SIMATIC S7-1200 Update to the S7-1200 System Manual, edition 01/2015 Product Information Overview to Documentation Update S7-1200 In spite of efforts to ensure the accuracy and clarity in the product documentation, some of the pages in the S7-1200 Programmable Controller System Manual contain information that has been identified as being incomplete, incorrect or misleading. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens' products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. You can find more information about industrial security on the Internet (http://www.siemens.com/industrialsecurity). To stay informed about product updates as they occur, sign up for a product-specific newsletter. You can find more information on the Internet (http://support.automation.siemens.com). This document contains the following updates Setting the maximum record length for some Profibus communication instructions (Page 2) Error condition with GEO2LOG (Page 2) RS485/RS422 connector pin assignments (Page 2) Potential problems with performing a firmware update from the Web server (Page 3) Correction of CPU 1211C DC/DC/Relay input current specification (Page 3) Inability to write floating point values from the Web server (Page 3) CM 1241 V2.1 firmware required for Point-to-Point, Modbus RTU, and USS library instructions (Page 6) Use of the DPRD_DAT and DPWR_DAT instructions to access consistent data (Page 6) CE approval - EC Directive 94/9/EC (ATEX) update (Page 7) Wiring rules (Page 7) Correction of terminal block spare kits ordering information (Page 8) SM 1231, SM 1234, and SB 1231 wiring current transducers (Page 9) © Siemens AG 2015. All rights reserved A5E03666852-AB, 03/2015 1 Setting the maximum record length for some Profibus communication instructions When using a CM1243-5 Profibus Master module to control an ET200SP or ET200MP Profibus device that uses a RS232, RS422, or RS485 point-to-point module, you need to explicitly set the "max_record_len" data block tag to 240 for some communication instructions as defined below: Instruction Send_P2P Modbus_Master Modbus_Slave Limitation Set "max_record_len" in the instance DB (for example, "Send_P2P_DB".max_record_len) to 240 after running any configuration instruction such as Port_Config, Send_Config, or Receive_Config. Set "max_record_len" in the Send_P2P section of the instance DB (for example, "Modbus_Master_DB".Send_P2P.max_record_len to 240 after running Modbus_Comm_Load. Set "max_record_len" in the Send_P2P section of the instance DB (for example, "Modbus_Slave_DB".Send_P2P.max_record_len to 240 after running Modbus_Comm_Load. Explicitly assigning max_record_len is only necessary with Profibus communication; Profinet communication already uses a valid max_record_len value. Error condition with GEO2LOG The GEO2LOG address returns error 16#8095 when the program uses it to attempt to obtain the address of a configured signal module. You cannot use GEO2LOG to obtain addresses of central (local rack) I/O modules, but you can use it to obtain addresses of distributed I/O modules. RS485/RS422 connector pin assignments Table A-257 describes the pins of the RS485/RS422 connector. This update to that table provides updated information about the pin assignments: Table 1 RS485 or RS422 connector (female) Pin Description Connector Pin (female) Description 1 2 TxD+ 1 3 TxD+2 4 RTS3 Logic or communication ground Connected for RS422 Not used for RS485: Output Signal B (RxD/TxD+): Input/Output Request to send (TTL level) Output 6 PWR 7 +5 V with 100 ohm series resistor: Output Not connected 8 TXD-2 9 TXD- 1 Signal A (RxD/TxD-): Input/Output Connected for RS422 Not used for RS485: Output 5 GND Logic or communication ground SHELL Chassis ground 1 Pin 2 (TxD+) and Pin 9 (TxD-) are the RS422 transmit signals. 2 Pin 3 (RxD/Tx+) and Pin 8 (RxD/TxD-) are RS485 transmit and receive signals. For RS422, Pin 3 is RxD+ and Pin 8 is RxD-. 3 The RTS is a TTL level signal and can be used to control another half duplex device based on this signal. It is active when you transmit and is inactive all other times. Update to the S7-1200 System Manual, edition 01/2015 2 A5E03666852-AB, 03/2015 Potential problems with performing a firmware update from the Web server In the event of a communications disruption during a firmware update from the Web server, your Web browser could display a message asking whether you want to leave or stay on the current page. To avoid potential problems, select the option to stay on the current page. If you close the Web browser while in the process of performing a firmware update from the Web server, you will be