Rossmax PF120 Peak Flow Meter

Rossmax PF120 Peak Flow Meter

Model: PF120 A, PF120 C

Manufacturer: Rossmax

Website: www.rossmax.com

Introduction

The Rossmax Peak Flow Meter is used to measure peak expiratory flow rate (PEFR), an important indicator of your lung function. The Peak Flow Meter should be used for monitoring respiratory conditions such as asthma. Taking peak flow measures every day and keeping a record of the peak flow measures in your "peak flow diary" can help you and your physician make important decisions about your treatment. You should use this meter and set its color zone indicators according to a treatment plan developed for you by your physician. Please download the peak flow record chart at our website www.rossmax.com. It is important to keep your peak flow meter clean when in use.

Attention: Consult the accompanying documents. Please read this manual carefully before use. For specific information on your own PEFR, contact your physician. Please be sure to keep this manual.

How to Use

  1. Set red indicator to bottom of scale.
  2. Stand up, take a deep breath, place your mouth around the peak flow meter and hold it horizontally, your lips form a tight seal.
  3. Blow the air out as hard and as fast as possible. The number where indicator stops is your peak measurement.

Note: Coughing and spitting into the meter will adversely affect your reading and should be avoided.

Repeat the steps 1, 2, 3 twice more to obtain three readings. Record the highest reading in your daily record chart.

Troubleshooting

Examine peak flow meter regularly to make sure it is working properly. The moving parts should function smoothly and freely and indicator should remain in place when moved to a position of scale. If unusual readings are obtained, consult your doctor. Please contact Rossmax service if necessary. With proper care, avoid crushing and keep it clean and dust free, your peak flow meter should last at least one year and up to three years, suggest replacing a new unit.

Cleaning and Disinfection

Clean at least once every week by immersing peak flow meter in warm (but not hot) mild detergent water solution for 2-3 minutes (max 5 minutes). Agitate the meter to ensure through cleaning. Rinse in clean warm water and shake gently to remove any excess water and air dry completely before using again.

Do not boil meter for disinfect.

Caution

Using a peak flow meter to monitor respiratory condition such as asthma should be under the care of physician. A peak flow meter is intended for single patient use unless it is cleaned thoroughly after each use and disposable mouthpieces are used. Mouthpieces are available.

How to Record Your Peak Expiratory Flow Rate

This meter was designed to make following your asthma treatment plan easy. Your doctor will set the color zone indicators to your personalized zones based on your personal best peak expiratory flow rate value (the best peak flow value you can achieve).

Note: Do not change the position of the color zone indicators yourself. If this should occur inadvertently, contact your doctor or specialist nurse for advice.

Reading should be taken twice a day, first in the morning and at bed time, or directed by your physician. When you blow into your peak flow meter, the indicator will rise to your peak flow value. Your peak flow measurement will fall into one of three zones.

Color Zones:

  • Green: Follow your regular medication plan, and go ahead with normal activities (80-100% of best reading).
  • Yellow: Caution, your asthma might be worsening. Follow your medication instructions to get back to your green zone (50-80% of best reading).
  • Red: Medical alert, get medical advice and attention immediately (< 50% of best reading).

Specifications

FeatureDetails
Measurement RangePF120 A: 60-800 L/min BTPS
PF120 C: 50-400 L/min BTPS
Accuracy± 10 L/min or ± 10% of reading (whichever is greater)
Repeatability± 5 L/min or ± 5 % of the reading (whichever is greater)
Storage Condition10-35 °C, 30-75% RH
Max resistance0.00384 kPa/L/min@ 720 L/min
Altitude effects on the Peak Flow Meter (and on the expired air)Lowers readings by approx. 5% per 1000m, (decreased air density increases PEF by approx. 5% per 1000m)
Frequency responseProfile A/B difference less than 15 L/min or 15% (whichever is greater)

Warranty Card

This instrument is covered by a 2-year guarantee from the purchase date. The guarantee is valid only on presentation of the guarantee card completed by the dealer confirming date of purchase or the receipt. Opening or altering the instrument invalidates the guarantee. The guarantee does not cover damage, accidents or non-compliance with the instruction manual. Please contact your local seller/dealer or www.rossmax.com.

Customer Name: ________________________________________________________

Address: _____________________________________________________________

Telephone: ___________________________________________________________

E-mail address: _________________________________________________________

Product Information

Date of purchase: _______________________________________________________

Store where purchased: ____________________________________________________________________

Manufacturer: Shanghai Everpure Medical Plastic Co., Ltd. No. 2418 Tingfeng Rd., Xinnong Town, Jinshan District, 201503 Shanghai, China

Distributor: CMC Medical Devices & Drugs S.L. C/ Horacio Lengo N°18, CP29006, Málaga, Spain

Models: PF120 A, PF120 C, PF120 Series Peak Flow Meter, Peak Flow Meter, Flow Meter, Meter

File Info : application/pdf, 2 Pages, 527.10KB

PDF preview unavailable. Download the PDF instead.

OBM IB PF120AC V9 SHEP

References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Windows)

Related Documents

Preview Rossmax HS200 Blood Glucose Monitoring System User Manual
Comprehensive guide to the Rossmax HS200 Blood Glucose Monitoring System, covering setup, testing, troubleshooting, specifications, and safety for accurate blood glucose management. Visit www.rossmax.com for more information.
Preview Rossmax NE100 Compressor Nebulizer User Manual
Comprehensive user manual for the Rossmax NE100 Compressor Nebulizer, covering setup, operation, cleaning, maintenance, troubleshooting, and specifications.
Preview Rossmax NA100 Piston Nebulizer: Instruction Manual & User Guide
Comprehensive instruction manual for the Rossmax NA100 Piston Nebulizer. Learn how to operate, clean, assemble, and troubleshoot your device for effective respiratory therapy.
Preview Rossmax CF155f Blood Pressure Monitor User Manual
Official user manual for the Rossmax CF155f digital blood pressure monitor. Provides detailed instructions on setup, operation, measurement procedures, troubleshooting, and technical specifications for accurate home health monitoring.
Preview Rossmax Z1 Automatic Blood Pressure Monitor User Manual
This document provides instructions for using the Rossmax Z1 Automatic Blood Pressure Monitor, including setup, operation, troubleshooting, and technical specifications. It covers features like Real Fuzzy Technology, Cuff Wrap Detection, Movement Detection, Hypertension Risk Indication, and Irregular Heartbeat Detection.
Preview Rossmax CH155 Automatic Blood Pressure Monitor | Accurate Home Health
Discover the Rossmax CH155 Automatic Blood Pressure Monitor, designed for accurate and convenient home health monitoring. Features include Movement Detection, Real Fuzzy Technology, Hypertension Risk Indication, Irregular Heartbeat Detection, and clinically validated accuracy by ESH and BIHS.
Preview Rossmax HA500 Non-Contact Temple Thermometer User Manual
Comprehensive user manual for the Rossmax HA500 non-contact temple thermometer, detailing features, operation, troubleshooting, and specifications for accurate body temperature measurement. The device is designed for accurate human body temperature measurement and complies with relevant medical device directives.
Preview Rossmax HC700 Non-Contact Temple Thermometer User Manual
Comprehensive user manual for the Rossmax HC700 non-contact infrared thermometer, detailing its features, operation, troubleshooting, and specifications for accurate body and object temperature measurement.