Features
The EverStart maxx PPS1CWE is a versatile 1000A jump starter with integrated wireless charging and air compressor capabilities. Key features include:
- 1. Carry Handle: For easy portability.
- 2. Wireless Charging Pad: For charging compatible devices.
- 3. LED Area Light: Provides illumination.
- 4. LCD Screen: Displays battery status, voltage, and other information.
- 5. LED Light Power Button: Controls the LED area light.
- 6. Decrease Compressor Pressure Control Button (-): Adjusts compressor pressure downwards.
- 7. Boost Cables: Heavy-duty cables for jump-starting vehicles.
- 8. Alternator Check Button: Initiates an alternator diagnostic test.
- 9. Compressor Power Button: Turns the air compressor on/off.
- 10. Wireless Charging Button: Activates the wireless charging function.
- 11. USB Power Button: Activates the USB power ports.
- 12. Increase Compressor Pressure Control Button (+): Adjusts compressor pressure upwards.
- 13. USB Ports: Two USB ports for charging devices (5V DC, 3.1A max total). Includes USB Power/Fault Indicators.
- 14. AC Charging Port: For recharging the unit via AC adapter.
- 15. Air Hose and Sure Fit® Nozzle: For inflating tires and other items.
- 16. Boost Cables Connector: Connects the boost cables to the unit.
- 17. Clamp Connection Slot: Storage for the boost cables connector.
- 18. Air Hose and Sure Fit® Nozzle in Hose Storage Groove: Integrated storage for the air hose and nozzle.
- 19. Nozzle Adapter: For inflating items without standard valve stems.
- 20. AC Charging Adapter: Powers and recharges the unit.
Safety Guidelines and Definitions
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property damage.
RISK OF UNSAFE OPERATION: Always follow basic safety precautions. Improper operation, maintenance, or modification can lead to serious injury and property damage. Use this product only for its intended purpose.
READ ALL INSTRUCTIONS: Failure to follow instructions may result in electric shock, fire, or serious injury.
General Safety Warnings and Instructions
- Designed for household use only.
- Avoid damp or wet locations; do not use in the rain.
- Keep children and unauthorized persons away from the work area.
- Dress properly: avoid loose clothing or jewelry. Wear rubber gloves and non-skid footwear when working outdoors. Contain long hair.
- Store idle appliances indoors in a dry, locked-up place, out of reach of children.
- Do not abuse the power cord. Keep it away from heat, oil, and sharp edges.
- Disconnect the appliance from the power supply when not in use, before servicing, or when changing accessories.
- Use Ground Fault Circuit Interrupter (GFCI) protection on circuits or outlets.
- Use only recommended accessories.
- Stay alert and use common sense; do not operate when tired or impaired.
- Check for damaged parts. Contact the manufacturer if any part is damaged or if the switch does not operate correctly.
- Do not operate near flammable liquids or in gaseous/explosive atmospheres. Motors spark and may ignite fumes.
- Never submerge the unit in water; do not expose it to rain or snow.
- Disconnect from power source before maintenance or cleaning.
- This equipment produces arcs or sparks; place it at least 18 inches above the floor in garages or enclosed areas.
Specific Safety Instructions for Charging This Unit
- IMPORTANT: Charge the unit for a full 20 hours before first use.
- Use only the supplied AC charger.
- Ensure all power switches are OFF when charging or when the unit is not in use.
Extension Cords
WARNING: Use of improper extension cords can lead to fire and electric shock. Ensure the cord's pins match the charger's, and use a cord heavy enough for the product's current draw. Refer to the table for correct gauge based on length and amperage.
Volts | Total Length of Cord in Feet | Ampere Rating | Extension Cord Length | American Wire Gauge (AWG) | |||
---|---|---|---|---|---|---|---|
0-25 (0-7.6m) | 26-50 (7.6-15.2m) | 51-100 (15.2-30.4m) | 101-150 (30.4-45.7m) | ||||
120V | More Than 0-6 | 0'-25' | 18 | ||||
6-10 | 26'-50' | 16 | |||||
10-12 | 51'-100' | 16 | |||||
12-16 | 101'-150' | 14 | |||||
240V | 0-50 (0-15.2m) | 51-100 (15.2-30.4m) | 101-200 (30.4-60.9m) | 201-300 (60.9-91.4m) | More Than 0-6 | 0'-25' | 18 |
6-10 | 26'-50' | 16 | |||||
10-12 | 51'-100' | 14 | |||||
12-16 | 101'-150' | 12 | |||||
More Than 16 | Not Recommended |
Ensure extension cords are properly wired, in good condition, and the wire size is adequate.
