SIMATIC S7-1200F, CPU 1215 FC, compact CPU, DC/DC/DC, 2 PROFINET ports, onboard I/O: 14 DI 24 V DC; 10 DO 24 V DC; 0.5A; 2 AI 0-10 V DC, 2 AO 0-20 mA DC, Power supply: DC 20.4-28.8V DC, Program/data memory 150 KB
Description of the visual: A photograph of a Siemens SIMATIC S7-1200F CPU module. The module is a compact industrial automation controller with a grey casing, featuring multiple slots for expansion modules, front-facing connectors, status LEDs, and branding.
General information
Product type designation | CPU 1215FC DC/DC/DC |
---|---|
Firmware version | V4.2 |
Engineering with | STEP 7 V14 or higher |
Supply voltage
Rated value (DC) | 24 V DC |
---|---|
Permissible range, lower limit (DC) | 20.4 V |
Permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Load voltage L+
Rated value (DC) | 24 V |
---|---|
Permissible range, lower limit (DC) | 20.4 V |
Permissible range, upper limit (DC) | 28.8 V |
Input current
Current consumption (rated value) | 500 mA; CPU only |
---|---|
Current consumption, max. | 1 500 mA; CPU with all expansion modules |
Inrush current
Inrush current, max. | 12 A; at 28.8 V DC |
---|---|
I²t | 0.5 A²s |
Output current
For backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
---|
Encoder supply
24 V encoder supply | L+ minus 4 V DC min. |
---|
Power loss
Power loss, typ. | 12 W |
---|
Memory
Work memory |
|
---|---|
Load memory |
|
Backup |
|
CPU processing times
For bit operations, typ. | 0.08 μs; / instruction |
---|---|
For word operations, typ. | 1.7 μs; / instruction |
For floating point arithmetic, typ. | 2.3 μs; / instruction |
CPU-blocks
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used. |
---|
OB
Number, max. | Limited only by RAM for code |
---|
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. | 10 kbyte |
---|---|
Flag |
|
Local data |
|
Address area
Process image |
---|
Hardware configuration
Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
---|
Time of day
Clock | |
---|---|
• Hardware clock (real-time) | Yes |
• Backup time | 480 h; Typical |
• Deviation per day, max. | 60 s/month at 25 °C |
Digital inputs
Number of digital inputs | 14; Integrated |
---|---|
Of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | 14 |
All mounting positions | |
Up to 40 °C, max. |
Input voltage
Rated value (DC) | 24 V |
---|---|
For signal "0" | 5 V DC at 1 mA |
For signal "1" | 15 V DC at 2.5 mA |
Input delay (for rated value of input voltage)
For standard inputs | |
---|---|
• Parameterizable | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
• At "0" to "1", min. | 0.2 ms |
• At "0" to "1", max. | 12.8 ms |
For interrupt inputs | |
• Parameterizable | Yes |
For technological functions | |
• Parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
Cable length
Shielded, max. | 500 m; 50 m for technological functions |
---|---|
Unshielded, max. | 300 m; for technological functions: No |
Digital outputs
Number of digital outputs | 10 |
---|---|
Of which high-speed outputs | 4; 100 kHz Pulse Train Output |
Limitation of inductive shutdown voltage to | L+ (-48 V) |
Switching capacity of the outputs | |
• With resistive load, max. | 0.5 A |
• On lamp load, max. | 5 W |
Output voltage
For signal "0", max. | 0.1 V; with 10 kOhm load |
---|---|
For signal "1", min. | 20 V |
Output current
For signal "1" rated value | 0.5 A |
---|---|
For signal "0" residual current, max. | 0.1 mA |
Output delay with resistive load
"0" to "1", max. | 1 μs |
---|---|
"1" to "0", max. | 5 μs |
Switching frequency
Of the pulse outputs, with resistive load, max. | 100 kHz |
---|
Relay outputs
Number of relay outputs | 0 |
---|
Cable length
Shielded, max. | 500 m |
---|---|
Unshielded, max. | 150 m |
Analog inputs
Number of analog inputs | 2 |
---|---|
Input ranges | |
• Voltage | Yes |
Input ranges (rated values), voltages | 0 to +10 V |
• Input resistance (0 to 10 V) | ≥100k ohms |
Cable length
Shielded, max. | 100 m; twisted and shielded |
---|
Analog outputs
Number of analog outputs | 2 |
---|---|
Output ranges, current | |
• 0 to 20 mA | Yes |
Analog value generation for the inputs
Integration and conversion time/resolution per channel | |
---|---|
• Resolution with overrange (bit including sign), max. | 10 bit |
• Integration time, parameterizable | Yes |
• Conversion time (per channel) | 625 μs |
Analog value generation for the outputs
Integration and conversion time/resolution per channel | |
---|---|
• Resolution with overrange (bit including sign), max. | 10 bit |
Encoder
Connectable encoders | |
---|---|
• 2-wire sensor | Yes |
1. Interface
Interface type | PROFINET |
---|---|
Isolated | Yes |
Automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types
• RJ 45 (Ethernet) | |
---|---|
• Number of ports | 2 |
• Integrated switch | Yes |
Protocols
• PROFINET IO Controller | Yes |
---|---|
• PROFINET IO Device | Yes |
• SIMATIC communication | Yes |
• Open IE communication | Yes |
• Web server | Yes |
• Media redundancy | Yes; as MRP client |
PROFINET IO Controller
Transmission rate, max. | 100 Mbit/s |
---|
Services
• PG/OP communication | Yes |
---|---|
• Isochronous mode | No |
• IRT | No |
