JURA X4 (EA/SA/INTA) Technical Documentation
Requirements for installation location
- Horizontal surface that is not sensitive to water
- Ambient conditions:
- Air humidity max. 80%
- Ambient temperature 10–35°C
Note: The required connections at the customer's premises must be carried out by an approved qualified person before the JURA service technician can set up the machine at your chosen location.
Note: Please make sure that the building connections are as close as possible to the location of the machine (refer to length of connection pipes).
Always note the information in the instructions for use for your coffee machine (Chapter “Setting up the machine”).
Dimensions
Front View:
Width: 373 mm
Height: 470 mm
Depth: 484 mm
Side View:
Width: 464 mm
Height: 470 mm
Depth: 201 mm
Side View (with drip tray extended):
Height: 400 mm
Side View (dimensions related to connections):
Height: 63-150 mm
Height: 58.4 mm
Height: 119.6 mm
Back of the machine
Connections and Drains:
Drain hose connection point: 204 mm from the left edge, 22 mm from the bottom edge.
Total width of the back panel: 243 mm
Note: 1 Position of drain hose.
Position of hole in work surface for coffee grounds disposal
Diagram Description: A diagram shows the top surface of a work area with a circular cutout for coffee grounds disposal.
Dimensions for Cutout:
- Hole diameter: minimum 70 mm
- Position from front edge: 201 mm
- Position from left edge: 180 mm
- Position from right edge: 193 mm
- Total depth of the work surface shown: 263 mm
Note: 2 Position of tube section for coffee grounds disposal.