Pro Induction Ranges
This document provides design and installation specifications for Wolf's New Pro Induction Ranges.
Models Available:
- IR30451/S/P
- IR36551/S/P
- R48751/S/P
Dimensional Specifications:
Key dimensions for the Wolf Pro Induction Ranges are as follows:
30" Range:
Overall Width: Approximately 30 inches (762 mm).
Depth: Approximately 26 7/8 inches (683 mm).
Height: Adjustable, ranging from 35 1/2 inches (902 mm) MIN to 38 inches (965 mm) MAX.
36" Range:
Overall Width: Approximately 36 inches (914 mm).
Depth: Approximately 26 7/8 inches (683 mm).
Height: Adjustable, ranging from 35 1/2 inches (902 mm) MIN to 38 inches (965 mm) MAX.
48" Range:
Overall Width: Approximately 48 inches (1219 mm).
Depth: Approximately 26 7/8 inches (683 mm).
Height: Adjustable, ranging from 35 1/2 inches (902 mm) MIN to 38 inches (965 mm) MAX.
Planning Information:
Maintain minimum clearances to combustible surfaces as indicated in installation diagrams. For 48" (1219) models, two separate electrical supplies are required. Position receptacles with grounds facing each other to prevent cord interference.
Electrical Requirements:
Installation must adhere to all applicable electrical codes. Locate the electrical supply flush with the wall or floor. A dedicated circuit for this appliance is required. If a power supply cord is used, it must be rated for 240 V, 50 amps, and include 3 or 4 conductors. A 4-conductor cord is necessary if grounding through the neutral is prohibited.
CAUTION: Risk of electric shock. If the cord or plug is damaged, disconnect the appliance from the power supply and replace it only with a cord or plug of the same type.
Performance may be compromised if the electrical supply is less than 240 volts.
IMPORTANT NOTE: Two separate electrical services are required for 48" (1219) models.
ELECTRICAL REQUIREMENTS | Details |
---|---|
Electrical Supply | Grounded, 240/208 VAC, 60 Hz |
Service* | 50 amp dedicated circuit |
* Two services required for 48" (1219) models.
Refer to the appliance's rating plate for specific electrical information.
Installation Clearances and Opening Dimensions:
Proper installation requires adherence to specific clearances and opening sizes:
Clearances:
- 2 inches (51 mm) from appliance to wall.
- 13 inches (330 mm) clearance to combustible surfaces.
- 18 inches (457 mm) clearance to the bottom of a ventilation hood.
- Combustible materials must not be located within the shaded area above the countertop, which indicates minimum clearance to combustible surfaces.
- For island installations, maintain a 12-inch (305 mm) minimum clearance from the back of the range to the combustible rear wall above the countertop.
Opening Width and Depth Requirements:
Range Size | Opening Width (W) | Depth (A) |
---|---|---|
30" Range | 30 inches (762 mm) | 10 1/4 inches (260 mm) |
36" Range | 36 inches (914 mm) | 16 1/4 inches (413 mm) |
48" Range | 48 inches (1219 mm) | 18 1/4 inches (464 mm) |
Wolf Residential Limited Warranty
This section details the warranty coverage for Wolf Appliance products used in residential applications.
Wolf Appliance Residential Warranty
For Residential Use
Full Two Year Warranty*:
This warranty covers all parts and labor for repair or replacement of defective materials or workmanship for two years from the original installation date, under normal residential use. All service must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service is provided during normal business hours.
Limited Five Year Warranty:
For five years from the original installation date, Wolf Appliance will repair or replace specific parts found to be defective in materials or workmanship. These parts include: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes, and induction generators. If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts, with the owner responsible for all other costs, including labor. If non-certified service is used, the owner must contact Wolf Appliance, Inc. to receive repaired or replacement parts. Wolf Appliance will not reimburse for parts purchased from non-certified service or other sources.
Terms Applicable to Each Warranty:
The warranty applies only to products installed for normal residential use within the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. This warranty does not cover any parts or labor to correct defects caused by negligence, accident, improper use, maintenance, installation, service, or repair.
Limitation of Liability: The remedies described are the exclusive remedies provided by Wolf Appliance, Inc. under this warranty or by operation of law. Wolf Appliance, Inc. will not be responsible for any consequential or incidental damages arising from the breach of this warranty or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty grants specific legal rights, and you may have other legal rights that vary from state to state.
Receiving Service:
To receive parts and/or service, or to find the name of the nearest Wolf Factory Certified Service provider, contact Wolf Appliance, Inc.:
- Mail: Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744
- Website: wolfappliance.com (Check the Product Support section)
- Email: customerservice@subzero.com
- Phone: 800-222-7820
*Stainless steel components (doors, panels, handles, product frames, and interior surfaces) and manufacturer-provided, powder-coated doors are covered by a limited 60-day parts and labor warranty for cosmetic defects.