Specific Safety Instructions for Wireless Charging
CAUTION: Do not use the Jump-Starter or Compressor while using the Wireless Charging function. Place the appliance in the center of the Wireless Charging Pad.
Specific Safety Instructions for Jump Starters
WARNING - Burst hazard: Do not use for dry-cell batteries. Use only for lead-acid batteries. Never use to supply power to low-voltage systems other than starter motors.
WARNING - Risk of explosive gases: Batteries generate explosive gases. Work in a well-ventilated area. Never smoke or allow sparks/flames near batteries. Follow all instructions and cautionary markings.
CAUTION: NEVER attempt to jump-start or charge a frozen battery.
- Check vehicle owner's manual for compatibility with jump-starting.
- Have assistance available in case of accident.
- Stay clear of moving vehicle parts (fan blades, belts, pulleys).
- Remove metal jewelry (rings, bracelets, watches) to prevent short circuits and burns.
- Do not wear vinyl clothing, as friction can cause static sparks.
- Be careful not to drop metal tools onto the battery; this can cause sparks or explosion.
- Perform jump-start procedures in a safe, dry, well-ventilated area.
- Store battery clamps when not in use. Never touch clamps together.
- Keep clamps, cords, clothing, and body parts away from moving vehicle parts.
- Never allow red and black clamps to touch each other or common metal conductors.
- If clamps are connected incorrectly, the LCD will display polarity error icons and an alarm will sound. Disconnect and reconnect with correct polarity.
- Always disconnect the negative (black) cable first, then the positive (red) cable (except for positive grounded systems).
- Do not expose the battery to fire or intense heat. Protect terminals with tape before disposal.
- Place the unit as far from the battery as cables permit.
- Never allow battery acid to contact the unit.
- Do not operate in a closed area or restrict ventilation.
- This system is designed for 12-volt DC battery systems only. Do not connect to 6V or 24V systems.
- This system is not a replacement for a vehicle battery. Do not operate a vehicle without a battery.
- Excessive engine cranking can damage the starter motor. Discontinue if the engine fails to start after recommended attempts.
- Do not use on watercraft; not qualified for marine applications.
- Keep the unit upright during storage, use, and recharging to avoid damage. Protect from direct sunlight, heat, and moisture.
Specific Safety Instructions for Compressors
WARNING - BURST HAZARD: Follow instructions on items to be inflated. Never exceed recommended pressure. Monitor pressure gauge at all times.
CAUTION: Never leave the compressor unattended. Do not operate continuously for longer than approximately 10 minutes, as it may overheat and cause damage. Allow to cool before resuming.
First Aid
Battery Acid Contact:
- Skin: Rinse immediately with water, then wash thoroughly with soap and water. Seek medical attention if redness, pain, or irritation occurs.
- Eyes: Flush eyes immediately with clean water for at least 15 minutes. Seek immediate medical attention.
LCD Liquid Crystal Contact:
- Skin: Wash area completely with water. Remove contaminated clothing.
- Eye: Flush affected eye with clean water. Seek medical attention.
- Swallowed: Flush mouth with water. Drink large quantities of water and induce vomiting. Seek medical attention.
Always have protective eyewear and immediate assistance available when working with lead-acid batteries.
Overview: Common Actions and Unit Responses
Pressing the following buttons activates the unit and the LCD screen:
- LED Area Light Power Button: Unit beeps, Area Light turns ON, LCD backlight on for 10s. Unit stays on until button is pressed again.
- Alternator Check Button: Unit beeps, LCD backlight on for 10s, Battery Status Icon and Alternator Icon flash. Unit stays on until button is pressed again.
