Data sheet

6ES7214-1AG40-0XB0
SIMATIC S7-1200, CPU 1214C, compact CPU, DC/DC/DC, onboard I/O: 14 DI 24 V DC; 10 DO 24 V DC; 2 AI 0-10 V DC, Power supply: DC 20.4-28.8V DC, Program/data memory 100 KB

General information Product type designation Firmware version Engineering with  Programming package
Supply voltage Rated value (DC)  24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) Reverse polarity protection Load voltage L+  Rated value (DC)  permissible range, lower limit (DC)  permissible range, upper limit (DC)
Input current Current consumption (rated value) Current consumption, max. Inrush current, max. I²t
Output current for backplane bus (5 V DC), max.
Encoder supply 24 V encoder supply  24 V
Power loss Power loss, typ.
Memory Work memory  integrated Load memory  integrated  Plug-in (SIMATIC Memory Card), max. Backup  present  maintenance-free  without battery
CPU processing times for bit operations, typ.
6ES72141AG400XB0 Page 1/7

CPU 1214C DC/DC/DC V4.5
STEP 7 V17 or higher

Yes 20.4 V 28.8 V Yes
24 V 20.4 V 28.8 V
500 mA; CPU only 1 500 mA; CPU with all expansion modules 12 A; at 28.8 V 0.5 A²·s
1 600 mA; Max. 5 V DC for SM and CM

L+ minus 4 V DC min. 12 W

100 kbyte
4 Mbyte with SIMATIC memory card
Yes Yes Yes
0.08 µs; / instruction
6/29/2023

Subject to change without notice © Copyright Siemens

for word operations, typ. for floating point arithmetic, typ. CPU-blocks Number of blocks (total)
OB  Number, max.
Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. Flag  Size, max. Local data  per priority class, max.
Address area Process image  Inputs, adjustable  Outputs, adjustable
Hardware configuration Number of modules per system, max.
Time of day Clock  Hardware clock (real-time)  Backup time  Deviation per day, max.
Digital inputs Number of digital inputs  of which inputs usable for technological functions Source/sink input Number of simultaneously controllable inputs all mounting positions -- up to 40 °C, max. Input voltage  Rated value (DC)  for signal "0"  for signal "1" Input delay (for rated value of input voltage) for standard inputs -- parameterizable
-- at "0" to "1", min. -- at "0" to "1", max. for interrupt inputs -- parameterizable for technological functions -- parameterizable
Cable length  shielded, max.  unshielded, max.
Digital outputs Number of digital outputs  of which high-speed outputs Limitation of inductive shutdown voltage to Switching capacity of the outputs  with resistive load, max.  on lamp load, max. Output voltage  for signal "0", max.  for signal "1", min. Output current
6ES72141AG400XB0 Page 2/7

1.7 µs; / instruction 2.3 µs; / instruction
DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
Limited only by RAM for code
14 kbyte
8 kbyte; Size of bit memory address area
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
1 kbyte 1 kbyte
3 comm. modules, 1 signal board, 8 signal modules
Yes 480 h; Typical ±60 s/month at 25 °C
14; Integrated 6; HSC (High Speed Counting) Yes
14
24 V 5 V DC at 1 mA 15 V DC at 2.5 mA
0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms
Yes
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
500 m; 50 m for technological functions 300 m; for technological functions: No
10 4; 100 kHz Pulse Train Output L+ (-48 V)
0.5 A 5 W
0.1 V; with 10 kOhm load 20 V

6/29/2023

Subject to change without notice © Copyright Siemens

 for signal "1" rated value  for signal "0" residual current, max. Output delay with resistive load  "0" to "1", max.  "1" to "0", max. Switching frequency  of the pulse outputs, with resistive load, max. Relay outputs  Number of relay outputs Cable length  shielded, max.  unshielded, max. Analog inputs Number of analog inputs Input ranges  Voltage Input ranges (rated values), voltages  0 to +10 V
-- Input resistance (0 to 10 V) Cable length
 shielded, max. Analog outputs
Number of analog outputs Analog value generation for the inputs
Integration and conversion time/resolution per channel  Resolution with overrange (bit including sign), max.  Integration time, parameterizable  Conversion time (per channel)
Encoder Connectable encoders  2-wire sensor
1. Interface Interface type Isolated automatic detection of transmission rate Autonegotiation Autocrossing Interface types  RJ 45 (Ethernet)  Number of ports  integrated switch Protocols  PROFINET IO Controller  PROFINET IO Device  SIMATIC communication  Open IE communication  Web server  Media redundancy PROFINET IO Controller  Transmission rate, max. Services -- PG/OP communication -- Isochronous mode -- IRT -- PROFIenergy -- Prioritized startup -- Number of IO devices with prioritized startup, max. -- Number of connectable IO Devices, max. -- Number of connectable IO Devices for RT, max. -- of which in line, max.

0.5 A 0.1 mA
1 µs 5 µs
100 kHz
0
500 m 150 m
2
Yes
Yes 100k ohms
100 m; twisted and shielded
0
10 bit Yes 625 µs
Yes
PROFINET Yes Yes Yes Yes
Yes 1 No
Yes Yes Yes Yes; Optionally also encrypted Yes No
100 Mbit/s
Yes; encryption with TLS V1.3 pre-selected No No No Yes 16 16 16 16

