EPH Controls RDTP Recessed Room Thermostat: Installation and Operation Guide

RDTP Recessed Room Thermostat

Installation and Operation Guide

A white, square digital thermostat (RDTP model) is shown. The LCD screen displays "MON", "ROOM TEMP 21.0°", the date "15.02.08:30", and "AUTO". Below the screen are buttons labeled with icons and text: Menu (☰), Time (◷), +1h (+1h), Down (⌄), Up (⌃), OK (OK). The EPH CONTROLS logo is visible.

Introduction

This guide provides comprehensive instructions for the installation and operation of the EPH Controls RDTP Recessed Room Thermostat.

Installation Instructions

Factory Default Settings ⚙️

  • High and Low Temp. limitation: Off
  • Keypad lock: Off
  • Operating mode: Normal
  • Temperature indicator: °C
  • Frost protection: On (5°C)
  • HYS On: 0.4°C
  • HYS OFF: 0.0°C

Specifications

  • Switch output: SPDT Volt Free
  • Power supply / Input: 230Vac
  • Power consumption: Operating <1W, Standby 0.1 mW
  • Temperature range: 5 ... 35°C
  • Ambient temperature: 0 ... 45°C
  • Ambient admissible humidity: 5 - 95%RH
  • Contact rating: 10(3)A 230Vac
  • Dimensions: 95 x 95 x 40mm
  • Internal Temperature sensor: NTC 100K
  • External Temperature sensor: NTC 10K
  • Program memory backup: 3 months
  • Battery: LIR2032
  • Backlight: White
  • IP rating: IP20
  • Pollution degree: 2
  • Hysteresis (Switching differential): Adjustable from 0 to 1°C (0.1°C increments)
  • Automatic action: 1C

LCD Display ⚙️

The LCD display shows various information:

  • [1] Displays current day of the week.
  • [2] Displays when setting target temperature.
  • [3] Displays current room temperature.
  • [4] Displays when setting HIGH and LOW temperature limit.
  • [5] Displays when keypad is locked.
  • [6] Displays when the thermostat is calling for heat (? symbol).
  • [7] Displays current time and date.
  • [8] Displays when setting holiday mode.
  • [9] Displays when thermostat is in boost mode.
  • [10] Displays current operating mode.
  • [11] Displays current / target temperature.
  • [12] Displays current time program.
Diagram shows thermostat LCD with labels: MON TUE WED THU FRI SAT SUN, SET ROOM TEMP HI LO LIM, numbered segments 1-6, and status indicators AUTO, OFF, MAN, BOOST, HOLIDAY, TO FROM.

Buttons

The thermostat has the following buttons:

  • Menu button: ☰
  • Time button: ◷
  • +1h button: [+1h]
  • Down button: ⌄
  • Up button: ⌃
  • OK button: [OK]
Image shows the thermostat with labels pointing to each button: Menu button (☰), Time Button (◷), +1h Button (+1h), Down Button (⌄), Up Button (⌃), OK Button ([OK]).

Wiring

Wiring terminal block diagram shows terminals labeled: 5 (Temp Sensor), 4 (Temp Sensor), 3 (COM), 2 (ON), 1 (OFF), N (Neutral), L (Live). A fuse symbol is shown above terminal 5.

Terminal Connections

  • L: Live In
  • N: Neutral In
  • Terminal 1: OFF - N/C Normally closed connection
  • Terminal 2: ON - N/O Normally open connection
  • Terminal 3: COM - Common connection
  • Terminal 4 & 5: *External Temperature Sensor / Probe (*Available as an accessory if required)

Notes:

  1. If mains output is required, terminals L and 3 must be electrically linked.
  2. If an external NTC 10K sensor is connected, the thermostat will automatically detect and read the temperature from the probe's location.

Mounting & Installation

Caution!

  • Installation and connection should only be carried out by a qualified person.
  • Only qualified electricians or authorised service staff are permitted to open the thermostat.
  • If the thermostat is used in a way not specified by the manufacturer, its safety may be impaired.
  • Prior to setting the thermostat, it is necessary to complete all required settings described in this section.
  • Before commencing installation, the thermostat must be first disconnected from the mains.

This thermostat can be mounted to a recessed conduit box.

Diagrams illustrate installation steps: 1. Shows thermostat dimensions (95x95x40.2mm) and certifications (UK CA, CE, IP20, EN60730, EN60529) with temperature ranges (°C/°F) and humidity. 2. Shows recommended mounting locations (wall, avoiding direct heat/sunlight) and incorrect locations (near vents, direct sun). 3. Illustrates separating the front housing from the rear wiring box using a clip. 4. Shows wiring connections to the rear box. 5. Shows mounting the rear box to a recessed back box. 6. Shows attaching the front housing to the rear box.

