WISI OH 50 A COMPACTHEADEND Basic Unit

Operating Instructions

Product Overview

The WISI OH 50 A COMPACTHEADEND is a basic unit designed for analogue and digital TV signals. It features slots for up to 14 modules, supports 19" rack mounting and wall mounting, includes an integrated FM amplifier, and offers easy programming via the OH 41 handset. Updates can be performed via USB memory stick, and the unit can be connected via Ethernet LAN for HTTP web browser access. Alarms and warnings can be received via e-mail.

Note: Disconnect the OH 50 A mains power before installing modules!

Included in scope of delivery: Wall mounting bracket, 19" installation kit.

Safety and Installation Notes

Connectors

Connector Description
RF out RF output; sum signal from the modules for injection into the distribution system.
TP -20 Test output -20 dB.
FM in Input FM amplifier, 25 dB.
LED "Status" Global alarm status display showing alarm level of all OH modules. Blinks during communication. Color indicates module status (green: ok, red: alarm, yellow: first scan). Flashes red in bootloader mode.
LED "Power" Status depends on OH50A temperature and power input of all modules (green: ok, yellow: warning, red: alarm).
LAN Interface to connect the unit to an Ethernet network for remote control.
Backside: AC 230V Mains connection.
Potential equalization terminal Potential equalization terminal.
USB update interface USB update interface.

Mounting Options

Wall Mounting

For wall mounting of the OH50 chassis, use the supplied angle brackets and screws (M4x6). Fix brackets on both sides.

Wall Mounting Versions:

19"-Rack Mounting

For 19"- rack mounting, use the supplied angle brackets and screws (M4x6). Fix brackets on both sides.

Mounting 19" angle brackets:

Dust protection cover: To protect the basic unit during mounting, leave the carton as a cover at the front of the housing.

Recommendation and Short Circuit Behavior

Handset OH 41 (Accessory)

The OH 41 handset is used for programming and system menu access.

Standby: After mains connection and module initialization, plug the handset into the basic unit socket. Press the [Enter Key] to enter the module menu and system menu.

Modul menu: Navigate through modules (1-14) and parameters using the navigation keys (⬆️, ⬇️, ⬅️, ➡️).

Parameter menu: Select and adjust parameters.

Parameter sub-menu: Select and change digits within a parameter value.

Saving data: Data are saved automatically after leaving the parameter menu or 60 seconds after the last entry.

Initializing the modules:

Detailed menu structures are found in the related module manual.

System Menu of the Basic Unit

The "System settings" menu allows parameter setup of the basic unit. Accessing "System settings" provides the following parameters:

Navigating back from "System settings" to the module selection menu and pressing the [Enter Key] button immediately moves the device to standby.

Saving changes: Changes are saved by leaving the "System settings" menu. If no user setting is made, the standby display appears after 60 seconds, and settings are not stored.

Update Functions (Basic Unit and Modules)

System Recovery

Press the [Up Key] and [Down Key] buttons simultaneously when power is applied. Then press the [Enter Key] button and choose Backup SW "yes" to start emergency application.

Update Functions in the OH 50A menu "system settings"

Required steps for software update:

  1. Connect handset to the base unit (must display standby message).
  2. Plug a USB memory stick into the USB port.
  3. Select one of the following options:
    • Multiupdate Mod: Automatically updates all modules with newer software from the USB stick.
    • Update OH 50A: Updates only the base unit. Ensure the file name "OH50A_HW_Vx_xx_SW_Vx_xx.bin" is unique on the USB stick.
    • Cfgload: Uploads configuration settings from a file on the USB memory stick to the modules. Module types and slot order must match the configuration file.
    • Cfgsave: Uploads the current module configuration to the USB memory stick (e.g., Config.OH50A_2014_05_01_14_15).

If a module update fails, it remains in bootloader mode, indicated on the web interface and handset. The module can be reprogrammed via the web interface or by selecting "Multiupdate Mod." in the "System Settings" menu via handset.

Update Precautions

Activation of the OH51A remote monitoring function

The UID (Unique ID) of the device is required to activate the OH51A remote monitoring function. The UID can be found on the type and packaging label.

System Configurations Example

The WISI COMPACT HEADEND processes analogue and digital TV programmes in networks.

Adjusting the system levels: The output level must always be set to the permissible system output level. The output level for each module can be adjusted via the "Out-Att" parameter menu.

Default Factory IP Parameter Values and SNMP Community Strings

Parameter Value
IP address 192.168.0.20
Netmask 255.255.255.0
Gateway 192.168.0.1
DHCP disabled (DHCP functionality is disabled)
E-Mail disabled
HTTP Port 80 (standard)
SNTP disabled (time synchronisation server disabled)
Sync Install Time 24 (time synchronisation all 24 hours)

OH-Setup Windows Tool

The WISI tool "WISI OH-Setup" (filename 'OHSetup.exe') requires Windows XP/7 and an Ethernet connection to the OH50A unit. Start the program and complete the fields with the correct Ethernet MAC Address (from OH rack label) and desired IP parameters (IP-Address, Network mask, Gateway).

Press "Assign" to set parameters. The tool verifies IP validity and availability before storing them. Check the status line for success.