unable to change the operating mode of the CPU to RUN mode. If this situation happens, you must cycle power to the CPU to be able to change the CPU to RUN mode. Correction of CPU 1211C DC/DC/Relay input current specification The Power Supply table (Table A-15) is incorrect. The input current for the CPU only at max. load for the CPU 1211C DC/DC/Relay is 300 mA at 24 VDC (not 30 mA at 24 VDC). Inability to write floating point values from the Web server The Web server cannot write floating point values such as 3.5 to PLC tags or data block tags of type Real or LReal from either the Variable Status standard Web page or from a user-defined Web page. If you want to write a floating point value to a Real or LReal tag or data block tag, or to a memory address, you have the following alternatives: For PLC tags and standard (non-optimized) data block tags of type Real, you can use the Variable Status page to modify the value by its direct memory address rather than by the tag name. You cannot modify LReals from the Variable Status page using a memory address. Use integer tags for the Web server input, and use floating point math in the STEP 7 program to convert the number to the desired degree of accuracy. Write the Hexadecimal or binary representation of an IEEE 754 floating point number to the floating point tag or memory location. This method is only available for data entry from the Variable Status standard Web page. User-defined Web pages are not able to write binary or Hexadecimal data values to floating point tags. Modifying Real tags through memory addresses On the Variable Status standard Web page, you can enter the address of a Real tag from the PLC tag table or from a nonoptimized data block, for example, MD0 or DB1.DBD0. Data block addresses contain the DB number and the offset within the data block, which you can find in STEP 7. You can then use the FLOATING_POINT display type to modify the memory corresponding to the Real tag. You cannot modify LReal tags by memory address. Converting integer Web server data entry to floating point values Because the Web server cannot write floating point values to the PLC, you could create integer tags (for example, UInt, SInt, DInt) in your STEP 7 program for the purpose of accepting data entry from the Web server. Based on your desired degree of accuracy, your integer tags could represent 10x, 100x, 1000x or some other multiple of 10 of your actual floating point value. For example, if you are expecting floating point values to three decimal points of accuracy, you could accept data entry from operators with a multiplier of 1000 and then perform a division by 1000.0 in the STEP 7 user program. You could declare tags such as the following in a PLC tag table, or in a data block: From the Variable Status page or from a user-defined Web page, operators would then enter an integer value for the Valuex1000 tag. For example, if the floating point value to be entered is 45.678, the operator would enter 45678 for the Valuex1000 tag. Update to the S7-1200 System Manual, edition 01/2015 A5E03666852-AB, 03/2015 3 The STEP 7 program would then include logic to produce the desired floating point value from the entered integer value, for example: Of course, the STEP 7 program would need to perform appropriate range checking. Converting a floating point number to Hexadecimal The S7-1200 stores floating point numbers in IEEE 754 format. This format consists of a sign bit, a "biased" exponent for the power of 2, and the mantissa using the following formula: <sign> 2 exponent * mantissa The Real data type uses 32 bits and LReal uses 64 bits. The allocation of the bits to the sign, exponent, and mantissa for both data types are as follows: Figure 1 Real number 32-bit representation in IEEE 754 format Figure 2 LReal number 64-bit representation in IEEE 754 format To convert a floating point number to a Hexadecimal value, follow these steps: 1. Convert your Base 10 floating point number to Base 2 (binary). For example, 3.510 = 11.12 (2 + 1 + 1/2) 2. Normalize the resulting value to have a single digit to the left of the binary point by multiplying by the appropriate power of 2: 11.12 = 1.11 * 21 3. Determine the sign, exponent (power of 2), and the digits to the right of the binary point of your normalized result. For this example, the sign is 0 because 3.5 is positive; the exponent is 1, and the digits to the right of the binary point are 11. 