- Wireless Charging Button: Unit beeps, LCD backlight on for 10s, Wireless Charging Indicator flashes. Unit stays on until button is pressed again or no device is detected for 3 minutes.
- USB Power Button: Unit beeps, LCD backlight on for 10s, Battery Status Icon, Voltage Icon, and USB Icon display. USB Power/Fault Indicators light solid blue. Unit stays on until button is pressed again.
- Compressor Power Button: Unit beeps, LCD displays Battery Status Icon, PSI, and Compressor Icon. Unit turns off after 1 minute of inactivity, displaying Battery Status Icon and Voltage Indicator for 10s.
Unit Responses to Clamp Connections:
- Proper Connection: Beep, LCD displays Battery Status Icon, Voltage Indicator, Clamp Icons, +/- signs, and flashing Jump Starter Icon. Unit stays on until clamps are disconnected.
- Clamps Touch Each Other: LCD displays Battery Status Icon, Voltage Indicator. Clamp Icons, +/-, and Alarm Icon flash. Unit sounds a 2-second warning every 10 seconds until clamps are separated.
- Reverse Polarity: LCD displays Battery Status Icon, Voltage Indicator, Clamp Icons. Alarm Icon, +/-, and Reverse Polarity Icons flash. Unit sounds a continuous warning until clamps are disconnected.
- Unit Charging: Backlight on for 10s. LCD displays Battery Status Icon and Voltage Indicator. Battery Status Icon bars fill from bottom to top.
Note: The unit automatically powers off when all functions are turned off.
Viewing Battery Status
The LCD screen indicates battery charge level:
- Four solid bars: Full capacity.
- Two or three solid bars: Partially charged.
- One solid bar: Nearly empty; recharge required.
- Four blank bars: Completely empty; unit MUST be recharged. Low voltage protection will activate, and the unit will shut down.
Charging/Recharging
Lead-acid batteries require periodic charging. Recharge the unit at least every 30 days and after each use to maintain battery life.
IMPORTANT CHARGING NOTES:
- Charge for 20 hours or until the Battery Status Icon shows 4 solid bars before first use.
- Recharging after each use prolongs battery life.
- Turn off all other unit functions during recharging.
CAUTION: Failure to keep the battery charged will cause permanent damage.
IMPORTANT: If the battery icon shows full charge but the unit is discharged, it may indicate high internal battery impedance. Charge for 20 hours.
Procedure for Charging
- Connect the AC charging adapter to the unit's AC charging port and plug into a standard 120V AC outlet.
- The LCD screen will display charging indicators. The Battery Status Icon bars will fill repeatedly.
- Charge for approximately 20 hours or until 4 solid bars are shown.
- Disconnect the AC adapter when charging is complete.
Wireless Charging
The built-in Wireless Charging feature is compatible with most wireless charging devices.
CAUTION: Do not use Jump-Starter or Compressor while using Wireless Charging. Place the appliance in the center of the pad.
IMPORTANT NOTE: Wireless charging will shut down automatically if no device is detected for 3 minutes.
Procedure for Wireless Charging
- Press the Wireless Charging Button. A beep will sound, and the LCD will indicate the function is ready.
- Place the appliance on the center of the Wireless Charging Pad.
- Press the Wireless Charging Button again to turn off the feature when charging is complete.
IMPORTANT: Turn off Wireless Charging when recharging or storing the unit.
Jump-Starter
IMPORTANT: All features must be OFF (except the area light) when jump-starting. Keep the unit upright.
WARNING: Follow all safety instructions. Incorrect clamp connection will trigger an alarm and polarity error indicators. Never touch red and black clamps together. Overheating will activate thermal protection, indicated by flashing alarm and jump starter icons; allow unit to cool.
PROCEDURE:
- Turn off vehicle ignition and all accessories. Place vehicle in park and set the emergency brake.
- Connect the Boost Cables Connector to the unit's Clamp Connection Slot.
- Connect the red clamp to the vehicle's positive (+) terminal.
- Connect the black clamp to the vehicle's chassis or a solid, non-moving metal part (for negative ground systems). Refer to the vehicle's owner's manual.
- For positive ground systems, connect the black clamp to the negative (-) terminal and the red clamp to the chassis.
