Rheem-Ruud Tankless Heavy-Duty Gas Water Heaters
Available in 7.4 GPM Indoor and Outdoor Models
Warranty Information
10-Year Limited Warranty on Heat Exchanger*
3-Year Limited Warranty on Parts*
*See Residential Warranty Information Brochure for complete warranty information. If the water heater is installed anywhere other than a single family dwelling, such as a commercial application, or in any system in which the water is recirculated, the applicable warranty periods will be limited to three (3) years for heat exchanger; one (1) year for parts.
Key Features
- New! UMC-117 remote control included, adjustable from 120°F up to a 180°F maximum (additional remote control thermostats available separately).
- New! EZ-Link™ cable connects two tankless units to operate as one, available for high-demand applications.
- Exclusive! Guardian SBT™ sensing burner technology.
- Exclusive! Guardian OFW™ overheat film wrap.
- Exclusive! Two high-altitude options: up to 6,560 ft. or 9,840 ft. elevations (altitude chip required, sold separately).
- Exclusive! All Rheem tankless models are third-party certified by GAMA.
- Exclusive! All Rheem tankless models qualify for up to a $300 federal energy tax credit (refer to your tax advisor for details).
- Exclusive! All Rheem models can be linked in up to 20-unit manifold installations using the optional MIC-180 and MICS-180 manifold control assembly.
- GT-199 units are specifically designed for heavy-duty residential and commercial applications.
- Provides continuous hot water.
- Energy saving design.
- Compact, space-saving design.
- Intelligent electronic controls designed to increase energy efficiency and safety.
- Self-diagnostic program.
- Digital display shows temperature setting and maintenance codes.
- Built-in electric blower.
- Indoor units use Category III stainless steel vents and vent horizontally or vertically.
- Indoor models supplied with a 120-volt power cord.
- Environmentally friendly Low NOx burner meets SCAQMD rule 1146 requirements.
- Installation vent kits available (sold separately).
- Indoor and outdoor models feature freeze protection down to -30°F.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate: natural gas 91¢/therm; LP $1.23/gallon.
Model Specifications
Model Number | Gas Input BTU/HR. | Type | Temp. Rise Range (°F) | Water Flow Rate (GPM) | Connections | Roughing In Dimensions (Inches) | Ship. Weight (Lbs.) | Energy Factor | Est. Ann. Operating Cost | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rise Max. | @ 77°F | @ 45°F Rise Max. | Water | Gas | Height | Width | Depth | Vent | ||||||
GT-199PVN-1+ | 19,000 - 199,900 | Indoor | 100° to 180° F | 4.3 | 7.4 | 3/4 | 3/4 | 25-3/8 | 14-7/8 | 11-1/8 | 4 | 55 | .82 | $167 Nat / $246 LP |
GT-199XN-1+ | 19,000 - 199,900 | Outdoor | 100° to 180° F | 4.3 | 7.4 | 3/4 | 3/4 | 25-3/8 | 14-7/8 | 11-1/8 | N/A | 55 | .82 | $167 Nat / $246 LP |
GT-199DVN-1+ | 19,000 - 199,900 | Indoor Direct Vent 2-PIPE | 100° to 180° F | 4.3 | 7.4 | 3/4 | 3/4 | 25-3/8 | 14-7/8 | 11-1/8 | 4 by 4 | 55 | .82 | $167 Nat / $246 LP |
+ Available in Natural Gas and Propane (LP). For Propane, replace the 'N' with a 'P' when ordering.
* Factory set maximum temperature is 120°F, capable of temperatures up to 180°F. See Use and Care Manual for setting.
• For installations above 3,280 feet, a high-altitude chip is required. Refer to Rheem price list or consult factory for details.
• Consult factory for information on sizing the application.
Installation Vent Kits: Available separately. Part number RTG20007 Installation Vent Kit includes 4" diameter components for a horizontal through-the-wall termination. Vent Kits for Direct Vent models are listed on page 2.
Unit Performance and Requirements
These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures. They meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code, and all state energy efficiency performance criteria for energy-consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your supplier.
Maximum Hot Water Flow Rate and Temperature Rise
Temp. Rise (°F) | 35 | 45 | 50 | 60 | 70 | 77 | 90 | 100 | 110 | 120 | 130 | 140 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Water Flow (GPM) | 8.5 | 7.4 | 6.6 | 5.5 | 4.7 | 4.3 | 4.1 | 3.7 | 3.3 | 2.8 | 2.6 | 2.4 |
Minimum flow rate required to initiate heating cycle: 0.66 GPM. Above estimates are for sizing purposes only.
