Honeywell Lyric T4, T4R & T4M Programmable Thermostats

Product Specification Sheet

Product Overview

The Honeywell Lyric T4, T4M, and T4R thermostats are designed to provide automatic time and temperature control for heating systems in homes and apartments. The T4 is compatible with 24-230V on/off appliances like gas boilers, combi-boilers, and heat pumps, and also works with zone valve applications (but not electric heating at 240V). The T4M and T4R versions support OpenTherm® appliances.

The T4 and T4M are designed for wired wall installations, while the T4R is a wireless system consisting of a thermostat and a Receiver box. The solution is installer-focused, featuring a Receiver module with flexible mounting options and a terminal platform that simplifies wiring.

The thermostat boasts a large, clear fix-segment display with backlight and a simple programming philosophy, making it easy to install and user-friendly. The T4 product line is ideal for consumers seeking modern design, remote comfort control, and ease of use.

Features

Thermostat Display/Button Layout

The thermostat display shows setpoint periods, current time/timer, menu items, alert/fault status, room temperature, setpoint temperature, heat demand, and low battery status. It also indicates wireless signal strength (for T4R only) and schedule status.

Navigation is done via buttons for Menu (☰), Confirm (✖), and Cancel (✗). Other functions include Timed override (⏚), Standby mode, Home screen (⌂), and Away mode (?).

Reference to the Icons:

Receiver Box Interface

The Receiver Box features a Status LED indicating communication with the thermostat and binding mode. It also has a Manual override button and a Reset/Delete binding button.

Specifications

T4/T4M/T4R Thermostat

Parameter Details
Control form Fuzzy Logic
Room temperature display range 0 °C to 50 °C
Dimensions (w x h x d) T4/T4M: 136 x 97 x 28 mm
T4R (Wireless): 136 x 98 x 62 mm
Time display 24 hour or 12 hour AM/PM format
Time keeping accuracy +/- 10 mins per year
Program 5+2, weekly, or daily schedule with 4 or 6 daily time and temperature level changes
Time setting resolution 15 minute steps
Sensing element 10k(@25 °C) NTC thermistor
Temperature Setting range Program: 5 to 35 °C
OFF: 5 °C
Power 2 x AA batteries
Wiring T4 (wired) and T4M (OpenTherm) terminal block capable of accepting wires up to 1.5 mm²
RF communication band ISM (868.0-868.6) MHz, 1% duty cycle
Max. power 25mW
Protocol Encrypted
Comm. Range 30m in residential building environment
Comm. Technology Short, high rate transmissions to minimise air time and avoid collisions
Receiver class R.E.D. RX Cat 2 (ETSI EN300 220-1 version 1.3.1)

Receiver Box

Parameter Details
Power 230VAC
Electrical rating 230V~, 50..60Hz, 0.5A to 5A resistive; 0.5A to 3A inductive (0.6 pf)
24V~, 50..60Hz, 0.5A to 5A resistive; 0.5A to 3A inductive (0.6 pf)
Cycle rate Selectable by application (see installer set up)
Wiring Terminal block capable of accepting wires up to 1.5 mm²
Wire access From back via large wall box opening. From bottom with cable clamps. Mains wiring - left, Low voltage wiring - right.
Dimensions (w x h x d) 110 x 110 x 40 mm
IP class 30

Environmental and Standards

Parameter Details
Operating temperature range 0 to 40 °C
Shipping and storage temperature -20 to 55 °C
Humidity range 10 to 90% rh, non-condensing
EMC 2014/30/EU
LVD 2014/35/EU
R&TTE 1995/5/EC
ErP Class IV (+2%), (EU) 811/2013 (T4)
Class V (+3%), (EU) 811/2013 (T4R)
Class VI (+4%), (EU) 811/2013 (T4M)

Honeywell declares that this thermostat is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.

Installer Menu Options

To enter the Installer menu, press the ☰ button and then navigate using the +/- buttons until the display changes (approx. 3 seconds).