Installation Steps:

  1. Remove the thermostat from its packaging.
  2. Choose a mounting location so that the thermostat can measure the room temperature as accurately as possible.
    • Mount the thermostat 1.5 metres above the floor level.
    • Prevent direct exposure to sunlight or other heating / cooling sources.
  3. Use the fastening clip on the base of the thermostat to release the front housing from the rear wiring box as per diagram on page 12.
  4. Wire the thermostat according to the wiring diagram on page 9.
  5. Screw the rear wiring box to the recessed back box.
  6. Attach the front housing to the rear wiring box until it clips securely into place.

Operating Instructions

Adjusting the Target Temperature

  • Press ⌃ to increase the target temperature from 5-35°C.
  • Press [OK] or wait 5 seconds. The target temperature is now saved.
  • Press ⌄ to decrease the target temperature from 5-35°C.
  • Press [OK] or wait 5 seconds. The target temperature is now saved.

Locking the Keypad ?

  • To lock the thermostat, press and hold ⌄ and ⌃ for 10 seconds. A ? symbol will appear on the screen. The buttons are now disabled.
  • To unlock the thermostat, press and hold ⌄ and ⌃ for 10 seconds. The ? symbol will disappear from the screen. The buttons are now enabled.

Backlight ⚙️

There are three settings for selection:

  • 'AUTO': The backlight is on for 10 seconds when any button is pressed.
  • 'On': The backlight is permanently on.
  • 'OFF': The backlight is permanently off.

To adjust the backlight setting, press and hold [OK] for 10 seconds. 'AUTO' appears on the screen.

Use ⌄ and ⌃ to change the mode between AUTO, ON and OFF.

Press [OK] to confirm selection and to return to normal operation.

Mode Selection ⚙️

There are three modes available for selection:

  • OFF: The thermostat is permanently off.
  • MAN (or manual): The thermostat is permanently on.
  • AUTO: The thermostat will operate according to the times and temperatures that have been pre-programmed.

Press ☰ to change between 'AUTO', 'OFF' & 'MAN'. The current mode will be underlined on the screen.

Press ☰ again to scroll through the three modes.

Press [OK] or wait 5 seconds to confirm.

When in Manual mode, the thermostat displays the current room temperature and the word 'MAN'.

When in OFF mode, the thermostat displays the current room temperature and the word 'OFF'.

When in AUTO mode, the thermostat displays the current room temperature, the number of the current program, and the word 'AUTO'.

Setting the Date, Time and Programming Mode

  • Press ◷ once, the year will begin flashing.
  • Press ⌄ and ⌃ to adjust the year. Press [OK].
  • Repeat this for the month, day, hour, and minute. Press [OK].
  • Press ⌄ and ⌃ to adjust from 5/2d to 7d or 24h mode. Press [OK].
  • Press ⌄ and ⌃ to turn DST (Day Light Saving time) On or Off.
  • Wait 20 sec or press ☰, the thermostat will return to normal operation.

Holiday Mode

Holiday mode will switch the thermostat off but will have frost protection enabled for the duration of the holiday period.

  • Press and hold ◷ for 5 seconds. 'HOLIDAY FROM' will appear on the screen.
  • Press ⌄, ⌃, and [OK] to set the time for holiday mode to begin. 'HOLIDAY TO' will appear on the screen.
  • Press ⌄, ⌃, and [OK] to set the time for holiday mode to end.
  • The thermostat will switch off for the holiday period.
  • Press [OK] to cancel the holiday function.

How your Programmable Thermostat works

When the thermostat is in AUTO mode, it will operate according to the times and temperatures that have been programmed. The user can select from 6 different programs per day, each with a time and a temperature.

There is no OFF time; only a higher and a lower target temperature. If the user wants the thermostat to be OFF at a certain time, set the temperature for this time to be low. The thermostat will turn ON if the room temperature is lower than the target temperature for the current period.

Example: If P1 is set to be 21°C at 6am, and if P2 is set to be 10°C at 8am, the thermostat will look for the temperature to be 21°C between 6am and 8am.

Factory Program Setting ⚙️

5/2 Day
P1 P2 P3 P4 P5 P6
Mon-Fri 06:30
21°C
08:00
10°C
12:00
10°C
14:00
10°C
17:30
21°C
22:00
10°C
Sat-Sun 08:00
21°C
10:00
10°C
12:00
10°C
14:00
10°C
17:30
21°C
23:00
10°C
7 Day
P1 P2 P3 P4 P5 P6
Mon-Fri 06:30
21°C
08:00
10°C
12:00
10°C
14:00
10°C
17:30
21°C
22:00
10°C
Sat-Sun 08:00
21°C
10:00
10°C
12:00
10°C
14:00
10°C
17:30
21°C
23:00
10°C
24 Hour
P1 P2 P3 P4 P5 P6
Everyday 06:30
21°C
08:00
10°C
12:00
10°C
14:00
10°C
17:30
21°C
22:00
10°C

Programming Modes

The RDTP Room Thermostat has the following programming modes available:

  • 5/2 Day mode: Programing Monday to Friday as one block and Saturday and Sunday as a 2nd block. Each block can have 6 different times and target temperatures.
  • 7 Day mode: Programming all 7 days individually with different times and target temperatures.
  • 24 Hour mode: Programming all 7 days as one block with the same times and target temperatures.