Clearance to Combustibles (inches)
Model Number | Front | Top & Side | Rear | Bottom |
---|---|---|---|---|
GT-199PV | 1/2 | 0 | 12 | 0 |
GT-199X | 1/2 | 0 | 12 | 0 |
Dimensions (Inches)
Model Number | Gas Input BTU/HR | A | B | C | Depth | Vent* | Connections (Water/Gas) | Approximate Shipping Weight |
---|---|---|---|---|---|---|---|---|
GT-199PV | 19,000-199,900 | 25-3/8 | 14-7/8 | 28-3/4 | 11-1/8 | 4 | 3/4 / 3/4 | 55 lbs. |
GT-199X | 19,000-199,900 | 25-3/8 | 14-7/8 | 22 | 11-1/8 | N/A | 3/4 / 3/4 | 55 lbs. |
GT-199DV | 19,000-199,900 | 25-3/8 | 14-7/8 | 28-3/4 | 11-1/8 | 4 by 4 (2-PIPE) | 3/4 / 3/4 | 55 lbs. |
* Category III stainless steel (UL1738 certified) vent is required.
• Specify natural or LP gas when ordering.
• Electrical rating: 120V, 60HZ, less than 2 amps. Indoor model supplied with 120 volt power cord.
Rheem-Ruud GT-199 Manifold Installations
Flow Rate (GPM) by Number of Units and Temperature Rise
Temp. Rise (°F) | 1 UNIT | 2 UNITS | 5 UNITS | 10 UNITS | 15 UNITS | 20 UNITS |
---|---|---|---|---|---|---|
140 | 2.4 | 4.8 | 12.0 | 24.0 | 36.0 | 48.0 |
130 | 2.6 | 5.2 | 13.0 | 26.0 | 39.0 | 52.0 |
120 | 2.8 | 5.6 | 14.0 | 28.0 | 42.0 | 56.0 |
110 | 3.0 | 6.0 | 15.0 | 30.0 | 45.0 | 60.0 |
100 | 3.3 | 6.6 | 16.5 | 33.0 | 49.5 | 66.0 |
90 | 3.7 | 7.4 | 18.5 | 37.5 | 55.5 | 74.0 |
80 | 4.2 | 8.4 | 21.0 | 42.0 | 63.0 | 84.0 |
70 | 4.8 | 9.6 | 24.0 | 48.0 | 72.0 | 96.0 |
60 | 5.6 | 11.2 | 28.0 | 56.0 | 84.0 | 112.0 |
50 | 6.7 | 13.4 | 33.5 | 67.0 | 100.5 | 134.0 |
45 | 7.4 | 14.8 | 37.0 | 74.0 | 111.0 | 148.0 |
35 | 8.5 | 17.0 | 42.5 | 85.0 | 127.5 | 170.0 |
Extensive Manifold Capacity
Up to 20 of the Heavy Duty Tankless units can be linked in a manifold configuration to meet the hot water needs of larger applications.
Diagram Description: A visual representation shows three tankless units (Unit 1, Unit 2, Unit 3) connected in series. A Manifold Control (MIC-180) is depicted managing the units, alongside a Remote Thermostat Control. The text indicates that up to 20 units can be linked in this manifold configuration for increased hot water demand.
Installation and Venting
Indoor and Direct Vent Models Vent Horizontally or Vertically. These water heaters have a built-in electric blower to force exhaust gas to the outside. Category III stainless steel (UL1738 certified) vent is required to avoid damage from possible condensation. Maximum vent length for GT-199 models is 47 feet 6 inches including one 90° elbow. Maximum vent length for GT-199DV models is 47 feet 6 inches including two 90° elbows. Type "B" vents are not permitted.
Diagram Description: Venting side wall from side.
Diagram Description: Venting side wall from back.
Diagram Description: GT-199DV standard termination venting side wall.
Diagram Description: GT-199DV sweet termination venting side wall (Coming Soon!).
Accessories for Multi-Unit Manifold Installations
Part No. | Description | # of Water Heaters (Accessories) | ||
---|---|---|---|---|
2 | 3 TO 6 | 7 TO 20 | ||
RTG20040 | EZ-Link™ Cable | 1 | N/A | N/A |
MIC-180 | Main Communication PCB w/ Manifold Control Box | N/A | 1 | 1 |
MICS-180 | Extended Communications PCB | N/A | N/A | 1 |
MIC-K-16 | Communications Cable (16 ft.) | N/A | 3 to 6 | 7 to 20 |
MIC-K-32 | Communications Cable (32 ft.) | N/A | 3 to 6 | 7 to 20 |
MIC-K-65 | Communications Cable (65 ft.) | N/A | 3 to 6 | 7 to 20 |
Required Direct Vent Termination Kits
Kits include the termination components only; vent pipe from the heater to the termination is not included. Horizontal and Vertical kits for Heat Fab and Protech are available.
Model | Termination | Heat Fab | Protech |
---|---|---|---|
GT-199DV | Horizontal | RTG-20032HHT | RTG20034HPT |
GT-199DV | Vertical | RTG20033VHT | RTG20035VPT |
GT-199DV | Sweet | RTG20058 | N/A |
For 5"-9" Wall Thickness | RTG20059 | ||
For 9"-13" Wall Thickness | RTG20060 |
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
PRINTED IN U.S.A 12/06 WP FORM NO. 101-24 Rev. 2