Specific Applications Setting What do you need to change?
Heating CpH (cycle per hour): 6
Minimum on Time (min): 1
Note:
a. To change cycle per hour
b. To change minimum ON time
No action required for Gas Boilers (30kW).
Oil Boiler CpH: 3
Minimum on Time (min): 4
a. Set minimum ON time to 4 minutes.
b. Set cycle per hour to 3.
Thermal Actuator CpH: 12
Minimum on Time (min): 1
Set cycle per hour to 12.
Zone valve CpH: 6
Minimum on Time (min): 1
No actions required.

Special Features

Feature Description
OpenTherm® By connecting the T4M to an OpenTherm® appliance, various specific data can be viewed, depending on what the appliance is providing.
Heat range The normal lower temperature limit of 5 °C can be increased up to 21 °C to protect vulnerable inhabitants (elderly, children, disabled). The normal upper temperature limit of 37 °C can be reduced down to 21 °C to save energy, useful for rental properties.
Schedule options The thermostat defaults to 5+2 schedule (weekday/weekend). It can be changed to 7-day (different schedule each day) or 1-day (same schedule every day).
External temperature sensor (only for wired versions) An external sensor can be fitted to control temperature from another room. It reads the sensor every minute and can be connected up to 50 meters away. Useful for public areas where tampering might occur.
Optimisation (optimum start, optimum stop and delayed start) Optimum Start: Learns how long the system takes to reach the desired temperature and turns heating on earlier to ensure comfort at the scheduled time.
Optimum Stop: Saves energy by switching off slightly earlier than programmed if the home is already at temperature.
Delayed start: Saves energy by slightly delaying heating start based on the difference between scheduled and actual room temperature.
Clock setting Change display format (default 24hr) and adjust time and date.
Temperature offset If the thermostat is in a hot/cold location, the displayed temperature can be adjusted by +/- 1.5 °C to match other appliance displays.
Binding (only for T4R) Menu to bind the Thermostat and Receiver box, test RF signal strength, and clear existing bindings.
Reset Resets the thermostat to factory default settings and restores the schedule to default.
Failsafe If the temperature sensor fails (T4, T4M) or wireless communication is lost (T4R), the device cycles the demand 20% On / 80% Off.

Menu Item Settings

Menu item Default What do you need to change?
1LA: Language 1=English 1=English, 2=Dutch, 3=French, 4=German, 5=Spanish, 6=Italian
2CR: Cycle rate 6 3,6,9,12
3OT: Min on time 1 1,2,3,4 or 5 minutes
4LL: Lower Temperature 5 5 °C to 21 °C
5UL: Upper Temperature 25 21 °C to 35 °C
6SO: Schedule options 5+2 1= 7 day (different schedule each day of the week)
2= 5+2 (weekday + weekend schedule)
3= 1 day (same schedule every day of the week)
7NP: Number of periods 4 4 or 6 number of heating periods per day
9LC: Fail safe mode 0 0= Deactivated
1= Activated
10BL: Backlight 1 0= Deactivated
1= Activated (only on demand)
11CL: Clock format 0 0= 24h
1= 12h (AM/PM)
12DS: Daylight saving time change 1 0= Deactivate Daylight saving time change
1= Automatically change time during DST
13TO: Temperature offset 0 -1.5 °C to + 1.5 °C
15SD: Restore schedule 0 1= Reset the default schedule
16FS: Restore factory settings 0 1= Reset the device to factory settings

Dimensions

T4, T4M Thermostat: 136 mm (width) x 97 mm (height) x 28 mm (depth). Weight: 260 grams.

T4R Thermostat: 136 mm (width) x 98 mm (height) x 62 mm (depth). Weight: 260 grams.

Receiver Box: 110 mm (width) x 110 mm (height) x 40 mm (depth). Weight: 200 grams.

Installation

Safety First: Always ensure mains power is switched OFF before accessing wiring. Before removing an old thermostat, take a picture of its wiring as a reference.

Thermostat Placement: The T4 thermostat should not be placed near draughts, in direct sunlight, or near heat sources. It should be mounted at least 1.2 - 1.5 meters from the floor.

Prepare Receiver Box (T4R only)

Needed during installation:

Location: Find a suitable location near the boiler, at least 30cm away from any metal objects, including wall boxes and boiler housing.