OH 41 Handset Priority

While the handset is in use (Modul Menü), the web interface is disabled ("Handset in use"). After 60 seconds, the handset returns to standby, and the web interface is re-enabled. The handset has higher priority.

Activation of the Web Interface

The Web UI of the OH 50 A is locked by default. After logging in as "user", a message prompts to contact a WISI distributor for a license key using the device's UID. WISI converts the UID into an unlock code for a fee. Entering this code permanently unlocks the device.

Web Interface

An Ethernet connection between a PC (with a web browser) and the OH50A unit is required.

Recommended Web Browsers:

Setup via Web Interface:

  1. Know the current IP address of the OH50A module. Setting the address is possible with the handset.
  2. Read/Write Access: Log in as "user" with password "wisi" (factory setting).
  3. Read Only Access: Log in as "read" (no password needed).
  4. Select the "Network settings" tab under "OH50A".
  5. If IP parameter changes are needed, press "save". The browser redirects to the new address.

Web Interface Tabs:

Specifications

Booster amplifier

Parameter Value
Frequency range TV 47–862 MHz
Frequency range FM 87.5–108 MHz
Output impedance 75 Ω
Output return loss > 14 dB
Output level 110 dBμV
Output attenuator 0-15 dB / 1 dB steps
Input level (FM) 70–100 dBμV
FM attenuator 0-30 dB / 1dB steps
CTB > 60 dB
CSO > 60 dB
Test output -20 dB

Power supply

Parameter Value
Input voltage 180... 265 VAC (47... 63 Hz)
Max. power consumption < 185 W
Efficiency ≤ 89%
Output voltage 12.5 V
Output current 12 A
LNB power 12.5 V, 1.2 A
PFC EN 61000-3-2

Ethernet ("LAN")

Parameter Value
Interface 10/100 Base-T, RJ-45 female jack
2 Leds green for link/activity, yellow for speed
Protocol Data Link Layer: Ethernet
Network Layer: IP, ICMP
Transport Layer: UDP, TCP
Application Layer: DHCP (for automatic IP address assignments), (UDP Port 123, for time and date synchronisation), SNTP, RFC 4330 HTTP (web server access)
Speed 10/100 Mbps
Duplex half-duplex/full-duplex, autosensing
IP Version 4

Remote Bus (OH backplane, communicates with all connected OH modules)

Parameter Value
Interface board connector, 20 pins, RS-485
Protocol Module ASCII
Speed 115 kbaud
Duplex half-duplex

General Specifications

Parameter Value
Dimensions 443 (19") x 132 (3HU) x 351 mm
Connectors FM-input: 1 x F-connector
RF-output: 1 x F-connector
Test-output: 1 x F-connector
Handset control: RJ 11
Software update: USB-A
Remote connection: RJ 45
Operating temperature range -20 °C to + 50 °C
Nominal temperature range +5 °C to +50 °C

PDF preview unavailable. Download the PDF instead.

14mm-oh50a instructions Adobe InDesign CC (Windows) Adobe PDF Library 11.0

Related Documents

Preview WISI COMPACT HEADEND OH 50 A Operating Instructions and Technical Specifications
Comprehensive operating instructions and technical specifications for the WISI COMPACT HEADEND OH 50 A unit, covering installation, setup, operation, updates, and troubleshooting.
Preview WISI PROSWITCH DY 40 Line Amplifier - Operating Manual
Comprehensive operating manual for the WISI PROSWITCH DY 40 line amplifier, detailing its features, installation, programming, and technical specifications for satellite IF signal distribution.
Preview WISI LRPS A230 Plug-in Power Supply - Operating Instructions and Technical Data
Comprehensive operating instructions and technical specifications for the WISI LRPS A230 plug-in power supply, designed for the WISI LR10 IN HOME FIBER TERMINATION. Learn about safe usage, product features, and proper disposal.
Preview WISI EE 06 & EE 06 A UHF Broadband Antenna Mounting Instructions
Comprehensive mounting and technical data for WISI EE 06 and WISI EE 06 A UHF broadband antennas, covering installation steps and specifications.
Preview WISI FLEXSWITCH DRC 09xx Series: Satellite Multiswitch Operating Manual
Operating manual for the WISI FLEXSWITCH DRC 09xx series multiswitches, detailing features, installation guidelines, application examples, and technical specifications for satellite and terrestrial signal distribution.
Preview WISI FLEXSWITCH DRC 17xx Multiswitch: Operating Manual and Technical Specifications
Detailed operating manual and technical specifications for the WISI FLEXSWITCH DRC 17xx series multiswitches, covering features, installation guidelines, application examples, and comprehensive performance data for satellite and terrestrial signal distribution.
Preview WISI OE 01 Encoder Modulator: HDMI to RF Conversion Manual
Comprehensive guide to the WISI OE 01 Encoder Modulator, covering installation, configuration, safety, and technical specifications for converting HDMI signals to DVB-C/T, ATSC-T/C, and DTMB RF outputs.
Preview Руководство пользователя WISIon: Интерактивная IPTV система для гостиниц
Подробное руководство пользователя от WISI, описывающее систему WISIon — комплексное решение для организации интерактивного IPTV вещания и цифровой рекламы в гостиничном бизнесе. Узнайте о функциях, модулях, установке и настройке системы для улучшения услуг для гостей.