Quick Installation Guide

X1/X3-EVC Series 7.2 kW-22 kW (Commercial Edition)

This document provides essential steps for installing your Solax EV Charger.

Packing List

  • EV-Charger × 1
  • Expansion bolts × 3/5 (3 for Socket Type, 5 for Plug Type)
  • Self tapping screws × 3/5 (3 for Socket Type, 5 for Plug Type)
  • Gasket × 3/5 (3 for Socket Type, 5 for Plug Type)
  • European terminal × 3/5 (3 for single-phase; 5 for three-phase)
  • Private RFID card × 2
  • Cable hook × 1 (only for Plug Type)
  • Documents

Installation Steps

STEP 1: Prepare the Charger

Remove the screw from the EV-Charger using a cross screwdriver ?. Carefully detach the back bracket.

STEP 2: Mount the Bracket

Fix the back bracket and the cable hook (for Plug Type) to the wall. This involves inserting expansion bolts, marking hole positions, drilling holes (∅ 8mm, depth at least 45mm ?️), aligning the bracket and hook, and screwing them in with self-tapping screws (torque: 1.5~2 N·m ?️).

STEP 3: Estimate Cable Length

Temporarily hang the EV-Charger on the wall. Estimate the required length for the input cable (three-core for single-phase, five-core for three-phase, outer diameter: 12.5-18 mm) and communication cable. Remove the EV-Charger after estimation.

STEP 4: Access Internal Components

Unscrew the EV-Charger's rear cover using a cross screwdriver ? and remove it. Then, undo the fastening heads and remove the waterproof materials.

STEP 5: Remove Communication Board Base Plate

Unscrew the countersunk screw of the communication board's base plate using a cross screwdriver ?. Pull the base plate out.

STEP 6: Insert Communication Cable

Insert the communication cable (from meter, CT, or other devices) through the waterproof connector. Refer to the "CT/Meter Connection" section for CT or meter installation details.

STEP 7: Prepare Input Cable Wires

Strip the outer sheath of the input cable (approx. 75-80 mm). Strip approximately 12 mm of insulation from the end of each colored wire. Crimp European terminals onto the stripped wire ends using a wire crimper. Ensure wires reach terminal blocks with slight excess length.

Wire stripping details: Outer Sheath (75-80 mm), Strip length (12 mm). Ensure < 4 mm of bare wire is exposed after terminal crimping.

Wire definitions:

PINDefinition
1L1_CT+
2L1_CT-
3L2_CT+ (null for single-phase)
4A1
5B1
6L2_CT- (null for single-phase)
7L3_CT+ (null for single-phase)
8L3_CT- (null for single-phase)

STEP 8: Insert Input Cable

Insert the prepared input cable through the waterproof connector.

STEP 9: Connect Wires to Terminals

Insert the wires into the appropriate terminal block holes. Secure the terminals using a straight screwdriver ? (torque: 1.5~1.8 N·m ?️).

STEP 10: Reinstall Communication Board

Press the spring upward and push the communication board's base plate back in. Screw the countersunk screw to secure it (torque: 0.8~1.5 N·m ?️).

STEP 11: Reattach Rear Cover

Position the rear cover correctly over the cables. Screw the self-tapping screws using a cross screwdriver ?. Tighten the waterproof fastening heads (torque: 2~2.5 N·m ?️).

STEP 12: Final Mounting

Carefully hang the EV-Charger onto the wall bracket. Secure it with self-tapping screws using a cross screwdriver ? (torque: 2~2.5 N·m ?️). For Plug Type, connect the charging connector to the EV-Charger and hang the connecting cable on the hook.

CT/Meter & WiFi Connection

CT/Meter Connection

For "Private Charger" Scenarios: Connect the AC distribution box, CT/Electricity meter, and EV-Charger. The meter should be bidirectional.

For "Commercial Charger (OCPP)" Scenarios: Connect the AC distribution box, Electricity meter, Electrical grid, and EV-Charger. The meter should be bidirectional and connect via OCPP1.6.

Note: If a CT is installed, the arrow on the CT must point towards the public grid ➡️. For meter installation, consult the respective quick installation guide.

WiFi Connection

Step 1: Download App: Scan the provided QR code ? or search for "SolaXCloud" in your browser to download the Monitoring App for iOS or Android.

Step 2: Create Account: Open the Monitoring App and create a new account.

Step 3: Configure WiFi: Log in to the app, navigate to the "Account" page, tap "Wifi Connection" ?, and follow the on-screen instructions to complete the setup.

Manual WiFi Configuration: If manual configuration is required, the IP address is http://192.168.10.10/.

Models: X3-EVC Series, X3-EVC Series Commercial Edition, Commercial Edition, Edition

File Info : application/pdf, 2 Pages, 8.60MB

PDF preview unavailable. Download the PDF instead.

(COMMERCIAL)(EN) Guide d'installtion rapide Solax Borne de recharge X1-X3

References

PDFium PDFium

Related Documents

Preview SolaX EV-Charger 7.2 kW-22 kW Quick Installation Guide
A step-by-step guide for the installation of the SolaX EV-Charger, covering models from 7.2 kW to 22 kW. Includes packing list and connection instructions for CT and WiFi.
Preview SolaX X1/X3-EVC Series EV Charger Quick Installation Guide
This guide provides step-by-step instructions for the quick installation of the SolaX X1/X3-EVC Series EV Charger (Home Edition), including packing list details, mounting procedures, and CT/WiFi connection setup.
Preview SolaX X3-IES Series: Installation Manual for Residential Energy Storage Systems
Comprehensive installation manual for the SolaX X3-IES series of residential energy storage systems, covering models from 4 kW to 15 kW. This guide provides essential safety information, installation procedures, and technical details for qualified installers.
Preview SolaX X3-PRO G2 Series 8 kW-30 kW Quick Installation Guide
A concise guide for installing the SolaX X3-PRO G2 Series 8 kW-30 kW solar inverter, covering packing, mounting, electrical connections (PV, AC, Earth), and communication setup.
Preview Solax X1-IES Series Installation Manual
This installation manual provides comprehensive instructions for the Solax X1-IES series of residential single-phase photovoltaic storage hybrid inverter systems, including models from 2.5 kW to 8.0 kW. It details the components, installation procedures, electrical connections, and general settings for safe and efficient setup.
Preview Solax X3-PRO G2 Series Quick Installation Guide
A concise guide for the quick installation of the Solax X3-PRO G2 Series inverters, covering packing list, inverter installation, PV connection, AC connection, earth connection, and optional WiFi and USB connections.
Preview SolaX X1-Lite-LV Installation Manual
This installation manual provides detailed instructions for the SolaX X1-Lite-LV inverter, covering safety precautions, installation procedures, and important notices for qualified personnel.
Preview SOLAX X3-Hybrid G4 Pika-asennusopas: Asennusohjeet
Kattava pika-asennusopas SOLAX X3-Hybrid G4 -sarjan aurinkoinverttereille (5.0 kW – 15.0 kW). Opas sisältää pakkausluettelon, työkalujen valmistelun, asennusvaiheet, liitäntäohjeet (PV, akku, verkko, EPS), tietoliikenneyhteydet, maadoituksen, valvontatoiminnot, käynnistyksen ja laiteohjelmiston päivityksen.