 |
Refrigerant Pipes - Standard Installation Length (m) | 5 | 5 | 5 | 5 |
Refrigerant Pipes - Max Installation Length (m) | 15 | 20 | 25 | 25 |
Refrigerant Pipes - Max Height Difference (m) | 10 | 10 | 10 | 10 |
Power Supply Unit/Cross-section (N x mm²) | Outdoor / 3x2.5 | Outdoor / 3x2.5 | Outdoor / 3x2.5 | Outdoor / 3x2.5 |
Recommended Electrical Wires & Protection (N x mm²) | 4x1.0 | 4x1.0 | 4x1.5 | 4x1.5 |
Recommended Electrical Wires & Protection (A) | 10 | 10 | 16 | 16 |
Outdoor Unit Operating Temp. Cooling (°C) | -15~43 | -15~43 | -15-43 | -15-43 |
Outdoor Unit Operating Temp. Heating (°C) | -15~24 | -15~24 | -15~24 | -15~24 |
Diagrams
[Diagram of the indoor unit showing dimensions: A (width) 773mm, B (height) 250mm, C (depth) 185mm for CH-S09FTXF2-NG/CH-S12FTXF2-NG; A (width) 970mm, B (height) 300mm, C (depth) 225mm for CH-S18FTXF2-NG/CH-S24FTXF2-NG.]
[Diagram of the outdoor unit showing dimensions: For CH-S09FTXF2-NG/CH-S12FTXF2-NG/CH-S18FTXF2-NG: A (width) 675mm, B (height) 732mm, C (depth) 555mm, D (width) 285mm, E (height) 330mm, F (depth) 455mm, G (width) 310mm. For CH-S24FTXF2-NG: A (width) 805mm, B (height) 873mm, C (depth) 555mm, D (width) 317mm, E (height) 376mm, F (depth) 528mm, G (width) 349mm.]