Anslut Bathroom Fan
Model: 012895
Safety Instructions
- Disconnect the product from the mains before connecting, maintenance, and/or repair.
- Installation, maintenance, and/or repairs should be carried out by an authorized electrician and in accordance with these instructions.
- The product is intended to be connected to 230 V 1-phase installations that comply with local regulations.
- The product must be connected via a permanently installed automatic fuse with a minimum contact gap of 3 mm on all terminals.
- Check before installation that the impeller and casing are undamaged.
- There must be no foreign objects in the casing that could damage the fan blades.
- The product must only be used for its intended purpose and in accordance with these instructions. Do not make any modifications to the product.
- The product is not intended to be used by persons (children or adults) with any form of functional disorders, or by persons who do not have sufficient experience or knowledge on how to use it, unless they have received instructions concerning the use of the product from someone who is responsible for their safety.
- Keep children under supervision to make sure they do not play with the product.
- Take the necessary precautions to prevent smoke, carbon monoxide and other flammable products from penetrating into the room through open flues or other fire safety devices.
- Make sure that the air supply is sufficient for correct combustion and adequate chimney draught, to prevent backward flow.
- The transported medium must not contain dust or other solid particles, sticky substances or fibres.
- Do not use the product in explosive environments, e.g. in the vicinity of flammable liquids, gas or dust, or in environments that contain toxic or harmful substances.
- Do not block the openings on the product to attempt to direct or adjust the air flow.
- The product is intended for permanent connection to the mains.
Symbols
- [Read Instructions] (Symbol: Open book icon)
- Safety Class II (Symbol: Square within a square icon)
- CE Approved (Symbol: CE logo)
- Recycle discarded product (Symbol: Recycling arrows icon)
Electrical Safety
New installations and extensions to existing systems should always be carried out by an authorized electrician. If you have the necessary experience and knowledge (otherwise contact an electrician), you can replace power switches and wall sockets, fit plugs, extension cords and light sockets. Incorrect installation can result in fatal injury and the risk of fire.
Installation
The product is intended for installation in a wall or ceiling, for connection to round ventilation ducts.
- Switch off the power supply. (Diagrams show disconnecting power and preparing the wall opening with wiring.)
- Remove the front cover from the product. (Diagram shows detaching the front cover.)
- Mark out and drill the mounting holes. (Diagrams illustrate marking and drilling holes in the wall.)
- Fasten the product with screws. (Diagrams show mounting the fan unit with screws and wall plugs, and the unit securely attached.)
- Connect the wires to the terminal block. (Diagram illustrates connecting electrical wires to the terminal block.)
- Connect the power supply.
Maintenance
- Switch off the power supply. (Diagram shows disconnecting power.)
- Remove the front cover. (Diagram depicts removing the front cover.)
- Clean the product with a cloth moistened with water and a mild detergent. (Diagram illustrates cleaning the main body with a damp cloth.)
- Clean the fan blades with a paintbrush. (Diagram shows cleaning fan blades using a brush.)
- Rinse the front grille under running water. Wipe the surface dry. (Diagram depicts rinsing the front grille and drying it.)
- Fit the front grille. (Diagram shows reattaching the front grille.)
- Connect the power supply.
NOTE: Make sure no water gets into the electrical components. Maintenance should be carried out at least once every 6 months.
Wiring Diagram Designations
- L: Live wire
- N: Neutral wire
- QF: Automatic fuse
- S: External power switch
Technical Data
Parameter | Value |
---|---|
Voltage | 230 V ~ 50 Hz |
Output | 14 W |
Flow | 98 m³/h |
Safety Class | II |
Protection Rating | IP34 |
Speed | 2300 rpm |
Noise Level | 34 dB |
Specific Energy Consumption (Cold/Medium/Hot) | -31 kWh/m² / -14 kWh/m² / -5 kWh/m² |
Annual Power Consumption (Cold/Medium/Hot) | 1 kWh / 1 kWh / 1 kWh |
Annual Savings of Primary Energy (Cold/Medium/Hot) | 34 kWh / 17 kWh / 8 kWh |