• MRP | Yes; as MRP client |
• MRPD | No |
• PROFIenergy | No |
• Prioritized startup | Yes |
Number of IO devices with prioritized startup, max. | 16 |
Number of connectable IO Devices, max. | 16 |
Number of connectable IO Devices for RT, max. | 16 |
Of which in line, max. | 16 |
Activation/deactivation of IO Devices | Yes |
Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
PROFINET IO Device
Services
• PG/OP communication | Yes |
---|---|
• Isochronous mode | No |
• IRT | No |
• MRP | Yes; as MRP client |
• MRPD | No |
• PROFIenergy | Yes |
• Shared device | Yes |
Number of IO Controllers with shared device, max. | 2 |
Protocols
Supports protocol for PROFINET IO | Yes |
---|---|
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet)
• TCP/IP | Yes |
---|---|
• DHCP | No |
• SNMP | Yes |
• DCP | Yes |
• LLDP | Yes |
SIMATIC communication
S7 routing | Yes |
---|
Open IE communication
• TCP/IP | Yes |
---|---|
Data length, max. | 8 kbyte |
• ISO-on-TCP (RFC1006) | Yes |
Data length, max. | 8 kbyte |
• UDP | Yes |
Data length, max. | 1 472 byte |
Web server
• Supported | Yes |
---|---|
• User-defined websites | Yes |
Further protocols
• MODBUS | Yes |
---|
Communication functions
S7 communication | |
---|---|
• Supported | Yes |
• As server | Yes |
• As client | Yes |
• User data per job, max. | See online help (S7 communication, user data size) |
Test commissioning functions
Status/control | |
---|---|
• Status/control variable | Yes |
• Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | |
• Forcing | Yes |
Diagnostic buffer | |
• Present | Yes |
Traces
Number of configurable Traces | 2 |
---|---|
Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information
Diagnostics indication LED | |
---|---|
• RUN/STOP LED | Yes |
• ERROR LED | Yes |
• MAINT LED | Yes |
Integrated Functions
Number of counters | 6 |
---|---|
Counting frequency (counter) max. | 100 kHz |
Frequency measurement | Yes |
Controlled positioning | Yes |
Number of position-controlled positioning axes, max. | 8 |
Number of positioning axes via pulse-direction interface | 4; With integrated outputs |
PID controller | Yes |
Number of alarm inputs | 4 |
Number of pulse outputs | 4 |
Limit frequency (pulse) | 100 kHz |
Potential separation
Potential separation digital inputs | |
---|---|
• Potential separation digital inputs | No |
• Between the channels, in groups of | 1 |
Potential separation digital outputs | |
• Potential separation digital outputs | Yes |
• Between the channels | No |
• Between the channels, in groups of | 1 |
EMC
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
---|---|
Test voltage at air discharge | 8 kV |
Test voltage at contact discharge | 6 kV |
Interference immunity to cable-borne interference
Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes |
---|---|
Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
Interference immunity against voltage surge
Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
---|
Interference immunity against conducted variable disturbance induced by high-frequency fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
---|
Emission of radio interference acc. to EN 55011
Limit class A, for use in industrial areas | Yes; Group 1 |
---|---|
Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection
IP degree of protection | IP20 |
---|
Standards, approvals, certificates
CE mark | Yes |
---|---|
UL approval | Yes |
cULus | Yes |
FM approval | Yes |
KC approval | Yes |
Marine approval | Yes |
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1 | PLe |
---|---|
SIL acc. to IEC 61508 | SIL 3 |
Ambient conditions
Free fall
Fall height, max. | 0.3 m; five times, in product package |
---|
Ambient temperature during operation
Min. | 0 °C |
---|---|
Max. | 55 °C |
Horizontal installation, min. | 0 °C |
Horizontal installation, max. | 55 °C |
Vertical installation, min. | 0 °C |
Vertical installation, max. | 45 °C |
Ambient temperature during storage/transportation
Min. | -40 °C |
---|---|
Max. | 70 °C |
Air pressure acc. to IEC 60068-2-13
Operation, min. | 795 hPa |
---|---|
Operation, max. | 1 080 hPa |
Storage/transport, min. | 660 hPa |
Storage/transport, max. | 1 080 hPa |
Relative humidity
Operation, max. | 95 %; no condensation |
---|
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
---|---|
Operation, tested according to IEC 60068-2-6 | Yes |
Shock testing
Tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
---|
Pollutant concentrations
SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
---|
Configuration
Programming
Programming language | |
---|---|
• LAD | Yes; incl. failsafe |
• FBD | Yes; incl. failsafe |
• SCL | Yes |
Know-how protection
• User program protection/password protection | Yes |
---|---|
• Copy protection | Yes |
• Block protection | Yes |
Access protection
• Protection level: Write protection | Yes |
---|---|
• Protection level: Read/write protection | Yes |
• Protection level: Complete protection | Yes |
Cycle time monitoring
• Adjustable | Yes |
---|
Dimensions
Width | 130 mm |
---|---|
Height | 100 mm |
Depth | 75 mm |
Weights
Weight, approx. | 585 g |
---|