Rheem-Ruud Tankless Heavy-Duty Gas Water Heaters

Available in 7.4 GPM Indoor and Outdoor Models

Warranty Information

10-Year Limited Warranty on Heat Exchanger*

3-Year Limited Warranty on Parts*

*See Residential Warranty Information Brochure for complete warranty information. If the water heater is installed anywhere other than a single family dwelling, such as a commercial application, or in any system in which the water is recirculated, the applicable warranty periods will be limited to three (3) years for heat exchanger; one (1) year for parts.

Key Features

Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate: natural gas 91¢/therm; LP $1.23/gallon.

Model Specifications

Model NumberGas Input BTU/HR.TypeTemp. Rise Range (°F)Water Flow Rate (GPM)ConnectionsRoughing In Dimensions (Inches)Ship. Weight (Lbs.)Energy FactorEst. Ann. Operating Cost
Rise Max.@ 77°F@ 45°F Rise Max.WaterGasHeightWidthDepthVent
GT-199PVN-1+19,000 - 199,900Indoor100° to 180° F4.37.43/43/425-3/814-7/811-1/8455.82$167 Nat / $246 LP
GT-199XN-1+19,000 - 199,900Outdoor100° to 180° F4.37.43/43/425-3/814-7/811-1/8N/A55.82$167 Nat / $246 LP
GT-199DVN-1+19,000 - 199,900Indoor Direct Vent 2-PIPE100° to 180° F4.37.43/43/425-3/814-7/811-1/84 by 455.82$167 Nat / $246 LP

+ Available in Natural Gas and Propane (LP). For Propane, replace the 'N' with a 'P' when ordering.

* Factory set maximum temperature is 120°F, capable of temperatures up to 180°F. See Use and Care Manual for setting.

• For installations above 3,280 feet, a high-altitude chip is required. Refer to Rheem price list or consult factory for details.

• Consult factory for information on sizing the application.

Installation Vent Kits: Available separately. Part number RTG20007 Installation Vent Kit includes 4" diameter components for a horizontal through-the-wall termination. Vent Kits for Direct Vent models are listed on page 2.

Unit Performance and Requirements

These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures. They meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code, and all state energy efficiency performance criteria for energy-consuming appliances.

Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.

Maximum Hot Water Flow Rate and Temperature Rise

Temp. Rise (°F)35455060707790100110120130140
Water Flow (GPM)8.57.46.65.54.74.34.13.73.32.82.62.4

Minimum flow rate required to initiate heating cycle: 0.66 GPM. Above estimates are for sizing purposes only.

Clearance to Combustibles (inches)

Model NumberFrontTop & SideRearBottom
GT-199PV1/20120
GT-199X1/20120

Dimensions (Inches)

Model NumberGas Input BTU/HRABCDepthVent*Connections (Water/Gas)Approximate Shipping Weight
GT-199PV19,000-199,90025-3/814-7/828-3/411-1/843/4 / 3/455 lbs.
GT-199X19,000-199,90025-3/814-7/82211-1/8N/A3/4 / 3/455 lbs.
GT-199DV19,000-199,90025-3/814-7/828-3/411-1/84 by 4 (2-PIPE)3/4 / 3/455 lbs.

* Category III stainless steel (UL1738 certified) vent is required.

• Specify natural or LP gas when ordering.

• Electrical rating: 120V, 60HZ, less than 2 amps. Indoor model supplied with 120 volt power cord.

Rheem-Ruud GT-199 Manifold Installations

Flow Rate (GPM) by Number of Units and Temperature Rise

Temp. Rise (°F)1 UNIT2 UNITS5 UNITS10 UNITS15 UNITS20 UNITS
1402.44.812.024.036.048.0
1302.65.213.026.039.052.0
1202.85.614.028.042.056.0
1103.06.015.030.045.060.0
1003.36.616.533.049.566.0
903.77.418.537.555.574.0
804.28.421.042.063.084.0
704.89.624.048.072.096.0
605.611.228.056.084.0112.0
506.713.433.567.0100.5134.0
457.414.837.074.0111.0148.0
358.517.042.585.0127.5170.0

Extensive Manifold Capacity

Up to 20 of the Heavy Duty Tankless units can be linked in a manifold configuration to meet the hot water needs of larger applications.

Diagram Description: A visual representation shows three tankless units (Unit 1, Unit 2, Unit 3) connected in series. A Manifold Control (MIC-180) is depicted managing the units, alongside a Remote Thermostat Control. The text indicates that up to 20 units can be linked in this manifold configuration for increased hot water demand.