If 7 D mode is selected, you can program each day of the week with 6 individual times and temperatures.

If 24H mode is selected, you can only program each day of the week with the same 6 times and temperatures.

Adjust the Program Setting in 5/2 Day Mode

  • Press ◷ twice. Programming for Monday to Friday is now selected.
  • Press ⌄ and ⌃ to adjust the P1 time. Press [OK].
  • Press ⌄ and ⌃ to adjust the P1 temperature. Press [OK].
  • Repeat this process to adjust P2 to P6 times & temperatures. Press [OK].
  • Programming for Saturday to Sunday is now selected.
  • Press ⌄ and ⌃ to adjust the P1 time. Press [OK].
  • Press ⌄ and ⌃ to adjust the P1 temperature. Press [OK].
  • Repeat this process to adjust P2 to P6 times & temperatures. Press [OK].
  • Press ☰ to return to automatic mode.
  • While in programming mode, pressing ◷ will jump to the next day (block of days).

Temporary Override

When in AUTO mode, press ⌄ or ⌃ to adjust the target temperature. Press [OK] or wait 5 seconds, the thermostat will operate to this new target temperature until the next switching time.

Permanent Override

  • Press ☰ to select 'MAN' or manual mode (Permanent Override).
  • Press [OK].
  • Press ⌄ or ⌃ to adjust the target temperature.
  • Press [OK] or wait 5 seconds, the thermostat will operate to this target temperature.
  • To cancel permanent override, press ☰ until the 'AUTO' or 'OFF' mode are selected.

Boost Function

The thermostat can be boosted to a specific temperature for 1, 2 or 3 hours while the thermostat is operating in all modes except for holiday mode.

  • Press [+1h] 1, 2 or 3 times, the end time of the boost program will appear flashing on the screen.
  • If you press [OK], the temperature will now flash. You can adjust the target temperature by pressing the ⌄ or ⌃.
  • Press [OK] or wait for 5 seconds for the boost to activate.
  • 'BOOST TO' will now be displayed on the screen with the end time for the boost program.
  • Press [+1h] again to deactivate the boost, the thermostat will revert to its previous operating mode.

Contact Information

EPH Controls IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
Cork, T12 W665

EPH Controls UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/contact-us
+44 1933 322 072
Harrow, HA1 1BD

© 2025 EPH Controls Ltd.

Models: RDTP, RDTP Recessed Room Thermostat, RDTP, Recessed Room Thermostat, Room Thermostat, Thermostat

File Info : application/pdf, 36 Pages, 465.06KB

PDF preview unavailable. Download the PDF instead.

RDTP Datasheet-1

References

Related Documents

Preview EPH Controls CDT2 Room Thermostat: Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CDT2 mains operated non-programmable room thermostat, covering features, settings, and troubleshooting.
Preview EPH Controls CDTP2 Room Thermostat Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CDTP2 Room Thermostat, covering features like programming modes, temperature settings, and advanced functions.
Preview CDT2 Room Thermostat with Delay Start - Operating Instructions
Comprehensive operating instructions for the EPH Controls CDT2 Room Thermostat with Delay Start, covering installation, wiring, modes of operation, and advanced settings like TPI control.
Preview EPH CP4V2 Programmable RF Thermostat & Receiver: Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4V2 Programmable RF Thermostat and RF1B Wireless Receiver, covering setup, features, and system integration for efficient home heating control.
Preview EPH Controls CP4B Battery Powered Programmable Thermostat: Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4B battery-powered programmable thermostat, covering setup, programming, and advanced features.
Preview EPH Controls CP4D Programmable RF Thermostat & Receiver Installation and Operation Guide
Comprehensive guide for installing and operating the EPH Controls CP4D programmable RF thermostat and receiver system, detailing setup, features, and system integration.
Preview CP4D Programmable RF Thermostat & Receiver Installation and Operation Guide
This guide provides comprehensive installation and operation instructions for the EPH Controls CP4D Programmable RF Thermostat & Receiver. Learn about setup, features, and troubleshooting for optimal home climate control.
Preview RFRA RF Room Thermostat Installation Instructions | EPH Controls
Comprehensive installation guide for the EPH Controls RFRA RF Room Thermostat, covering mounting options, safety precautions, and step-by-step setup for optimal performance.