Accessing Terminals: Loosen the front screw to remove the cover or tighten it when the cover is back in position.

Install Receiver Box (T4R only)

A. Wall box or Rear wiring: Hinge open the terminal block flap to access the cables and wall box screw holes.

B. Surface wiring: Hinge open the terminal block flap to access the cables and wall box screw holes.

C. Replace cover: Locate the hinges at the top of the cover and wall plate, close the cover, and secure with the screw.

Complete Installation (T4R)

Turn mains power ON to the heating application and the receiver box. After powering up, the status LED on the Receiver Box should be steady GREEN (?). Press the manual override button to check if the boiler switches ON. The button LED lights should turn GREEN (?).

Install Thermostat (T4 and T4M only)

A. Wall plate: Using a screwdriver, open the wall plate terminal cover to connect wires.

B. Surface wiring: Connect wires according to wiring diagrams and clip the cover closed.

C. Place thermostat: Attach the thermostat to the wall plate when finished.

Power Up the Thermostat (T4 and T4R only)

Remove the battery tab and clip the thermostat onto the wall-plate.

Setup and Configuration

After power up, the language selection is displayed on the thermostat's screen. Press +/- to select language and ☰ to confirm.

Then, press +/- to set date, time, and clock format, and ☰ to confirm.

BINDING (T4R only)

The T4R thermostat wireless kit comes pre-bound from the factory. Binding is only required if the T4 thermostat or Receiver box is replaced, or if binding data is incorrect or missing.

To bind/rebind:

  1. Reset Receiver Box: If the Receiver box has been bound before, press the pinhole with a small pin for approximately 3 seconds to reset binding. LEDs will flash amber momentarily.
  2. Put Receiver box into binding mode: Press the button for 3 seconds. The LED will flash amber.
  3. Enable binding on thermostat: Enter the binding menu by pressing and holding the ☰ button for 3 seconds, then press the - button. Change parameter 14A to 1 and press ☰ to confirm.
  4. Successful binding: The [Wi-Fi symbol] icon will appear on the thermostat's screen. The Receiver box status LED will show steady green.

Wiring Diagrams

The following diagrams illustrate wiring configurations for different boiler types and thermostat models. It is recommended to consult a qualified installer for electrical work.

Wiring (T4 and T4M only)

Basic 230V Boiler: Connects the thermostat to a basic 230V boiler. Includes connections for permanent live (if required), L, N, and thermostat terminals (A, B, C, T, S).

Combi-Boiler: Connects the thermostat to a combi-boiler. Similar terminal connections as basic boiler.

2-Port Zone Valve: Connects the thermostat to a 2-port zone valve system (e.g., V4043). Includes connections for L, N, and thermostat terminals (A, B, C, T, S), with a connection to the zone valve.

OpenTherm Boiler: Connects the T4M thermostat to an OpenTherm boiler. Features polarity-free connections for OpenTherm communication.

Wiring (T4R only)

Basic 230V Boiler: Connects the Receiver Box to a basic 230V boiler. Includes connections for 230V power (L, N), and Receiver Box terminals (NL, A, B, O/T, O/T).

Combi-Boiler: Connects the Receiver Box to a combi-boiler. Similar terminal connections as basic boiler.

2-Port Zone Valve: Connects the Receiver Box to a 2-port zone valve system. Includes connections for 230V power (L, N), and Receiver Box terminals (NL, A, B, O/T, O/T), with a connection to the zone valve.

Troubleshooting

Troubleshooting – T4 and T4M only

Problem Display Possible Cause Remedy
Thermostat display is blank Batteries exhausted, installed incorrectly, or tab hasn't been removed. Unclip thermostat from wall and check battery installation; replace batteries if necessary.
Display shows ⚠️ (only for T4) Battery power critically low. Unclip thermostat from wall and replace batteries immediately.
Display shows ⚠️ Faulty temperature sensor. Replace thermostat or check wiring to remote temperature sensor if fitted.
Thermostat shows heat demand ? but boiler doesn't respond a. Boiler water already at temperature.
b. Faulty wiring connection.
a. Normal behaviour - wait for water temperature to drop.
b. Check wiring at thermostat and boiler terminals.

