Siemens SIMATIC S7-1200
Digital I/O Module
Model: 6ES7223-1BL32-0XB0
Description: SIMATIC S7-1200, Digital I/O SM 1223, 16 DI/16 DO, 16 DI 24 V DC, Sink/Source, 16 DO, transistor 0.5 A
Figure similar
General Information
Product Type Designation | SM 1223, DI 16x24 V DC, DQ 16x24 V DC |
---|
Supply Voltage
Rated Value (DC) | 24 V |
---|---|
Permissible Range, Lower Limit (DC) | 20.4 V |
Permissible Range, Upper Limit (DC) | 28.8 V |
Input Current
From Backplane Bus 5 V DC, max. | 185 mA |
---|
Digital Inputs
From Load Voltage L+ (without load), max. | 4 mA; per channel |
---|---|
Supply Voltage of the Transmitters / Header | Yes |
Power Loss, typ. | 4.5 W |
Number of Digital Inputs | 16 |
In Groups Of | 2 |
Input Characteristic Curve | In accordance with IEC 61131, type 1 |
Number of Simultaneously Controllable Inputs | 16 |
All Mounting Positions (up to 40 °C, max.) | 16 |
Horizontal Installation (up to 40 °C, max.) | 16 |
Horizontal Installation (up to 50 °C, max.) | 16 |
Vertical Installation (up to 40 °C, max.) | 16 |
Type of Input Voltage | DC |
Rated Value (DC) | 24 V |
For Signal "0" | 5 V DC at 1 mA |
For Signal "1" | 15 V DC at 2.5 mA |
Input Current for Signal "0", max. (permissible quiescent current) | 1 mA |
Input Current for Signal "1", min. | 2.5 mA |
Input Current for Signal "1", typ. | 4 mA |
Input Delay (for rated value of input voltage) | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four for interrupt inputs. |
Cable Length
Shielded, max. | 500 m |
---|---|
Unshielded, max. | 300 m |
Digital Outputs
Number of Digital Outputs | 16 |
---|---|
In Groups Of | 1 |
Short-Circuit Protection | No; to be provided externally |
Limitation of Inductive Shutdown Voltage To | L+ (-48 V) |
Switching Capacity of the Outputs (with resistive load, max.) | 0.5 A |
Switching Capacity of the Outputs (on lamp load, max.) | 5 W |
Output Voltage Rated Value (DC) | 24 V |
Output Voltage for Signal "0", max. | 0.1 V; with 10 kOhm load |
Output Voltage for Signal "1", min. | 20 V DC |
Output Current for Signal "1" Rated Value | 0.5 A |
Output Current for Signal "1" Permissible Range, max. | 0.5 A |
Output Current for Signal "0" Residual Current, max. | 10 µA |
Output Delay with Resistive Load ("0" to "1", max.) | 50 µs |
Output Delay with Resistive Load ("1" to "0", max.) | 200 µs |
Total Current of the Outputs (per group) Horizontal Installation (up to 50 °C, max.) | 8 A; Current per mass |
Relay Outputs
Switching Capacity of Contacts (with inductive load, max.) | 0.5 A |
---|---|
Switching Capacity of Contacts (on lamp load, max.) | 5 W |
Switching Capacity of Contacts (with resistive load, max.) | 0.5 A |
Cable Length Shielded, max. | 500 m |
Cable Length Unshielded, max. | 150 m |
Interrupts/Diagnostics/Status Information
Alarms: Diagnostic Alarm | Yes |
---|---|
Diagnostics Indication LED: For Status of the Inputs | Yes |
Diagnostics Indication LED: For Status of the Outputs | Yes |
Potential Separation
Potential Separation Digital Inputs: Between the Channels, in Groups of | 2 |
---|---|
Potential Separation Digital Outputs: Between the Channels, in Groups of | 1 |
Potential Separation Digital Outputs: Between the Channels and Backplane Bus | 500 V AC |
Degree and Class of Protection
IP Degree of Protection | IP20 |
---|
Standards, Approvals, Certificates
CE Mark | Yes |
---|---|
CSA Approval | Yes |
UL Approval | Yes |
cULus | Yes |
FM Approval | Yes |
RCM (formerly C-TICK) | Yes |
KC Approval | Yes |
Marine Approval | Yes |
Ecological Footprint | Yes |
Environmental Conditions
Global Warming Potential
Global Warming Potential, (Total) [CO2 eq] | 123 kg |
---|---|
Global Warming Potential, (During Production) [CO2 eq] | 12.1 kg |
Global Warming Potential, (During Operation) [CO2 eq] | 111 kg |
Global Warming Potential, (After End of Life Cycle) [CO2 eq] | -0.434 kg |
Ambient Conditions
Free Fall: Fall Height, max. | 0.3 m; five times, in product package |
---|---|
Ambient Temperature During Operation: Min. | -20 °C |
Ambient Temperature During Operation: Max. | 60 °C |
Ambient Temperature During Operation: Horizontal Installation, Min. | -20 °C |
Ambient Temperature During Operation: Horizontal Installation, Max. | 60 °C |
Ambient Temperature During Operation: Vertical Installation, Min. | -20 °C |
Ambient Temperature During Operation: Vertical Installation, Max. | 50 °C |
Permissible Temperature Change | 5 °C to 55 °C, 3 °C / minute |
Ambient Temperature During Storage/Transportation: Min. | -40 °C |
Ambient Temperature During Storage/Transportation: Max. | 70 °C |
Air Pressure acc. to IEC 60068-2-13: Storage/Transport, Min. | 660 hPa |
Air Pressure acc. to IEC 60068-2-13: Storage/Transport, Max. | 1 080 hPa |
Relative Humidity: Operation at 25 °C without condensation, max. | 95 % |
Connection Method & Mechanics/Material
Connection Method: Required Front Connector | Yes |
---|---|
Mechanics/Material: Enclosure Material (Front) | Plastic |
Dimensions & Weight
Width | 70 mm |
---|---|
Height | 100 mm |
Depth | 75 mm |
Weight, approx. | 310 g |
Classifications
eClass
Version | Classification |
---|---|
14 | 27-24-22-04 |
12 | 27-24-22-04 |
9.1 | 27-24-22-04 |
9 | 27-24-22-04 |
8 | 27-24-22-04 |
7.1 | 27-24-22-04 |
6 | 27-24-22-04 |
ETIM
Version | Classification |
---|---|
10 | EC001419 |
9 | EC001419 |
8 | EC001419 |
7 | EC001419 |
IDEA
Version | Classification |
---|---|
4 | 3566 |
UNSPSC
Version | Classification |
---|---|
15 | 32-15-17-05 |
Approvals / Certificates
General Product Approval:
- KC (Korean Certification)
- RCM (Regulatory Compliance Mark, formerly C-TICK)
- UL (Underwriters Laboratories)
- FM (Factory Mutual)
- CCC-Ex (China Compulsory Certification for Explosion Protection)
- ATEX (Atmosphères Explosibles)
- IECE (International Electrotechnical Commission System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres)
- ABS (American Bureau of Shipping)
- Bureau Veritas
- DNV (Det Norske Veritas)
- Lloyd's Register
- NK / Nippon Kaiji Kyokai (Nippon Kaiji Kyokai)
- RINA (Registro Italiano Navale)
- RMRS (Russian Maritime Register of Shipping)
- CCS (China Classification Society)
- KR (Korean Register of Shipping)
- EPD (Environmental Product Declaration)