4. Determine the biased exponent by adding 12710 to the exponent for a 32-bit Real value, and by adding 102310 to a 64-bit LReal value. For the example of 3.5, the biased exponent is 12810 for a Real and 102410 for an LReal. Determine the binary representation of this biased exponent. The binary representation of 12810 is 100000002. (Precede with 0's as necessary to form an 8-bit biased exponent for a Real, or an 11-bit biased exponent for an LReal.) 5. Represent the mantissa in 23 bits for a Real or 52 bits for an LReal by adding 0's to the end of the digits to the right of the binary point in Step 3 for the required number of bits. Update to the S7-1200 System Manual, edition 01/2015 4 A5E03666852-AB, 03/2015 6. For example, the representation for 3.5 in both 32-bit and 64-bit IEEE 754 representation is as follows: Sign Exponent Mantissa 0 10000000 11000000000000000000000 32-bit Real representation in IEEE 754 format Sign Exponent Mantissa 0 10000000000 1100000000000000000000000000000000000000000000000000 64-bit LReal representation in IEEE 754 format 7. Convert the binary representation to Hexadecimal. Use a Hexadecimal digit 0 - F to correspond to each group of four binary digits. Binary to Hexadeximal conversion 0000 = 0 0100 = 4 1000 = 8 1100 = C 0001 = 1 0101 = 5 1001 = 9 1101 = D 0010 = 2 0110 = 6 1010 = A 1110 = E 0011 = 3 0111 = 7 1011 = B 1111 = F Converting to Hexadecimal, the 32-bit IEEE 754 representation of 3.5 is as follows: 0100 0000 0110 0000 0000 0000 0000 00002 = 4060 000016 Correspondingly, the 64-bit is as follows: 0100 0000 0000 1100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 2 = 400C 0000 0000 000016 Note You can find conversion tools to help with the numeric conversions, especially for numbers that do not convert easily from decimal to IEEE 754 format. Entering binary and Hexadecimal numbers in the Web server In Variable Status fields you precede binary numbers with 2# and Hexadecimal numbers with 16#. For the floating point value of 3.5, you could enter any of the following representations: Real: 2#01000000011000000000000000000000 Real: 16#40600000 LReal: 2#0100000000001100000000000000000000000000000000000000000000000000 LReal: 16#400C000000000000 Effect on remote wind turbine monitor example The remote wind turbine monitor example in the S7-1200 System Manual makes frequent use of writable floating point fields in a user-defined Web page. The S7-1200 V4.1 CPU no longer supports this example in its current form. Start information for the hardware interrupt OB The information in the following table supplements the information in the S7-1200 System Manual section 5.1.3.5, "Hardware interrupt OB": Input LADDR USI IChannel EventType Data type HW_IO WORD USINT BYTE Description Hardware identifier of the module that triggers the hardware interrupt Identifier for future extensions (not user-relevant) Number of the channel that triggered the hardware interrupt Identifier for the event type associated with the event triggering the interrupt (for example, positive edge) This identifier can be found in the description of the respective module. Update to the S7-1200 System Manual, edition 01/2015 A5E03666852-AB, 03/2015 5 CM 1241 V2.1 firmware required for Point-to-Point, Modbus RTU, and USS library instructions The S7-1200 CM 1241 firmware update V2.1 is necessary for the CM 1241 communication modules to support the new Point-to-Point, Modbus RTU, and USS library instructions that the S7-1200 V4.1 Programmable Controller System Manual describes. Without the V2.1 firmware update, the CM 1241 communication modules support only the legacy versions of these communication instructions. Use of the DPRD_DAT and DPWR_DAT instructions to access consistent data The DPRD_DAT and DPWR_DAT instruction descriptions are corrected and shown below: Table 2 DPRD_DAT and DPWR_DAT instructions LAD / FBD SCL ret_val := DPRD_DAT( laddr:=_word_in_, record=>_variant_out_); ret_val := DPWR_DAT( laddr:=_word_in_, record:=_variant_in_); Description Use the DPRD_DAT instruction to read one or more bytes of data from one of the following locations: · Module or submodule in the local base · DP standard slave · PROFINET I/O device The CPU transfers the data read consistently. If no errors occur during the data transfer, the CPU enters the read data into the target area set up by the RECORD parameter. The target area must have the same length as you configured with STEP 7 for the selected module. When you execute the DPRD_DAT instruction, you can only access the data of one module or submodule. The transfer starts at the configured start address. Use the DPWR_DAT instruction to transfer the data in RECORD consistently to the following locations: · Addressed module or submodule in the local base · DP standard slave · PROFINET I/O device The source area must