6ES72141AG400XB0 Page 3/7

6/29/2023

Subject to change without notice © Copyright Siemens

-- Activation/deactivation of IO Devices -- Number of IO Devices that can be simultaneously activated/deactivated, max. -- Updating time
PROFINET IO Device Services -- PG/OP communication -- Isochronous mode -- IRT -- PROFIenergy -- Shared device -- Number of IO Controllers with shared device, max.
Protocols Supports protocol for PROFINET IO PROFIsafe PROFIBUS OPC UA AS-Interface Protocols (Ethernet)  TCP/IP  DHCP  SNMP  DCP  LLDP Redundancy mode Media redundancy -- MRP -- MRPD SIMATIC communication  S7 routing Open IE communication  TCP/IP -- Data length, max.  ISO-on-TCP (RFC1006) -- Data length, max.  UDP -- Data length, max. Web server  supported  User-defined websites OPC UA  Runtime license required  OPC UA Server -- Application authentication
-- User authentication -- Number of sessions, max. -- Number of subscriptions per session, max. -- Sampling interval, min. -- Publishing interval, min. -- Number of server methods, max. -- Number of monitored items, recommended max. -- Number of server interfaces, max. -- Number of nodes for user-defined server interfaces, max. Further protocols  MODBUS communication functions / header S7 communication  supported

Yes 8
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
Yes; encryption with TLS V1.3 pre-selected No No Yes Yes 2
Yes No Yes; CM 1243-5 (master) or CM 1242-5 (slave) required Yes; OPC UA Server Yes; CM 1243-2 required
Yes No Yes Yes Yes
No No
Yes
Yes 8 kbyte Yes 8 kbyte Yes 1 472 byte
Yes Yes
Yes; "Basic" license required Yes; data access (read, write, subscribe), method call, runtime license required Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 "anonymous" or by user name & password 10 5 100 ms 200 ms 20 1 000 2 2 000
Yes
Yes

6ES72141AG400XB0 Page 4/7

6/29/2023

Subject to change without notice © Copyright Siemens

 as server

Yes

 as client

Yes

 User data per job, max.

See online help (S7 communication, user data size)

Number of connections

 overall

PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max

Test commissioning functions

Status/control

 Status/control variable

Yes

 Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

Forcing

 Forcing

Yes

Diagnostic buffer

 present

Yes

Traces

 Number of configurable Traces

2

 Memory size per trace, max.

512 kbyte

Interrupts/diagnostics/status information

Diagnostics indication LED

 RUN/STOP LED

Yes

 ERROR LED

Yes

 MAINT LED

Yes

Integrated Functions

Counter

 Number of counters

6

 Counting frequency, max.

100 kHz

Frequency measurement

Yes

controlled positioning

Yes

Number of position-controlled positioning axes, max.

8

Number of positioning axes via pulse-direction interface

4; With integrated outputs

PID controller

Yes

Number of alarm inputs

4

Number of pulse outputs

4

Limit frequency (pulse)

100 kHz

Potential separation

Potential separation digital inputs

 Potential separation digital inputs

No

 between the channels, in groups of

1

Potential separation digital outputs

 Potential separation digital outputs

Yes

 between the channels

No

 between the channels, in groups of

1

EMC

Interference immunity against discharge of static electricity

 Interference immunity against discharge of static

Yes

electricity acc. to IEC 61000-4-2

-- Test voltage at air discharge

8 kV

-- Test voltage at contact discharge

6 kV

Interference immunity to cable-borne interference

 Interference immunity on supply lines acc. to IEC 61000-

Yes

4-4

 Interference immunity on signal cables acc. to IEC 61000- Yes 4-4

Interference immunity against voltage surge

 Interference immunity on supply lines acc. to IEC 61000-

Yes

4-5

Interference immunity against conducted variable disturbance induced by high-frequency fields

 Interference immunity against high-frequency radiation

Yes

acc. to IEC 61000-4-6

Emission of radio interference acc. to EN 55 011

 Limit class A, for use in industrial areas

Yes; Group 1

6ES72141AG400XB0 Page 5/7

6/29/2023

Subject to change without notice © Copyright Siemens

 Limit class B, for use in residential areas
Degree and class of protection IP degree of protection
Standards, approvals, certificates CE mark UL approval cULus FM approval RCM (formerly C-TICK) KC approval Marine approval
Ambient conditions Free fall  Fall height, max. Ambient temperature during operation  min.  max.
 horizontal installation, min.  horizontal installation, max.  vertical installation, min.  vertical installation, max. Ambient temperature during storage/transportation  min.  max. Air pressure acc. to IEC 60068-2-13  Operation, min.  Operation, max.  Storage/transport, min.  Storage/transport, max. Altitude during operation relating to sea level  Installation altitude, min.  Installation altitude, max. Relative humidity  Operation, max. Vibrations  Vibration resistance during operation acc. to IEC 600682-6  Operation, tested according to IEC 60068-2-6 Shock testing  tested according to IEC 60068-2-27
Pollutant concentrations  SO2 at RH < 60% without condensation
configuration / header configuration / programming / header Programming language -- LAD -- FBD -- SCL Know-how protection  User program protection/password protection  Copy protection  Block protection Access protection  protection of confidential configuration data  Protection level: Write protection  Protection level: Read/write protection  Protection level: Complete protection programming / cycle time monitoring / header

Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
IP20
Yes Yes Yes Yes Yes Yes Yes
0.3 m; five times, in product package
-20 °C 60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical -20 °C 60 °C -20 °C 50 °C
-40 °C 70 °C
795 hPa 1 080 hPa 660 hPa 1 080 hPa
-1 000 m 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
95 %; no condensation
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
Yes
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Yes Yes Yes
Yes Yes Yes
Yes Yes Yes Yes

6ES72141AG400XB0 Page 6/7

6/29/2023

Subject to change without notice © Copyright Siemens

 adjustable Dimensions
Width Height Depth Weights Weight, approx.
last modified:

Yes
110 mm 100 mm 75 mm
415 g 7/19/2022

6ES72141AG400XB0 Page 7/7

6/29/2023

Subject to change without notice © Copyright Siemens