Installation and Venting

Indoor and Direct Vent Models Vent Horizontally or Vertically. These water heaters have a built-in electric blower to force exhaust gas to the outside. Category III stainless steel (UL1738 certified) vent is required to avoid damage from possible condensation. Maximum vent length for GT-199 models is 47 feet 6 inches including one 90° elbow. Maximum vent length for GT-199DV models is 47 feet 6 inches including two 90° elbows. Type "B" vents are not permitted.

Diagram Description: Venting side wall from side.

Diagram Description: Venting side wall from back.

Diagram Description: GT-199DV standard termination venting side wall.

Diagram Description: GT-199DV sweet termination venting side wall (Coming Soon!).

Accessories for Multi-Unit Manifold Installations

Part No.Description# of Water Heaters (Accessories)
23 TO 67 TO 20
RTG20040EZ-Link™ Cable1N/AN/A
MIC-180Main Communication PCB w/ Manifold Control BoxN/A11
MICS-180Extended Communications PCBN/AN/A1
MIC-K-16Communications Cable (16 ft.)N/A3 to 67 to 20
MIC-K-32Communications Cable (32 ft.)N/A3 to 67 to 20
MIC-K-65Communications Cable (65 ft.)N/A3 to 67 to 20

Required Direct Vent Termination Kits

Kits include the termination components only; vent pipe from the heater to the termination is not included. Horizontal and Vertical kits for Heat Fab and Protech are available.

ModelTerminationHeat FabProtech
GT-199DVHorizontalRTG-20032HHTRTG20034HPT
GT-199DVVerticalRTG20033VHTRTG20035VPT
GT-199DVSweetRTG20058N/A
For 5"-9" Wall ThicknessRTG20059
For 9"-13" Wall ThicknessRTG20060

In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.

Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com

PRINTED IN U.S.A 12/06 WP FORM NO. 101-24 Rev. 2

PDF preview unavailable. Download the PDF instead.

kfxioa079tv4 Acrobat Distiller 4.0 for Macintosh

Related Documents

Preview Rheem-Ruud Point-Of-Use Electric Commercial Water Heaters | Specifications & Features
Explore Rheem-Ruud's line of point-of-use electric commercial water heaters (EGSP series). Discover features, construction, specifications, and certifications for efficient hot water solutions.
Preview Rheem RUUD Induced Draft Gas Commercial Water Heaters | Specifications & Features
Comprehensive overview of Rheem RUUD Induced Draft Gas Commercial Water Heaters, including model specifications, recovery capacities, dimensions, construction features, and certifications. Ideal for commercial applications requiring high hot water volumes.
Preview Rheem-Ruud Commercial Electric Tank-Type Water Heaters 9-36 KW | Specifications and Features
Detailed specifications and features for Rheem-Ruud's surface-mounted commercial electric tank-type water heaters (9-36 KW). Covers construction, energy efficiency, model applications, electrical data, recovery rates, dimensions, and warranty.
Preview Rheem-Ruud 6kW - 54kW Electric Booster Commercial Water Heaters
Comprehensive details on Rheem-Ruud Electric Booster Commercial Water Heaters, covering models from 6kW to 54kW. This document outlines key features like the System Sentinel diagnostic panel, long-life heating elements, and high-temperature porcelain enamel tanks. It includes detailed electrical characteristics, recovery capacities, dimensions, certifications (UL, NSF5), and warranty information for commercial applications.
Preview VentMaster Commercial Water Heaters: Power Direct Vent Gas Models by Rheem-Ruud
Explore the VentMaster series of power direct vent gas commercial water heaters by Rheem-Ruud. Featuring 100-gallon tank models with capacities from 150,000 to 250,000 BTU/Hr, these units offer advanced features, high efficiency, and robust construction for demanding commercial applications.
Preview Rheem-Ruud Commercial Water Heater Certified Installation Drawings
Comprehensive guide featuring certified installation drawings for Rheem-Ruud commercial water heater systems, including duplex, triplex, quadplex, and single heater dual temperature configurations. Essential technical information for installers.
Preview Rheem-Ruud Commercial Electric Booster Water Heaters 6 kW - 18 kW
Comprehensive guide to Rheem-Ruud commercial electric booster water heaters, covering models from 6 kW to 18 kW. Details features like System Sentinel diagnostics, Rheemglas lining, high-temperature sanitizing rinse water capabilities, construction specifications, electrical data, recovery capacities, and warranty information.
Preview Rheem-Ruud Commercial Electric Tank-Type Water Heaters: 6 kW to 54 kW
Comprehensive technical specifications, construction features, model details, electrical characteristics, and recovery data for Rheem-Ruud commercial electric tank-type water heaters (6 kW to 54 kW).