Troubleshooting – T4R

Problem Display Possible Cause Remedy
Thermostat display is blank Batteries exhausted, installed incorrectly, or tab hasn't been removed. Pull thermostat from wall bracket or table stand and check battery installation; replace batteries if necessary.
Display shows ⚠️ Battery power critically low. Pull thermostat from wall bracket or table stand and check battery installation; replace batteries if necessary.
Display shows ⚠️ Faulty temperature sensor. Replace thermostat or check wiring to remote temperature sensor if fitted.
Thermostat shows heat demand ? but boiler doesn't respond a. Boiler water already at temperature.
b. Faulty wiring connection.
a. Normal behaviour - wait for water temperature to drop.
b. Check wiring at thermostat and boiler terminals.
Thermostat displays shows ⚠️ and Receiver Box ? LED is flashing RED Wireless communication with Receiver Box is lost. Move thermostat to a location where wireless communication is reliable.
Thermostat displays shows ⚠️ and Receiver Box ? LED is flashing OFF Thermostat and Receiver Box not bound. Move thermostat to a location where wireless communication is reliable.
Receiver Box LED is flashing ORANGE Receiver Box is in bind mode. Wait for bind mode to time out (3 min) or bind a Thermostat.

Ordering Specification

Description Model EAN code Literature
T4 wired thermostat T4H110A1021 5025121381215 All packaging contains 6 languages: English, Dutch, French, German, Italian and Spanish.
T4 wired thermostat for OpenTherm boilers T4H310A3032 5025121381208
T4 wireless thermostat Y4H910RF4003 5025121381079

PDF preview unavailable. Download the PDF instead.

Lyric Honeywell T4 T4M T4R Specification sheet Microsoft PowerPoint 2013

Related Documents

Preview Honeywell Thermostat Compatibility and Support Worksheet for Total Connect 2.0
Detailed compatibility and support information for Honeywell thermostats, including Vista, LynxTouch, and Lyric panels, when used with Total Connect 2.0. Covers ZWSTAT, TCC/REDLINK, and Lyric Round device support.
Preview Honeywell Lyric Thermostat Professional Install Guide
A comprehensive guide for the professional installation of the Honeywell Lyric Thermostat, covering system compatibility, wiring, setup procedures, advanced configurations, troubleshooting, and basic operations.
Preview Honeywell Lyric T6 Pro Wi-Fi Programmable Thermostat Professional Install Guide
A comprehensive guide for the professional installation of the Honeywell Lyric T6 Pro Wi-Fi Programmable Thermostat, covering wiring, setup, and troubleshooting.
Preview Honeywell Lyric Round Wi-Fi Thermostat Installation Guide
Learn how to install and set up your Honeywell Lyric Round Wi-Fi Thermostat. This guide covers compatibility, tools needed, and step-by-step installation instructions.
Preview Honeywell Lyric Round Wi-Fi Thermostat: Getting Started Guide
Learn how to set up and use your Honeywell Lyric Round Wi-Fi Thermostat and the accompanying Lyric app for smart home climate control. Discover features like location-based temperature control, custom shortcuts, and smart alerts.
Preview Honeywell Lyric T6 Pro Wi-Fi Programmable Thermostat: Getting Started and User Guide
This guide provides essential information for setting up and using the Honeywell Lyric T6 Pro Wi-Fi Programmable Thermostat, including connection steps, operational features, and support contacts.
Preview Honeywell Lyric T5 Wi-Fi Thermostat: Quick Install Guide
Install and set up your Honeywell Lyric T5 Wi-Fi Thermostat with this easy-to-follow guide. Learn about smart scheduling, alerts, and compatibility for efficient home climate control.
Preview Honeywell Lyric T5 Wi-Fi Thermostat: Quick Install Guide
Get started with your Honeywell Lyric T5 Wi-Fi Thermostat. This guide provides clear instructions for installation, wiring, Wi-Fi setup, and app integration for smart home climate control.