- Ensure clamps are properly connected (LCD will indicate readiness).
- Turn on vehicle ignition and crank the engine in 5-6 second bursts.
- Once the engine starts, disconnect the negative (black) clamp first, then the positive (red) clamp.
NOTE: If the unit malfunctions after jump-starting, recharge it with the AC charger to reset.
IMPORTANT: Detach and store the Boost Cables Connector when not in use. Turn the unit off and recharge after each use.
CAUTION: Store clamps in a dry, safe location. Be aware of vehicle computer system compatibility. Excessive cranking can damage the starter motor; discontinue if the engine fails to start. Contact a technician if the vehicle does not start.
Alternator Check
Set up the unit and connect battery clamps as per the Jump-Starter procedure.
IMPORTANT NOTES:
- The unit may detect alternator voltage range issues due to accessory loads. Ensure the alternator is rated for the application.
- This check is for 12-volt systems only and may not be accurate for all vehicles.
Procedure (No Load - Accessories OFF):
- Ensure the vehicle battery is fully charged. Run the engine to achieve normal idle speed.
- Press the Alternator Check Button. The LCD will indicate analysis.
- If the alternator is good, the LCD will display "ALT GOOD".
- If the alternator is out of range, the LCD will display "ALT" and the Fault Icon will flash.
- Press the Alternator Check Button again to stop the test.
Procedure (Under Load - Accessories ON):
- Turn on as many accessories as possible (except A/C and Defrost).
- Press the Alternator Check Button. The LCD will indicate analysis.
- If the alternator is good, the LCD will display "ALT GOOD".
- If the alternator is out of range, the LCD will display "ALT" and the Fault Icon will flash.
- Press the Alternator Check Button again to stop the test.
IMPORTANT: Turn the unit off when not in use and recharge fully after each use.
Portable Compressor
The 12-volt DC compressor is suitable for vehicle tires, trailer tires, and inflatables. It can inflate up to 120 PSI.
CAUTION: When the compressor operates at low PSI, it may start slow and gradually increase speed. At higher PSIs, it may cycle between normal operation and lower speed to prevent overheating. Do not operate continuously for longer than 10 minutes. If longer operation is needed, turn the unit off for approximately 30 minutes between cycles. The compressor will automatically shut down after 10 minutes of continuous operation.
Inflating Tires or Products with Valve Stems
- Screw the Sure Fit® nozzle onto the valve stem. Do not overtighten.
- Press the Compressor Power Button. The LCD will display the preset pressure and current pressure.
- Use the (+) and (-) Pressure Control Buttons to set the desired pressure (3-120 PSI). The unit beeps with each press. Holding the button speeds up the value change. The selected pressure is stored.
- Press the Compressor Power Button again to begin inflating. The Compressor Icon will flash, and the LCD will show the current pressure.
- Monitor the pressure on the LCD screen. Press the Compressor Power Button to interrupt inflation.
- The compressor will stop automatically when the desired pressure is reached.
- Press the Compressor Power Button again to turn off the unit.
- Unscrew and remove the Sure Fit® nozzle.
- Allow the unit to cool, then recharge before storing.
- Store the compressor hose and nozzle in the storage groove.
Inflating Other Inflatables Without Valve Stems
- Use the nozzle adapter. Screw it into the Sure Fit® nozzle.
- Insert the nozzle adapter into the item to be inflated.
- Follow steps 2 through 4 of the "Inflating Tires or Products With Valve Stems" section.
- IMPORTANT: Small items inflate rapidly. Be careful not to over-inflate.
- When desired pressure is reached, the compressor stops automatically. Press the Compressor Power Button to turn off the unit.
- Disconnect the adapter from the item.
- Unscrew and remove the nozzle adapter from the Sure Fit® nozzle.
- Allow the unit to cool, then recharge before storing.
- Store the compressor hose, Sure Fit® nozzle, and nozzle adapter in the storage groove.
USB PORTS
The USB Power Button and two USB Ports are located on the front of the unit. USB Power/Fault Indicators are rings around each port.
IMPORTANT NOTES:
- The two USB Ports provide a total of 3.1A (5V each).