have the same length as you configured with STEP 7 for the selected module or submodule. PROFIBUS supports up to 4 bytes of consistent data. Use the DPRD_DAT and DPWR_DAT instructions to access more than 4 bytes of data consistently. Update to the S7-1200 System Manual, edition 01/2015 6 A5E03666852-AB, 03/2015 CE approval - EC Directive 94/9/EC (ATEX) update The CE approval, EC Directive 94/9/EC (ATEX) has been updated to include EN 60079-0:2012 as shown below. The S7-1200 Automation System satisfies requirements and safety related objectives according to the EC directives listed below, and conforms to the harmonized European standards (EN) for the programmable controllers listed in the Official Journals of the European Community. EC Directive 2006/95/EC (Low Voltage Directive) "Electrical Equipment Designed for Use within Certain Voltage Limits" EN 61131-2:2007 Programmable controllers - Equipment requirements and tests EC Directive 2004/108/EC (EMC Directive) "Electromagnetic Compatibility" Emission standard EN 61000-6-4:2007+A1:2011: Industrial Environment Immunity standard EN 61000-6-2:2005: Industrial Environment EC Directive 94/9/EC (ATEX) "Equipment and Protective Systems Intended for Use in Potentially Explosive Atmosphere" EN 60079-0:2012 + A11:2013 EN 60079-15:2010: Type of Protection 'n' The CE Declaration of Conformity is held on file available to competent authorities at: Siemens AG Sector Industry DF FA AS DH AMB Postfach 1963 D-92209 Amberg Germany Wiring rules The wiring guidelines section includes the following updates: Table 3 Wiring rules for S7-1200 CPUs, SMs, and SBs Wiring rules for... CPU and SM connector SB connector Connectible conductor crosssections for standard wires Number of wires per connection Wire strip length Tightening torque* (maximum) Tool 2 mm2 to 0.3 mm2 (14 AWG to 22 AWG) 1 or combination of 2 wires up to 2 mm2 (total) 6.4 mm 0.56 N-m (5 inch-pounds) 2.5 to 3.0 mm flathead screwdriver 1.3 mm2 to 0.3 mm2 (16 AWG to 22 AWG) 1 or combination of 2 wires up to 1.3 mm2 (total) 6.3 to 7 mm 0.33 N-m (3 inch-pounds) 2.0 to 2.5 mm flathead screwdriver * To avoid damaging the connector, be careful that you do not over-tighten the screws. Note Ferrules or end sleeves on stranded conductors reduce the risk of stray strands causing short circuits. Ferrules longer than the recommended strip length should include an insulating collar to prevent shorts due to side movement of conductors. Cross-sectional area limits for bare conductors also apply to ferrules. Update to the S7-1200 System Manual, edition 01/2015 A5E03666852-AB, 03/2015 7 Correction of terminal block spare kits ordering information The S7-1200 CPU V4.0 and later - Terminal block spare kits (Table C-16) and S7-1200 SMs V4.0 and later - Terminal block spare kits (Table C-17) are corrected and shown below: Table 4 S7-1200 CPU V4.0 and later - Terminal block spare kits - corrections If you have S7-1200 CPU V4.0 and later (article number) CPU 1211C DC/DC/Relay (6ES7 211-1HE40-0XB0) CPU 1212C DC/DC/Relay (6ES7 212-1HE40-0XB0) CPU 1215C DC/DC/DC (6ES7 215-1AG40-0XB0) Use this terminal block spare kit (4/pk) Terminal block article number Terminal block description 6ES7 292-1BC30-0XA0 3 pin, gold-plated 6ES7 292-1AH40-0XA0 8 pin, tin-plated, keyed 6ES7 292-1AP30-0XA0 14 pin, tin-plated 6ES7 292-1BC30-0XA0 3 pin, gold-plated 6ES7292-1AH40-0XA0 8 pin, tin-plated, keyed 6ES7 292-1AP30-0XA0 14 pin, tin-plated 6ES7 292-1BF30-0XB0 6 pin, gold-plated 6ES7 292-1AM30-0XB0 12 pin, tin-plated 6ES7 292-1AV30-0XB0 20 pin, tin-plated Table 5 S7-1200 SMs V4.0 and later - Terminal block spare kits If you have S7-1200 SM V4.0 and later (article number) SM1231 AI8 x RTD (6ES7 231-5PF32-0XB0) Use this terminal block spare kit (4/pk) Terminal block article number Terminal block description 6ES7 292-1BL30-0XA0 11 pin, gold-plated Update to the S7-1200 System Manual, edition 01/2015 8 A5E03666852-AB, 03/2015 SM 1231, SM 1234, and SB 1231 wiring current transducers Wiring current transducers are available as 2-wire transducers and 4-wire transducers. The SM and SB models affected are: SM 1231 AI 4 x 13 bit (6ES7 231-4HD32-0XB0) SM 1231 AI 8 x 13 bit (6ES7 231-4HF32-0XB0) SM 1231 AI 4 x 16 bit (6ES7 231-5ND30-0XB0) SM 1234 4 x Analog Input / 2 x Analog Output (6ES7 234-4HE32-0XB0) SB 1231 AI 1 x 12 bit (6ES7 231-4HA30-0XB0) Figure 3 SM 1231 and SM 1234 wiring current transducer Figure 4 SB 1231 wiring current transducer Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG Update to the S7-1200 System Manual, edition 01/2015 AA55EE0033666666885522--AABB,, 0033//22001155 9DF FA S ID Adobe PDF Library 10.0