- The unit monitors for USB fault conditions: low battery voltage, overload, and short circuit.
- Low Battery Voltage Fault: USB Power/Fault Indicators turn off. LCD displays Battery Status Icon and Voltage Icon for 10s before shutdown.
- Overload/Short-Circuit Fault: USB Power/Fault Indicators flash blue. LCD displays Fault Icon flashing. Unit shuts down.
- If a fault occurs: Disconnect the USB device, press the USB Power Button to turn off ports, ensure the unit is charged, and allow it to cool. If the fault persists with a compatible device, have the device checked.
- USB Ports provide power only; they do not support data communication.
- Some household USB electronics may not operate with this unit.
Using the USB Ports
- Press the USB Power Button to turn on both ports. A beep sounds, indicators light blue, and the LCD displays the Battery Status Icon, Voltage Icon, and USB Icon.
- Plug the USB-powered device into a port and operate normally.
- Press the USB Power Button again to turn off the USB Ports.
Periodically check the unit's battery status. Recharge if the battery level is low (one solid bar or empty).
IMPORTANT: Ensure USB Ports are OFF when recharging or storing the unit.
LED Area Light
The built-in LED Area Light is controlled by the area light on/off button.
- Press the Area Light Power Button once to turn the light ON.
- Press the button again to turn the light OFF.
When turned ON, a beep sounds, and the LCD backlight turns on for 10 seconds.
IMPORTANT: Ensure the Area Light is OFF when recharging or storing the unit.
Care and Maintenance
- Recharge the unit at least every 30 days when not in use.
- Wipe the exterior with a soft cloth. Do not immerse in water.
- There are no user-replaceable parts. Periodically inspect adapters, connectors, and wires. Contact the manufacturer for replacement of worn or broken components.
Battery Replacement/Disposal
The battery is designed to last the service life of the unit and is not user-replaceable.
SAFE BATTERY DISPOSAL: Contains a sealed, non-spillable lead-acid battery. Recycling is required. Failure to comply with regulations may result in fines.
WARNING:
- Do not dispose of the battery in fire; it may explode.
- Protect exposed terminals with heavy-duty electrical tape before disposal to prevent shorting.
- Do not expose the battery to fire or intense heat.
Troubleshooting
Problem | Possible Solution |
---|---|
Unit not charging |
|
Wireless Charging function will not charge appliance |
|
Engine fails to jump-start |
|
Portable Compressor will not inflate |
|
USB Power Port will not power appliance |
|
LED Area Light does not come on |
|
Accessories
Recommended accessories may be available from the manufacturer. Contact 1-877-571-2391 for assistance. WARNING: Using unrecommended accessories can be hazardous.
Service Information
For technical advice, repair, or genuine factory replacement parts, contact the manufacturer at 1-877-571-2391.
Two-Year Limited Warranty
The manufacturer warrants this product against defects in materials and workmanship for TWO (2) YEARS from the date of retail purchase. If a defect is found within the warranty period, the product may be replaced or repaired at the manufacturer's option. Proof of purchase may be required. Returns to retailers are subject to the retailer's return policy (usually 30-90 days). This warranty does not cover accessories, bulbs, fuses, batteries, normal wear and tear, accidents, shipping damage, unauthorized alterations or repairs, neglect, misuse, abuse, or failure to follow care instructions. This warranty grants specific legal rights which may vary by state or province. This product is not intended for commercial use.
Appendix: FCC Statement
This device complies with Part 15 and Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 and Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During operation, maintain a distance of 15 cm surrounding the device and 20 cm above the top surface of the device.
This device complies with Part 18 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Increase the separation between the equipment and any other radio device.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Specifications
Specification | Details |
---|---|
Boost Ampere | 1,000A peak, 350A instant |
Battery Type | SLA, 12V DC |
Input | 120V AC, 60Hz, 14W |
Compressor | 120 PSI (max.) |
USB Output | 5V DC each, 3.1A (max.) |
Wireless Charging | 10W (max.) |
Sure Fit® is a registered trademark owned by Baccus Global, LLC.
Imported by Baccus Global LLC, 621 NW 53rd St., Suite 450, Boca Raton, FL 33487